%0 Journal Article %A Brett A. Meyers %A Melissa C. Brindise %A R. Mark Payne %A Pavlos P. Vlachos %T An Integrated and Automated Tool for Quantification of Biomechanics in Fetal and Neonatal Echocardiography %D 2020 %R 10.1101/2020.10.21.20217265 %J medRxiv %P 2020.10.21.20217265 %X Objectives To show simultaneous quantification of flow and mechanics of cardiac function from fetal and neonatal echocardiograms using an integrated set of automated, physics-based, echocardiography analysis methods.Background Quantifying ventricular biomechanics from fetal and neonatal echocardiograms presents unique and significant challenges. Existing analysis tools are designed for adults and cannot accurately assess fetal subjects.Methods We used in-house developed analysis algorithms to quantify ventricular biomechanics from four-chamber B-mode and color Doppler routine examinations recordings for three hypoplastic left heart (HLHS) patients at 33-weeks’ gestation and first week post-birth along with age-matched controls. Chamber morphology, tissue motion, atrioventricular valve inflow, global longitudinal strain, and hemodynamic flow parameters were measured.Results Prenatal cardiac output differed between control (LV:157 ± 139 mL/min, RV:257 ± 218 mL/min) and HLHS subjects (410 ± 128 mL/min). This difference persisted for control (LV:233 ± 74 mL/min, RV:242 ± 140 mL/min) and HLHS subjects (637 ± 298 mL/min) after birth. Peak global longitudinal strain measurements did not differ in utero between control (LV: 12.2 ± 4.1%, RV:12.1 ± 4.9%) and HLHS subjects (RV:12.7± 4.2%). After birth, myocardial contraction increased for the control (LV:15.4 ± 2.8%, RV:22.9 ± 6.9%) and HLHS subjects (14.4 ± 6.2%). Postnatal early filling mitral flow velocity for the control subjects (LV:58.8 ± 17.6 cm/s) and early-filling tricuspid flow of the HLHS subjects (64.8 ± 23.7cm/s) were similar, while the late filling velocity decreased for the control subject LV (33.5 ± 8.1 cm/s) compared to the HLHS subjects (66.9 ± 23.0 cm/s). Importantly, flow energy loss in the fetal HLHS hearts was increased (0.35 ± 0.19 m3/s2) compared to the control subjects (LV:0.09 ± 0.07 m3/s2, RV:0.17 ± 0.12 m3/s2), and further increased postnatally for the HLHS subjects (0.55 ± 0.24 m3/s2) compared to the control subjects (LV:0.23 ± 0.20 m3/s2, RV:0.09 ± 0.06 m3/s2).Conclusions We demonstrate the feasibility of integrated quantitative measurements of fetal and neonatal ventricular hemodynamics and biomechanics using only four-chamber B-mode and color Doppler recordings.Short Abstract We integrated novel echocardiogram analysis methods to quantify ventricular flow and mechanics using apical long-axis B-mode and color Doppler imaging from fetal and neonatal subjects. Three hypoplastic left heart patients (HLHS) imaged at 33-weeks gestation and again in the first postnatal week, along with age-matched controls, were evaluated. For the first time, we show quantified hemodynamics from fetal echocardiography using flow reconstruction, flow energy loss, and intraventricular pressure, as well as global strain and strain rate. These tools are capable of longitudinal analysis of ventricle maturation, flow dynamics, and quantified measurements from routine examinations of complex congenital heart disease.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis project was supported, in part, by the Indiana Clinical and Translational Sciences Institute funded, in part, by Grant Number UL1TR002529 from the National Institutes of Health, National Center for Advancing Translational Sciences, Clinical and Translational Sciences Award. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. No industry partnerships collaborated on or funded this work.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The Institutional Review Board for Human Studies for Purdue and Indiana universities approved the study.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).Yes I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData will be made available upon request.AVAtrioventricularALAXApical long axisCHDCongenital Heart DiseaseCFIcolor flow imagingCOCardiac outputECGElectrocardiogramELEnergy lossHLHSHypoplastic Left Heart SyndromeGLSGlobal Longitudinal StrainGLSrGlobal Longitudinal Strain RateLVLeft ventricleRVRight ventricleVSVortex strengthSVStroke volumeΔPPressure difference %U https://www.medrxiv.org/content/medrxiv/early/2020/10/25/2020.10.21.20217265.full.pdf