RT Journal Article SR Electronic T1 Addressing Personal Protective Equipment (PPE) Decontamination: Methylene Blue and Light Inactivates SARS-CoV-2 on N95 Respirators and Masks with Maintenance of Integrity and Fit JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.12.11.20236919 DO 10.1101/2020.12.11.20236919 A1 Thomas S. Lendvay A1 James Chen A1 Brian H. Harcourt A1 Florine E.M. Scholte A1 F. Selcen Kilinc-Balci A1 Ying Ling Lin A1 Molly M. Lamb A1 Larry F. Chu A1 Amy Price A1 David Evans A1 Yi-Chan Lin A1 Christopher N. Mores A1 Jaya Sahni A1 Kareem B. Kabra A1 Eric Haubruge A1 Etienne Thiry A1 Belinda Heyne A1 Jan Laperre A1 Sarah Simmons A1 Jan M. Davies A1 Yi Cui A1 Thor Wagner A1 Tanner Clark A1 Sarah J. Smit A1 Rod Parker A1 Thomas Gallagher A1 Emily Timm A1 Louisa F. Ludwig-Begall A1 Nicolas Macia A1 Cyrus Mackie A1 Karen Hope A1 Ken Page A1 Susan Reader A1 Peter Faris A1 Olivier Jolois A1 Alpa Patel A1 Jean-Luc Lemyre A1 Vanessa Molloy-Simard A1 Kamonthip Homdayjanakul A1 Sarah R. Tritsch A1 Constance Wielick A1 Mark Mayo A1 Rebecca Malott A1 Jean-Francois Willaert A1 Hans Nauwynck A1 Lorène Dams A1 Simon De Jaeger A1 Lei Liao A1 Mervin Zhao A1 Steven Chu A1 John M. Conly A1 May C. Chu YR 2020 UL http://medrxiv.org/content/early/2020/12/12/2020.12.11.20236919.abstract AB Background The coronavirus disease 2019 (COVID-19) pandemic has resulted in severe shortages of personal protective equipment (PPE) necessary to protect front-line healthcare personnel. These shortages underscore the urgent need for simple, efficient, and inexpensive methods to decontaminate SARS-CoV-2-exposed PPE enabling safe reuse of masks and respirators. Efficient decontamination must be available not only in low-resourced settings, but also in well-resourced settings affected by PPE shortages. Methylene blue (MB) photochemical treatment, hitherto with many clinical applications including those used to inactivate virus in plasma, presents a novel approach for widely applicable PPE decontamination. Dry heat (DH) treatment is another potential low-cost decontamination method.Methods MB and light (MBL) and DH treatments were used to inactivate coronavirus on respirator and mask material. We tested three N95 filtering facepiece respirators (FFRs), two medical masks (MMs), and one cloth community mask (CM). FFR/MM/CM materials were inoculated with SARS-CoV-2 (a Betacoronavirus), murine hepatitis virus (MHV) (a Betacoronavirus), or porcine respiratory coronavirus (PRCV) (an Alphacoronavirus), and treated with 10 µM MB followed by 50,000 lux of broad-spectrum light or 12,500 lux of red light for 30 minutes, or with 75°C DH for 60 minutes. In parallel, we tested respirator and mask integrity using several standard methods and compared to the FDA-authorized vaporized hydrogen peroxide plus ozone (VHP+O3) decontamination method. Intact FFRs/MMs/CM were subjected to five cycles of decontamination (5CD) to assess integrity using International Standardization Organization (ISO), American Society for Testing and Materials (ASTM) International, National Institute for Occupational Safety and Health (NIOSH), and Occupational Safety and Health Administration (OSHA) test methods.Findings Overall, MBL robustly and consistently inactivated all three coronaviruses with at least a 4-log reduction. DH yielded similar results, with the exception of MHV, which was only reduced by 2-log after treatment. FFR/MM integrity was maintained for 5 cycles of MBL or DH treatment, whereas one FFR failed after 5 cycles of VHP+O3. Baseline performance for the CM was variable, but reduction of integrity was minimal.Interpretation Methylene blue with light and DH treatment decontaminated masks and respirators by inactivating three tested coronaviruses without compromising integrity through 5CD. MBL decontamination of masks is effective, low-cost and does not require specialized equipment, making it applicable in all-resource settings. These attractive features support the utilization and continued development of this novel PPE decontamination method.Competing Interest StatementAuthors Thomas S. Lendvay, James Chen are Co-Founders and equity owners of Singletto, Inc. (Seattle, WA, USA) Authors Yi Cui and Steven Chu are Co-Founders and equity owners of 4C Air, Inc. (Sunnyvale, CA)Funding StatementThis study was funded by Open Philanthropy; Amazon Inc./University of Washington Catalyst Award; University of Liege (Belgium) and the Walloon Region, Belgium; Li Ka Shing Institute; Alberta Health Services; and an Anonymous donor to the University of Washington, Department of Urology.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Stanford University and Alberta Health Services/University of Calgary were exempt from IRB as the human fit testing was considered Quality Improvement. ERB for clinical specimen use: A clinical saliva specimen with a SARS-CoV-2 was provided by Dr. John Conly from Calgary, Alberta with Calgary ERB approval (ID# Pro00099761).All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).Yes I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData will be freely shared post publication on reasonable request by contacting the corresponding author of the study.