PT - JOURNAL ARTICLE AU - Jung Hoon Lee AU - Max Rounds AU - Forbes McGain AU - Robyn Schofield AU - Grant Skidmore AU - Imogen Wadlow AU - Kevin Kevin AU - Ashley Stevens AU - Caroline Marshall AU - Lou Irving AU - Marion Kainer AU - Kirsty Buising AU - Jason Monty TI - Effectiveness of portable air filtration on reducing indoor aerosol counts: preclinical observational trials AID - 10.1101/2021.04.26.21256152 DP - 2021 Jan 01 TA - medRxiv PG - 2021.04.26.21256152 4099 - http://medrxiv.org/content/early/2021/04/28/2021.04.26.21256152.short 4100 - http://medrxiv.org/content/early/2021/04/28/2021.04.26.21256152.full AB - Objective To assess the effectiveness of aerosol filtration by portable air cleaning devices with high efficiency particulate air (HEPA) filters used in addition to standard building heating ventilation and air-conditioning (HVAC).Methods Test rooms, including a hospital single-patient room, were filled with test aerosol to simulate aerosol movement. Aerosol counts were measured over time with various portable air cleaning devices and room ventilation systems to quantify the aerosol concentration reduction rate and overall clearance rate.Results Portable air cleaners were very effective in removing aerosols, especially for the devices with high flow rate. In a small control room, the aerosols were cleared 4 to 5 times faster with portable air cleaners than the room with HVAC alone. A single bed hospital room equipped with an excellent ventilation rate (∼ 14 air changes per hour) can clear the aerosols in 20 minutes. However, with the addition of two air cleaners, the clearance time became 3 times faster (in 6 minutes and 30 seconds).Conclusions Portable air cleaning devices with HEPA filtration were highly effective at removing aerosols. To clear aerosols (above 90% clearance) in under 10 minutes requires around 25 air changes per hour; readily feasible with air cleaners. Inexpensive portable air cleaning devices should be considered for small and enclosed spaces in health care settings such as inpatient rooms, personal protective equipment donning/doffing stations, and staff tea rooms. Portable air cleaners are particularly important where there is limited ability to reduce aerosol transmission with building HVAC ventilation.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was funded by the University of MelbourneAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Office of Research Ethics and Integrity, The University of Melbourne.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe datasets used in the current study were collected by the researchers at the University of Melbourne