TY - JOUR T1 - Background noise in an Emergency Department: an observational study from staff and patient perspectives JF - medRxiv DO - 10.1101/2022.05.20.22275148 SP - 2022.05.20.22275148 AU - Murad Emar AU - Ella Smith AU - Timothy J Coats Y1 - 2022/01/01 UR - http://medrxiv.org/content/early/2022/05/21/2022.05.20.22275148.abstract N2 - Background and importance Noise is a contributing factor to mis-communication, poor sleep patterns and stress in healthcare. There has been little research on noise in the Emergency Department (ED).Objective(s) (1) To identify the noise levels experienced by staff and patients in different areas of an emergency department over the 24 hour cycle, (2) to examine the impact of cubicle doors on the background noise experienced by the patient, and (3) to assess the impact of monitor alarms on staff and patient noise levels.Design Observational study.Setting A large urban teaching hospital Emergency Department.Measures and analysis Using a standard protocol monitoring of staff and patient experience of noise was carried out in 3 areas of the ED (a resuscitation room, an area of patient cubicles with solid doors and and an area of patient cubicles with curtains).The overall distributions of noise levels in each area were described and circadian variation plotted. The proportion of time that background noise was above key cutoff values known to impair communication was calculated (45dB and 65dB).Non-parametric methods were used to compare: (1) a patient cubicle with curtains compared to a solid door, (2) having the door open or closed, and (3) staff and patient exposure a monitor alarm.Main results Noise was greater than 45dB for staff between 76% and 96% of the time (30% to 100% for patients). There was little difference across the 24hr cycle. A door decreased the noise experienced by patients, but only if left closed. In the resuscitation rooms monitor alarms were much louder for patients than for staff.Conclusion Noise levels likely to impair communication are present in the ED for most of the time. Staff awareness and improved design of both buildings and equipment might mitigate this negative acoustic environment.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study did not receive any fundingAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors. ER -