TY - JOUR T1 - Accuracy of ECG Chest Electrode Placements by Paramedics; an observational study JF - medRxiv DO - 10.1101/19001321 SP - 19001321 AU - Pete Gregory AU - Stephen Lodge AU - Tim Kilner AU - Suzy Paget Y1 - 2019/01/01 UR - http://medrxiv.org/content/early/2019/07/03/19001321.abstract N2 - Background The use of the 12-lead ECG is common in UK paramedic practice but its value depends upon accurate placement of the ECG-electrodes. Several studies have shown widespread variation in the placement of chest electrodes by other health professionals but no studies have addressed the accuracy of paramedics. The main objective of this study was to ascertain the accuracy of the chest lead placements by registered paramedics.Methods Registered paramedics who attended the Emergency Services Show in Birmingham in September 2018 were invited to participate in this observational study. Participants were asked to place the chest electrodes on a male model in accordance with their current practice. Correct positioning was determined against the Society for Cardiological Science & Technology’s Clinical Guidelines for recording a standard 12-lead electrocardiogram (2017) with a tolerance of 19mm being deemed acceptable based upon previous studies.Results 52 eligible participants completed the study. Measurement of electrode placement in the craniocaudal and mediolateral planes showed a high level of inaccuracy with 3/52 (5.8%) participants able to accurately place all chest leads. In leads V1 - V3, the majority of incorrect placements were related to vertical displacement with most participants able to identify the correct horizontal position. In V4, the tendency was to place the lead too low and to the left of the pre-determined position whilst V5 tended to be below the expected positioning but in the correct horizontal alignment. There was a less defined pattern of error in V6 although vertical displacement was more likely than horizontal displacement.Conclusions Our study identified a high level of variation in the placement of chest ECG electrodes which could alter the morphology of the ECG. From a patient safety perspective, we would advocate that paramedics leave the chest electrodes in situ to allow hospital staff to assess the accuracy of the placements.Key messages What is already known on this subjectThe recording of a prehospital ECG has become increasingly common in sophisticated Emergency Medical Services across the worldThe accuracy of precordial ECG electrode placement has been studied with other health professionals and has highlighted varying degrees of accuracy.Inaccurate electrode placement can lead to aberrant ECG readings and application of unnecessary treatment or the withholding of indicated treatmentWhat this study addsIn this observational cohort study, we found significant variation in the placement of the precordial ECG electrodes by UK registered paramedicsWe recommend that paramedics leave the prehospital ECG electrodes in situ to allow hospital staff to assess the accuracy of the placements.Competing Interest StatementThe authors have declared no competing interest.Funding StatementNo funding was received for this studyAuthor DeclarationsAll relevant ethical guidelines have been followed and any necessary IRB and/or ethics committee approvals have been obtained.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesAny clinical trials involved have been registered with an ICMJE-approved registry such as ClinicalTrials.gov and the trial ID is included in the manuscript.NAI have followed all appropriate research reporting guidelines and uploaded the relevant Equator, ICMJE or other checklist(s) as supplementary files, if applicable.YesThe data are deidentified participant data and will be available from Pete Gregory: pete.gregory{at}wlv.ac.uk. Data will be available immediately following publication and available for five years. The study protocol, consent forms and participant information sheets will also be made available on request. ER -