RT Journal Article SR Electronic T1 Detection of COVID-19 dysosmia with paired crushable odorant ampules JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2022.03.13.22271253 DO 10.1101/2022.03.13.22271253 A1 Ronald W. Wood A1 Christopher J Stodgell A1 Mitchell A. Linder A1 Eva K. Pressman YR 2022 UL http://medrxiv.org/content/early/2022/03/13/2022.03.13.22271253.abstract AB Background Signs of anosmia can help detect COVID-19 infection when testing for viral positivity is not available. Inexpensive mass-produced disposable olfactory sensitivity tests suitable for worldwide use might serve not only as a screening tool for potential infection but also to identify cases at elevated risk of severe disease as anosmic COVID-19 patients have a better prognosis.Methods and Findings We adopted paired crushable ampules with two concentrations of a standard test odorant (n-butanol) as standard of care in several clinics as community prevalence of COVID-19 infection waxed and waned. This was not a clinical trial; a chart review was undertaken to evaluate the operating characteristics and potential utility of the test device as RT-PCR testing became routine. The risk of anosmia was greater in COVID-19 patients. Olfactory sensitivity was concentration-dependent and decreased with aging. Hyposmia was detected across a wider age range than expected from the literature, and tests can be optimized to characterize different age groups.Conclusions n-Butanol at 0.32 and 3.2% in crushable ampules can be used to characterize olfactory function quickly and inexpensively and thus has potential benefits in pandemic screening, epidemiology, and clinical decision-making.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study did not receive any funding Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Chart review protocol was approved by the University of Rochester Research Subjects Review Board: Study00006033: Dysosmia Chart ReviewI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors