PT - JOURNAL ARTICLE AU - Vu, Jasmine AU - Bhusal, Bhumi AU - Rosenow, Joshua AU - Pilitsis, Julie AU - Golestanirad, Laleh TI - Surgical modification of deep brain stimulation lead trajectories substantially reduces RF heating during MRI at 3 T: From phantom experiments to clinical applications AID - 10.1101/2022.12.22.22283839 DP - 2022 Jan 01 TA - medRxiv PG - 2022.12.22.22283839 4099 - http://medrxiv.org/content/early/2022/12/27/2022.12.22.22283839.short 4100 - http://medrxiv.org/content/early/2022/12/27/2022.12.22.22283839.full AB - Introduction Radiofrequency (RF) induced tissue heating around deep brain stimulation (DBS) leads is a well-known safety risk during magnetic resonance imaging (MRI), resulting in strict imaging guidelines and limited allowable protocols. The implanted lead’s trajectory and its orientation with respect to the MRI electric fields contribute to variations in the magnitude of RF heating across patients. Currently, there are no consistent requirements for surgically implanting the extracranial portion of the DBS lead. This produces substantial variations in clinical DBS lead trajectories and hinders RF heating predictions. Recent studies showed that incorporating concentric loops in the extracranial trajectory of the lead can reduce RF heating, but the optimal positioning of the loop remains unknown. In this study, we systematically evaluated the RF heating of 244 unique lead trajectories to elucidate the characteristics of the trajectory that minimize RF heating during MRI at 3 T. We also presented the first surgical implementation of these modified trajectories and compared their RF heating to the RF heating of unmodified trajectories.Methods We performed phantom experiments to assess the maximum temperature increase, ΔTmax, of 244 unique lead trajectories. We systematically interrogated the effect of three characteristics related to the extracranial portion of the lead trajectory, namely, the number of concentric loops, the size of the loops, and the position of the loops on the skull. Experiments were performed in an anthropomorphic phantom implanted with a commercial DBS system, and RF exposure was generated by applying a high-SAR sequence (T1-weighted turbo spin echo dark fluid pulse sequence, B1+rms = 2.7 μT). Test-retest experiments were conducted to assess the reliability of measurements. Additionally, we determined the effect of imaging landmark and perturbations to the DBS device configuration on the efficacy of low-heating lead trajectories. Finally, recommended modified trajectories were implanted in patients by two neurosurgeons and their RF heating was characterized in comparison with non-modified trajectories.Results Our search protocol elicited lead trajectories with ΔTmax from 0.09 – 7.34 °C. Interestingly, increasing the number of loops and positioning them near the surgical burr hole—especially for the contralateral lead—substantially reduced RF heating. Trajectory specifications based on the results from the phantom experiments were easily adopted during the surgical procedure and generated nearly a 4-fold reduction in RF heating.Discussion/Conclusion Surgically modifying the extracranial portion of the DBS lead trajectory can substantially mitigate RF heating during MRI at 3 T. Simple adjustments to the lead’s configuration can be readily adopted during DBS lead implantation by implementing small concentric loops near the surgical burr hole.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis research study was supported by NIH Grant R01EB030324.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Ethics committees of Albany Medical Center and Northwestern University gave ethical approval for this workI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors