TY - JOUR T1 - Fluid administration guided by inferior vena cava ultrasound before spinal anaesthesia may reduce post procedural hypotension rate JF - medRxiv DO - 10.1101/2021.06.20.21258944 SP - 2021.06.20.21258944 AU - Mathieu Favre AU - Samuele Ceruti AU - Maira Biggiogero AU - Michele Musiari AU - Andrea Glotta AU - Isabella Gimigliano AU - José Aguirre AU - Alain Borgeat AU - Andrea Saporito Y1 - 2021/01/01 UR - http://medrxiv.org/content/early/2021/06/22/2021.06.20.21258944.abstract N2 - PURPOSE This study was conducted to estimate the incidence of hypotension after spinal anaesthesia after inferior vena cava ultrasound (IVCUS) guided volaemic optimization compared with a control group in patients undergoing elective surgery. According to ESICM guidelines, hypotension was defined as two systolic arterial pressure (SAP) measurements < 80 mmHg and / or a mean arterial pressure (MAP) < 60 mmHg, or a drop in SAP of more than 50 mmHg or more than 25% from baseline, or a decrease in MAP by more than 30% from baseline and / or clinical signs/symptoms of inadequate perfusion.MATERIALS AND METHODS From May 2014 to February 2019, a prospective, controlled, randomised, three-arm, parallel-group trial was performed in our tertiary hospital. In the IVCUS group (I, 132 patients) and passive leg raising test group (L, 148 patients), a pre-anaesthesia volume optimization was achieved following a fluid response protocol. In control group (C, 149 patients), no specific intervention was performed.RESULTS 474 patients were collected. In group I, hypotension rate was 35%. In group L hypotension rate was 44%. In group C hypotension rate was 46%. An 11% reduction rate in hypotension (95% CI -1 to -24%, P=0.047) was observed between the group I and the group C. A 2% reduction rate in hypotension (95% CI -3 to -5%, P=0.428) was observed between group L and the group C. Total fluid amount administered was greater in the I group I than in the group C (593 ml versus 453 ml, P=0.015) and greater in the group L than the group C (511 ml versus 453 ml, P=0.11).CONCLUSION IVCUS guided fluid optimisation decrease the incidence of arterial hypotension after spinal anaesthesia.Competing Interest StatementThe authors have declared no competing interest.Clinical Trialwww.clinicaltrial.gov NCT02070276Funding StatementFinancial support and sponsorship: none.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Ethic Committees: Comitato Etico Cantonale, Via Orico 4, 6500 Bellinzona Ethical Approval was given with internal referral number CE2796 (Chairman G. M. Zanini)All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data are available under specific request ER -