TY - JOUR T1 - Automated large-scale AMD progression prediction using machine-read OCT biomarkers JF - medRxiv DO - 10.1101/2022.08.21.22278906 SP - 2022.08.21.22278906 AU - Akos Rudas AU - Jeffrey N. Chiang AU - Giulia Corradetti AU - Nadav Rakocz AU - Eran Halperin AU - Srinivas R. Sadda Y1 - 2022/01/01 UR - http://medrxiv.org/content/early/2022/08/22/2022.08.21.22278906.abstract N2 - Age-related Macular Degeneration (AMD) is a major cause of irreversible vision loss in individuals over 55 years old in the United States. While anti-vascular growth factor injections can be used to treat macular neovascularization (MNV), there are currently no treatments available to halt or reverse geographic atrophy, which is the late-stage of nonneovascular AMD. There is a great interest in detecting early biomarkers associated with a higher risk for AMD progression in order to design early intervention clinical trials. The annotation of structural biomarkers on optical coherence tomography (OCT) B-scans is a laborious, complex and time-consuming process, and discrepancies between human graders can introduce variability into this assessment.To address this issue, a deep-learning model (SLIVER-net) was proposed, which could identify AMD biomarkers on structural OCT volumes with high precision and without human supervision. However, the validation was performed on a small dataset, and the true predictive power of these detected biomarkers in the context of a large cohort has not been evaluated. In this retrospective cohort study, we perform the largest-scale validation of these biomarkers to date. We also assess how these features combined with other EHR data (demographics, comorbidities, etc) affect and/or improve the prediction performance relative to known factors. Our hypothesis is that these biomarkers can be identified by a machine learning algorithm without human supervision, in a way that they preserve their predictive nature.The way we test this hypothesis is by building several machine learning models utilizing these machine-read biomarkers, and assessing their added predictive power. We found that not only can we show that the machine-read OCT B-scan biomarkers are predictive of AMD progression, we also observe that our proposed combined OCT and EHR data-based algorithm significantly outperforms the state-of-the-art solution in clinically relevant metrics and provides actionable information which has the potential to improve patient care. In addition, it provides a framework for automated large-scale processing of OCT volumes, making it possible to analyze vast archives without human supervision.Competing Interest StatementAkos Rudas: none Jeffrey N Chiang: none Giulia Corradetti: none Nadav Rakocz: none Eran Halperin: United Health Group (C) SriniVas Sadda: Amgen (C), Allergan (C), Genentech-Roche (C), Oxurion (C), Novartis (C), Regeneron (C), Iveric (C), 4DMT (C), Centervue (C, S), Heidelberg (C, F, S), Optos (C, F, S), Carl Zeiss Meditec (F, S), Nidek (S), Topcon (S)Funding StatementThe author(s) received no specific funding for this work.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The Institutional Review Board of University of California Los Angeles (UCLA IRB; IRB #15000083AM00056 Ocular Imaging Study; Doheny UCLA Eye Centers, Pasadena, California) gave ethical approval for this work.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe data are not publicly available due to institutional data use policy and concerns about patient privacy. The data set consists of 14,615 OCT volumes and corresponding electronic health record data collected from 4,182 patients in 2018 at Doheny UCLA Eye Centers. In order to apply for data access, please visit https://doheny.org or reach out to info{at}doheny.org. https://github.com/Pairas92/AMD-prediction https://doheny.org ER -