RT Journal Article SR Electronic T1 Direct estimates of absolute ventilation in primary health care clinics in South Africa JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2022.03.17.22272421 DO 10.1101/2022.03.17.22272421 A1 Peter G Beckwith A1 Aaron S Karat A1 Indira Govender A1 Arminder Deol A1 Nicky McCreesh A1 Karina Kielmann A1 Kathy Baisley A1 Alison D Grant A1 Tom A Yates YR 2022 UL http://medrxiv.org/content/early/2022/03/18/2022.03.17.22272421.abstract AB Background Healthcare facilities are important sites for the transmission of pathogens spread via bioaerosols, such as Mycobacterium tuberculosis (Mtb). Natural ventilation can play an important role in reducing this transmission. In primary health care (PHC) clinics in low and middle-income settings, susceptible people, including healthcare workers, are exposed to individuals with infectious pulmonary tuberculosis. We measured rates of natural ventilation in PHC clinics in KwaZulu-Natal and Western Cape provinces, South Africa.Methods and Findings We measured ventilation in clinic spaces using a tracer-gas release method. In spaces where this was not possible, we estimated ventilation using data on indoor and outdoor carbon dioxide levels, under reasonable assumptions about occupants’ metabolic rates. Ventilation was measured i) under usual conditions and ii) with all windows and doors fully open. We used these ventilation rates to estimate the risk of Mtb transmission using the Wells-Riley Equation. We obtained ventilation measurements in 33 clinical spaces in 10 clinics: 13 consultation rooms, 16 waiting areas and 4 other clinical spaces. Under usual conditions, the absolute ventilation rate was much higher in waiting rooms (median 1769 m3/hr, range 338–4815 m3/hr) than in consultation rooms (median 197 m3/hr, range 0–1451 m3/hr). Ventilation was better in permanent than in temporary structures. When compared with usual conditions, fully opening existing doors and windows resulted in a median two-fold increase in ventilation. Our Wells-Riley estimates show that, following sustained exposure, or contact with highly infectious index cases, some risk of Mtb infection may persist in the best ventilated clinical spaces unless other components of transmission risk are also addressed.Conclusions Among the clinical spaces studied, we observed substantial variation in natural ventilation. Ventilation interventions may have considerable impact on Mtb transmission in this setting. We recommend these form part of a package of infection prevention and control interventions.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThe Umoya Omuhle project is supported by the Economic and Social Research Council (UK). Grant reference: ES/P008011/1. The project is partly funded by the Antimicrobial Resistance Cross Council Initiative supported by the seven research councils in partnership with other funders including support from the Global Challenges Research Fund (GCRF). TAY was funded via an NIHR Academic Clinical Fellowship. NM is additionally funded by the Wellcome Trust (218261/Z/19/Z).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The Umoya omuhle study received ethical approval from the Biomedical Research Ethics Committee 207 of the University of KwaZulu-Natal (ref. BE082/18), the Human Research Ethics Committee of the 208 Faculty of Health Sciences of the University of Cape Town (ref. 165/2018), the Research Ethics 209 Committee of Queen Margaret University (ref. REP 0233), and the Observational/Interventions Research Ethics Committee of the London School of Hygiene & Tropical Medicine (ref. 14872). No data on individuals were captured for this aspect of the project. Consent to undertake these experiments was obtained from facility managers.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThis Stata code for the analysis of the tracer gas release experiments is available on GitHub (https://github.com/tayates/uo_ventilation). Analysis of paired indoor-outdoor CO2 measurements was carried out using R version 3.6.0 [29].This R code is also available on GitHub (URL:https://github.com/ArminderD/ventilation.git). The data are available via https://datacompass.lshtm.ac.uk/.