Abstract
Background The Simplified Geneva Score (SGS) incorporates two heart-rate thresholds. Multiple heart-rate measurements are commonly recorded during emergency department (ED) assessment. While the original SGS specifies use of mean heart rate, real-world implementation is unlikely to reflect this, and the effect of alternative heart-rate selection methods on score performance is unknown.
Methods SCORES was a retrospective within-subject study of consecutive ED patients at a single urban hospital undergoing computed tomography pulmonary angiography (CTPA) for suspected pulmonary embolism (PE). Four SGS variants were calculated using the first, highest, mean, and lowest recorded pre-CTPA heart rate. Outcomes included score output, risk classification, diagnostic performance, reclassification flow, and downstream imaging utilisation. Precision estimates and comparisons were derived using empirical resampling techniques.
Results 590 episodes were reviewed with 581 included for analysis. PE was confirmed in 50 cases (8.6%). Mean SGS differed significantly across all heart-rate implementations (p<0.0001). The proportion classified as high risk varied from 15% using the lowest heart rate to 40% using the highest heart rate. Reclassification across the SGS threshold was common, with 25% of episodes changing risk category unidirectionally between lowest and highest heart rate implementations. SGS(lowest HR) compared with SGS(mean HR) and SGS(highest HR) demonstrated higher specificity (87.6% vs 73.4% vs 62.1%), improved AUROC (0.744 vs 0.704 vs 0.659), and reduced downstream CTPA utilisation (818 vs 876 vs 920 scans per 100 PEs diagnosed), with no additional pulmonary emboli missed within the complete diagnostic pathway.
Conclusions Heart-rate selection materially influences SGS output, risk classification, diagnostic performance, and imaging utilisation. In this retrospective cohort, use of the lowest recorded heart rate produced the most favourable overall balance of discrimination and diagnostic efficiency, supporting prospective validation.
Competing Interest Statement
The authors have declared no competing interest.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The ACT (Australian Capital Territory) Human Research Ethics Committee (HREC) of ACT Health gave ethical approval for this work, including a Waiver of Consent (for the secondary use of de-identified data). Reference 2025/ETH02245.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Footnotes
Revision for formatting errors, and addition of brief patient & public involvement statement.
Data Availability
All de-identified data produced in the present study can be made available upon reasonable request to the author, in consultation with the ACT HREC.