PT - JOURNAL ARTICLE AU - James Regan AU - James P. Flynn AU - Manish C. Choudhary AU - Rockib Uddin AU - Jacob Lemieux AU - Julie Boucau AU - Roby P. Bhattacharyya AU - Amy K. Barczak AU - Jonathan Z. Li AU - Mark J. Siedner TI - Detection of the omicron variant virus with the Abbott BinaxNow SARS-CoV-2 Rapid Antigen Assay AID - 10.1101/2021.12.22.21268219 DP - 2021 Jan 01 TA - medRxiv PG - 2021.12.22.21268219 4099 - http://medrxiv.org/content/early/2021/12/27/2021.12.22.21268219.short 4100 - http://medrxiv.org/content/early/2021/12/27/2021.12.22.21268219.full AB - The US Centers for Disease Control and Prevention recommends rapid testing for SARS-CoV-2 infection as a key element of epidemic control. The Abbott BinaxNow is in widespread use in the United States for self-testing and as part of public health screening campaigns, but has not been evaluated for use with the omicron variant of SARS-CoV-2. We recruited individuals testing positive for COVID-19 PCR at an academic medical center. Anterior nasal swabs were stored in viral transport media and evaluated by viral load quantification and whole genome sequencing. We created serial dilutions from 2.5×103-2.5×105 viral copies/specimen for two delta and omicron specimens, respectively, and tested each with the BinaxNow assay per manufacturer instructions. Results were interpreted by three readers, blinded to the specimen variant and concentration. All omicron and delta specimens with concentrations of 100,000 copies/swab or greater were positive by the BinaxNow Assay, a concentration similar to previously reported limits of detection for this assay. Assay sensitivity diminished below that. This study demonstrates that Omicron variant SARS-CoV-2 infections are detected by the BinaxNow rapid antigen assay. Additional laboratory and clinical validation assessments are needed to better determine their limits of detection and performance in real-world settings.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was supported by the Massachusetts Consortium on Pathogen ReadinessAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:IRB of MassGeneral Brigham gave ethical approval for this work.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors