RT Journal Article SR Electronic T1 Predicting and simulating effects of PEEP changes with machine learning JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2021.01.28.21250212 DO 10.1101/2021.01.28.21250212 A1 Claas Strodthoff A1 Inéz Frerichs A1 Norbert Weiler A1 Björn Bergh YR 2021 UL http://medrxiv.org/content/early/2021/01/31/2021.01.28.21250212.abstract AB Background/Objectives Choosing ventilator settings, especially positive end-expiratory pressure (PEEP), is a very common and non-trivial task in intensive care units (ICUs). Established solutions to this problem are either poorly individualised or come with high costs in terms of used material or time. We propose a novel method relying on machine learning utilising only already routinely measured data.Methods Using the MIMIC-III (with over 60000 ICU stays) and eICU databases (with over 200000 ICU stays) we built a deep learning model that predicts relevant success parameters of ventilation (oxygenation, carbon dioxide elimination and respiratory mechanics). We compare a random forest, individual neural networks and a multi-tasking neural network. Our final model also allows to simulate the expected effects of PEEP changes.Results The model predicts arterial partial pressures of oxygen and carbon dioxide and respiratory system compliance 30 minutes into the future with mean absolute percentage errors of about 22 %, 10 % and 11 %, respectively.Conclusions The deep learning approach to ventilation optimisation is promising and comes with low cost compared to other approaches.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThere is no financial funding or interest to report.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:MIMIC-III: The project was approved by the Institutional Review Boards of Beth Israel Deaconess Medical Center (Boston, MA) and the Massachusetts Institute of Technology (Cambridge, MA). eICU: The database is released under the Health Insurance Portability and Accountability Act (HIPAA) safe harbor provision. The re-identification risk was certified as meeting safe harbor standards by Privacert (Cambridge, MA) (HIPAA Certification no. 1031219-2).All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).Yes I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesDatasets are used from the collection of eICU Collaborative Research Database and Medical Information Mart for Intensive Care III. We passed the Protecting Human Research Participants exam and obtained permission to access the dataset. Access to the data (via physionet) was granted after registration on Oct. 23, 2019, 3:47 p.m. Necessary Agreements were signed: Nov. 7, 2019 PhysioNet Credentialed Health Data Use Agreement 1.5.0 eICU Collaborative Research Database (v2.0); Oct. 24, 2019 PhysioNet Credentialed Health Data Use Agreement 1.5.0 MIMIC-III Clinical Database (v1.4) https://eicu-crd.mit.edu/ https://mimic.physionet.org/