TY - JOUR T1 - Enhancing the sensitivity of rapid antigen detection test (RADT) of different SARS-CoV-2 variants and lineages using fluorescence-labeled antibodies and a fluorescent meter JF - medRxiv DO - 10.1101/2022.12.04.22283067 SP - 2022.12.04.22283067 AU - Gheyath K. Nasrallah AU - Fatma Ali AU - Salma Younes AU - Heba A. Al-Khatib AU - Asmaa A. Al-Thani AU - Hadi M. Yassine Y1 - 2022/01/01 UR - http://medrxiv.org/content/early/2022/12/05/2022.12.04.22283067.abstract N2 - RT-qPCR is considered the gold standard for diagnosis of COVID-19; however, it is laborious, time-consuming, and expensive. RADTs have evolved recently as relatively inexpensive methods to address these shortcomings, but their performance for detecting different SARS-COV-2 variants remains limited. RADT test performance could be enhanced using different antibody labeling and signal detection techniques. Here, we aimed to evaluate the performance of two Wondfo antigen RADTs for detecting different SARS-CoV-2 variants: (i) the conventional colorimetric RADT (Ab-conjugated with gold beads); and (ii) the new Finecare™ RADT (Ab-coated fluorescent beads). Finecare™ is a meter used for the detection of a fluorescent signal. 187 frozen nasopharyngeal swabs collected in Universal transport (UTM) that are RT-qPCR positive for different SARS-CoV-2 variants were selected, including 60 Alpha, 59 multiple Delta, and 108 multiple Omicron variants. 60 flu and 60 RSV-positive samples were included as negative controls (total sample number=349). The conventional RADT showed sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 62.4% (95%CI: 54-70), 100% (95%CI: 97-100), 100% (95%CI: 100-100), and 58% (95%CI: 49-67) respectively. These measurements were enhanced using the Finecare™ RADT: sensitivity, specificity, PPV, and NPV were 92.6% (95%CI: 89.08-92.3), 96% (95%CI: 96-99.61), 98% (95%CI: 89-92.3), and 85% (95%CI: 96-99.6) respectively. The sensitivity of both RADTs could be greatly underestimated because nasopharyngeal swab samples collected UTM and stored at −80 °C were used. Despite that, our results indicate that the Finecare™ RADT is appropriate for clinical laboratory and community-based surveillance due to its high sensitivity and specificity.Competing Interest StatementWe would like to declare that all RADT kits were provided by Wondfo as in-kind support to HMY and GKN labs.Funding StatementThis work was funded by REP29-026-3-004 grant from the Qatar National Research Fund (a member of Qatar Foundation).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:HMC-Institutional Review Board (HMC-IRB approval MRC-01-20-145) and QU-IRB (QU-IRB 1289-EA/20) gave ethical approval for this workI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present work are contained in the manuscript ER -