TY - JOUR T1 - Generalized Prediction of Hemodynamic Shock in Intensive Care Units JF - medRxiv DO - 10.1101/2021.01.07.21249121 SP - 2021.01.07.21249121 AU - Aditya Nagori AU - Pradeep Singh AU - Sameena Firdos AU - Vanshika Vats AU - Arushi Gupta AU - Harsh Bandhey AU - Anushtha Kalia AU - Arjun Sharma AU - Prakriti Ailavadi AU - Raghav Awasthi AU - Wrik Bhadra AU - Ayushmaan Kaul AU - Rakesh Lodha AU - Tavpritesh Sethi Y1 - 2021/01/01 UR - http://medrxiv.org/content/early/2021/05/31/2021.01.07.21249121.abstract N2 - Early prediction of hemodynamic shock in the ICU can save lives. Several studies have leveraged a combination of vitals, lab investigations, and clinical data to construct early warning systems for shock. However, these have a limited potential of generalization to diverse settings due to reliance on non-real-time data. Monitoring data from vitals can provide an early real-time prediction of Hemodynamic shock which can precede the clinical diagnosis to guide early therapy decisions. Generalization across age and geographical context is an unaddressed challenge. In this retrospective observational study, we built real-time shock prediction models generalized across age groups (adult and pediatric), ICU-types, and geographies. We developed generalizable models on publicly available eICU dataset, which is externally validated on cohorts derived from more than 0.23 million patient-hours of vitals data from a pediatric ICU in New Delhi and 1 million patient-hours vitals data from the adult ICU MIMIC-III database. Out of 208 hospitals data of eICU, we found 156 eligible for cohort building and split this data hospital-wise in a 5 fold training-validation-test set. Our model predicted hemodynamic shock 8 hours in advance with AUROC of 86 %(SD= 1.4) and AUPRC of 93% (SD =1.2). Our models identified 92% of all the shock events more than 8 hours in advance. Upon external validation on the MIMIC-III cohort, it achieved an AUROC of 87 %(SD =1.8), AUPRC 92 %(SD=1.6). External validation of our models on New Delhiā€™s Pediatric SafeICU data achieved an AUROC of 87 %(SD =4) AUPRC 91% (SD=3). Therefore, our models can guide early therapy decisions to save lives, reduce false alarms and address the generalizability gap. Our data and algorithms are publicly available as a pre-configured Docker environment at https://github.com/SAFE-ICU/ShoQPred.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was supported by the Wellcome Trust/DBT India Alliance Fellowship IA/CPHE/14/1/501504 awarded to Tavpritesh Sethi.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:"Datasets are de-identified and available for analysis as per the approval by MIT institutional review boards (IRBs) documented on the website http://physionet.org/. For SafeICU data ethical permission was granted by the All India Institute of Medical Sciences(AIIMS), New Delhi Institutional review board.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData is available on reasonable request to the corresponding author. ER -