%0 Journal Article %A Tanmay Dharmadhikari %A Vinay Rajput %A Rakeshkumar Yadav %A Radhika Boaragaonkar %A Dayanand Panse %A Sanjay Kamble %A Syed Dastager %A Mahesh Dharne %T High throughput sequencing based detection of SARS-CoV-2 prevailing in wastewater of Pune, West India %D 2021 %R 10.1101/2021.06.08.21258563 %J medRxiv %P 2021.06.08.21258563 %X Given a large number of SARS-CoV-2 infected individuals, clinical detection has proved challenging. The wastewater-based epidemiological paradigm would cover the clinically escaped asymptomatic individuals owing to the faecal shedding of the virus. We hypothesised using wastewater as a valuable resource for analysing SARS-CoV-2 mutations circulating in the wastewater of Pune region (Maharashtra; India), one of the most affected during the covid-19 pandemic. We conducted a case study in open wastewater drains from December 2020-March 2021 to assess the presence of SARS-CoV-2 nucleic acid and further detect mutations using ARTIC protocol of MinION sequencing. The analysis revealed 108 mutations across six samples categorised into 40 types of mutations. We report the occurrence of mutations associated with B.1.617 lineage in March-2021 samples, simultaneously also reported as a Variant of Concern (VoC) responsible for the rapid increase in infections. The study also revealed four mutations; S:N801, S:C480R, NSP14:C279F and NSP3:L550del not currently reported from wastewater or clinical data in India but reported in the world. Further, a novel mutation NSP13:G206F mapping to NSP13 region was observed from wastewater. Notably, S:P1140del mutation was observed in December 2020 samples while it was reported in February 2021 from clinical data, indicating the instrumentality of wastewater data in early detection. This is the first study in India to conclude that wastewater-based epidemiology to identify mutations associated with SARS-CoV-2 virus from wastewater as an early warning indicator system.Competing Interest StatementThe authors have declared no competing interest.Clinical TrialClinical trial not applicableFunding StatementThis project is funded by Science Engineering and Research Board (SERB), India under special covid grant (CVD/2020/001002).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The permissions regarding sample collection and processing were obtained from Pune Municipal Corporation, and Institutional Biosafety and Ethical Committee.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe amplicon sequenced SRA data is submitted to the NCBI database with accession number SRA:PRJNA728440. %U https://www.medrxiv.org/content/medrxiv/early/2021/06/09/2021.06.08.21258563.full.pdf