Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Quantitative Shape Analysis Supports the Use of Aortic Arch Stent Grafts in Complex Aortic Geometries

View ORCID ProfileKelly C. Twohig, Joseph A. Pugar, Ian McDougall, Cheong Jun Lee, Ross Milner, Luka Pocivavsek
doi: https://doi.org/10.64898/2026.10.25.26365919
Kelly C. Twohig
1Department of Surgery, University of Chicago, Chicago, IL
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Kelly C. Twohig
  • For correspondence: Kelly.twohig{at}uchicagomedicine.org
Joseph A. Pugar
2Section of Vascular Surgery and Endovascular Therapy, University of Chicago, Chicago, IL
PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ian McDougall
3Endospan Ltd., Herzliya, Israel
BS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Cheong Jun Lee
4Section of Vascular Surgery, Endeavor Health Medical Group, Evanston, IL
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ross Milner
2Section of Vascular Surgery and Endovascular Therapy, University of Chicago, Chicago, IL
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Luka Pocivavsek
2Section of Vascular Surgery and Endovascular Therapy, University of Chicago, Chicago, IL
MD, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Introduction Traditional thoracic endovascular aortic repair (TEVAR) relies on distal landing zones beyond the left common carotid artery, which may underperform in patients with complex aortic anatomy. The Nexus Aortic Arch Stent Graft enables proximal landing zones in the ascending aorta, expanding endovascular options for challenging arch pathology. This study applies a geometrically focused framework using fluctuation in total integrated Gaussian curvature (δK), a size-invariant metric of surface topology, to evaluate Nexus performance across diverse aortic morphologies.

Methods Pre-operative CT imaging was analyzed for 27 patients treated with the Nexus device and 37 treated with traditional TEVAR (proximal landing zones 2/3). CT scans from 215 patients with non-pathologic aortas served as controls. Two-dimensional aortic surface meshes were constructed to calculate δK and mean aortic radius, while tortuosity index was derived from the centerline. Nexus data were mapped into a previously established size-shape feature space to assess predicted outcomes. TEVAR failure was defined as reintervention or death due to aneurysmal growth, endoleak, dissection extension, or rupture. Correlation and clustering analyses evaluated relationships between aortic morphology and outcomes. A scale-sampling approach captured the multiscale nature of aortic geometry while reducing sensitivity to mesh resolution and partitioning.

Results The Traditional TEVAR cohort had a significantly lower success rate than the Nexus cohort (51.4% vs. 85.2%, p = 0.005). Traditional TEVAR was particularly less effective in patients with elevated δK and large mean radius, whereas the Nexus device demonstrated favorable outcomes even in anatomically complex aortas with similarly elevated δK and radius values. Combining δK and radius demonstrated distinct clustering patterns by pathology: 78.3% of chronic dissections occupied the high δK/radius zone, while 70.6% of isolated aneurysms fell in the low δK/radius zone (p <0.001). δK provided unique morphological insight beyond size, whereas tortuosity index was less discriminative.

Conclusion δK offers a quantitative framework for assessing device performance across variable aortic anatomy. Endovascular arch repair using proximal ascending aortic landing zones, exemplified by the Nexus device, may provide a viable option in patients with complex geometry. This shape-size framework represents a step toward personalized patient selection and improved long-term outcomes.

Competing Interest Statement

Luka Pocivavsek reports financial support was provided by National Heart Lung and Blood Institute. Ian McDougall reports a relationship with Endospan, Ltd. that includes: employment and equity or stocks. Ross Milner reports a relationship with Endospan, Ltd. that includes: consulting or advisory. Endospan, Ltd., provided the data for analysis and helped in providing context of our findings within their prior published trial results. There was no direct financial support for this project from Endospan.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

IRB of University of Chicago gave ethical approval for this work

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

All data produced in the present study are available upon reasonable request to the authors

Funder Information Declared

National Heart Lung and Blood Institute, https://ror.org/012pb6c26, R01HL159205
Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted October 28, 2026.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Quantitative Shape Analysis Supports the Use of Aortic Arch Stent Grafts in Complex Aortic Geometries
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Quantitative Shape Analysis Supports the Use of Aortic Arch Stent Grafts in Complex Aortic Geometries
Kelly C. Twohig, Joseph A. Pugar, Ian McDougall, Cheong Jun Lee, Ross Milner, Luka Pocivavsek
medRxiv 2026.10.25.26365919; doi: https://doi.org/10.64898/2026.10.25.26365919
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Quantitative Shape Analysis Supports the Use of Aortic Arch Stent Grafts in Complex Aortic Geometries
Kelly C. Twohig, Joseph A. Pugar, Ian McDougall, Cheong Jun Lee, Ross Milner, Luka Pocivavsek
medRxiv 2026.10.25.26365919; doi: https://doi.org/10.64898/2026.10.25.26365919

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Surgery
Subject Areas
All Articles
  • Addiction Medicine (638)
  • Allergy and Immunology (917)
  • Anesthesia (350)
  • Cardiovascular Medicine (4999)
  • Dentistry and Oral Medicine (494)
  • Dermatology (427)
  • Emergency Medicine (676)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (1690)
  • Epidemiology (16253)
  • Forensic Medicine (36)
  • Gastroenterology (1241)
  • Genetic and Genomic Medicine (7274)
  • Geriatric Medicine (751)
  • Health Economics (1093)
  • Health Informatics (5283)
  • Health Policy (1467)
  • Health Systems and Quality Improvement (1832)
  • Hematology (599)
  • HIV/AIDS (1380)
  • Infectious Diseases (except HIV/AIDS) (16483)
  • Intensive Care and Critical Care Medicine (1203)
  • Medical Education (700)
  • Medical Ethics (156)
  • Nephrology (751)
  • Neurology (7586)
  • Nursing (377)
  • Nutrition (1127)
  • Obstetrics and Gynecology (1295)
  • Occupational and Environmental Health (1039)
  • Oncology (3742)
  • Ophthalmology (1092)
  • Orthopedics (408)
  • Otolaryngology (465)
  • Pain Medicine (501)
  • Palliative Medicine (143)
  • Pathology (721)
  • Pediatrics (1858)
  • Pharmacology and Therapeutics (755)
  • Primary Care Research (786)
  • Psychiatry and Clinical Psychology (6122)
  • Public and Global Health (9984)
  • Radiology and Imaging (2528)
  • Rehabilitation Medicine and Physical Therapy (1516)
  • Respiratory Medicine (1268)
  • Rheumatology (658)
  • Sexual and Reproductive Health (804)
  • Sports Medicine (595)
  • Surgery (802)
  • Toxicology (109)
  • Transplantation (318)
  • Urology (307)