PT - JOURNAL ARTICLE AU - Ezequiel de la Rosa AU - Diana M. Sima AU - Jan S. Kirschke AU - Bjoern Menze AU - David Robben TI - Detecting CTP Truncation Artifacts in Acute Stroke Imaging from the Arterial Input and the Vascular Output Functions AID - 10.1101/2022.06.16.22276371 DP - 2022 Jan 01 TA - medRxiv PG - 2022.06.16.22276371 4099 - http://medrxiv.org/content/early/2022/06/21/2022.06.16.22276371.short 4100 - http://medrxiv.org/content/early/2022/06/21/2022.06.16.22276371.full AB - Background Current guidelines for CT perfusion (CTP) in acute stroke suggest acquiring scans with a minimal duration of 60-70 s. But even then, CTP analysis can be affected by truncation artifacts. Conversely, shorter acquisitions are still widely used in clinical practice and are usually sufficient to reliably estimate lesion volumes. We aim to devise an automatic method that detects scans affected by truncation artifacts.Methods Shorter scan durations are simulated from the ISLES’18 dataset by consecutively removing the last CTP time-point until reaching a 10 s duration. For each truncated series, perfusion lesion volumes are quantified and used to label the series as unreliable if the lesion volumes considerably deviate from the original untruncated ones. Afterwards, nine features from the arterial input function (AIF) and the vascular output function (VOF) are derived and used to fit machine-learning models with the goal of detecting unreliably truncated scans. Methods are compared against a baseline classifier solely based on the scan duration, which is the current clinical standard. The ROC-AUC, precision-recall AUC and the F1-score are measured in a 5-fold cross-validation setting.Results Machine learning models obtained high performance, with a ROC-AUC of 0.964 and precision-recall AUC of 0.958 for the best performing classifier. The highest detection rate is obtained with support vector machines (F1-score = 0.913). The most important feature is the AIFcoverage, measured as the time difference between the scan duration and the AIF peak. In comparison, the baseline classifier yielded a lower performance of 0.940 ROC-AUC and 0.933 precision-recall AUC. At the 60-second cutoff, the baseline classifier obtained a low detection of unreliably truncated scans (F1-Score = 0.638).Conclusions Machine learning models fed with discriminant AIF and VOF features accurately detected unreliable stroke lesion measurements due to insufficient acquisition duration. Unlike the 60s scan duration criterion, the devised models are robust to variable contrast injection and CTP acquisition protocols and could hence be used for quality assurance in CTP post-processing software.Competing Interest StatementEdlR, DMS and DR are employees of icometrix.Funding StatementThis project received funding from the European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement TRABIT No 765148.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Source data used in this work belongs to the open and public ISLES'18 challenge (http://www.isles-challenge.org/) [Cereda 2016, Hakim 2021]. As described in the dataset manuscript 'Ethics approval was obtained from the local institutional review board at each center'[Hakim 2021]. For our work, the dataset described in [Cereda 2016, Hakim 2021] has been downloaded after requesting access to the data through the repository mentioned in [Hakim 2021] (https://www.smir.ch/ISLES/Start2018). Besides, manual vascular function annotations used in our work have been already openly and freely published in [de la Rosa et al. 2021]. We accessed those annotations by directly downloading them from the journal supplementary material. References. Cereda, Carlo W., et al. "A benchmarking tool to evaluate computer tomography perfusion infarct core predictions against a DWI standard." Journal of Cerebral Blood Flow & Metabolism 36.10 (2016): 1780-1789. Hakim, Arsany, et al. "Predicting infarct core from computed tomography perfusion in acute ischemia with machine learning: lessons from the ISLES challenge." Stroke 52.7 (2021): 2328-2337. de la Rosa, Ezequiel, et al. "AIFNet: Automatic vascular function estimation for perfusion analysis using deep learning." Medical Image Analysis 74 (2021): 102211.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData produced in the present study is not available.