TY - JOUR T1 - Covid-19 respiratory protection: the filtration efficiency assessment of decontaminated FFP2 masks responding to associated shortages JF - medRxiv DO - 10.1101/2021.01.18.21249976 SP - 2021.01.18.21249976 AU - M. Benboubker AU - B. Oumokhtar AU - F. Hmami AU - K. El Mabrouk AU - L.EL Alami AU - B. Arhoune AU - M F. Belahsen AU - A. Aboutajeddine Y1 - 2021/01/01 UR - http://medrxiv.org/content/early/2021/01/20/2021.01.18.21249976.abstract N2 - During the Covid-19 pandemic, healthcare workers were extremely vulnerable to infection with the virus and needed continuous protection. One of the most effective and widely used means of protection was the FFP2 respirator. Unfortunately, this crisis created a shortage of these masks, prompting hospitals to explore opportunities to reuse them after decontamination.An approach for assessing the filtration efficiency of decontaminated FFP2 masks has been proposed and applied to evaluate the possibilities of their safe reuse. The decontamination processes adopted are those based on moist heat or hydrogen peroxide. The approach introduces efficiency measures that define the filtration and protection capacity of the masks, which characterize both chemical and structural changes, and encompasses many techniques including scanning electron microscopy (SEM), Fourier transforms infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA). The test protocol was applied to mask samples that had endured different decontamination cycles and the results of their efficiency measures were compared to brand-new masks’ performances.The main result was that chemical and structural characterization of the decontaminated masks have shown no substantial change or deformation of their filter media structures. Indeed, the respiratory resistance test has shown that the results of both the FFP2 masks that have undergone a hydrogen peroxide disinfection cycle or a steam autoclave cycle remained constant with a small variation of 10 Pa from the EN149 standard. The chemical characterization, on the other hand, has shown that the filter media of the decontaminated masks remains unchanged, with no detectable chemical derivatives in its constituents.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis research has not received any specific grants from funding agencies in the public, commercial, or not for profit sectors.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Ethics Committee of the University Hospital of Fez comite.ethique.fes{at}usmba.ac.maAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.Yesno data available ER -