A calibration pipeline for controlled ocular photostimulation with consumer see-through extended-reality glasses

View ORCID ProfileMatt Gaidica, View ORCID ProfileMatthew Rosengart
doi: https://doi.org/10.64898/2026.08.26.26361398
Matt Gaidica
1Department of Neuroscience, Washington University School of Medicine, St. Louis, MO, USA
PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Matt Gaidica
  • For correspondence: gaidica{at}wustl.edu
Matthew Rosengart
2Department of Surgery, Washington University School of Medicine, St. Louis, MO, USA
MD, MPH
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Matthew Rosengart
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Consumer extended-reality (XR) glasses could provide controlled ocular light exposure, but their settings do not specify the light delivered at the eye. We developed and validated a calibration pipeline linking display control, corneal-plane spectroradiometry, settings-to-exposure modeling, and rendered application content for a see-through binocular micro-OLED display (VITURE Luma Ultra). Automated measurements characterized color channels, digital codes, hardware brightness levels, and duty-cycle settings across repeated fittings on a phantom head. The blue primary peaked at 459 nm with no resolved spectral shift across intensity settings. Blue melanopic equivalent daylight illuminance (EDI) ranged from 14.7 to 252 lx across hardware brightness levels, while full white delivered 269 lx melanopic EDI at its highest usable setting, exceeding the 250 lx daytime recommendation for healthy adults. A model calibrated on separate sessions predicted melanopic EDI for held-out codes, brightness levels, and color mixtures with a mean absolute percentage error of 3.4% (4.5% for photopic illuminance), allowing exposure to be estimated from logged display settings without remeasuring each uniform stimulus. Rendered application frames revealed position- and illuminated-area-dependent exposure; a spatial correction derived from an independent display grid accounted for these effects and closely reproduced measured frame exposure. Together, these results establish a reusable workflow for converting see-through XR hardware into a quantitatively specified ocular-light platform.

Competing Interest Statement

M.G. was previously a founder of Gamma Light Therapy LLC, a consumer light-therapy company, and holds no current financial or advisory interest in the company. The authors declare no other competing interests.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Footnotes

  • This revision replaces the measurement chain of v1 (posted August 31, 2026) and broadens the manuscript from a single-device dose characterization to a reusable calibration workflow, now titled "A calibration pipeline for controlled ocular photostimulation with consumer see-through extended-reality glasses." The open-source miniature spectroradiometer and its smartphone-anchored luminance transfer calibration (10 to 20% absolute uncertainty) have been replaced by a factory-calibrated, cosine-corrected spectroradiometer (UPRtek MK350S) at the corneal plane of a phantom head. All values are therefore reported as corneal-plane exposure, the quantity used by CIE S 026 and the consensus recommendations, and the model-eye retinal dose estimates have been removed. Characterization was repeated over three sessions with the glasses reseated between them, and repeatability is reported within captures, within sessions, and between sessions. Duty cycle, which v1 only logged, is now characterized as a third independent intensity control. Several values changed with the new measurements: the blue primary peaks at 459 nm with a FWHM of 34.7 nm (v1: 461 nm and 43 nm); full-code blue delivers 252 lx melanopic EDI (v1: 299 lx); the red melanopic DER is 0.018 (v1: 0.10); white reaches 81 to 89% of the sum of its primaries and cannot be run at the top brightness level; and the blue-light hazard of full-code blue is about a factor of 3 below the conservative small-source screening criterion. Two analyses are new. First, a settings-to-exposure model, calibrated on separate sessions and tested on an independent held-out session, predicts melanopic EDI and photopic illuminance from code, brightness level, and duty cycle with mean absolute percentage errors of 3.4% and 4.5%, and is released as a versioned calibration package. Second, rendered application frames showed that exposure depends on where pixels are and how much of the display is lit, and a spatial correction derived from an independent 3×3 display grid substantially improved agreement with measured frame exposure. Finally, the gate-based structure was replaced by a control, measure, calibrate, validate, and apply framing; terminology was clarified for non-specialist readers; figures were restructured; reference tables were moved to appendices; and the future-work list became a Scope and limitations section.

Data Availability

All data produced in the present study are available upon reasonable request to the authors.

https://github.com/mattgaidica/XR-Glasses-Characterization

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted October 13, 2026.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
A calibration pipeline for controlled ocular photostimulation with consumer see-through extended-reality glasses
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
A calibration pipeline for controlled ocular photostimulation with consumer see-through extended-reality glasses
Matt Gaidica, Matthew Rosengart
medRxiv 2026.08.26.26361398; doi: https://doi.org/10.64898/2026.08.26.26361398
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
A calibration pipeline for controlled ocular photostimulation with consumer see-through extended-reality glasses
Matt Gaidica, Matthew Rosengart
medRxiv 2026.08.26.26361398; doi: https://doi.org/10.64898/2026.08.26.26361398

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Ophthalmology
Subject Areas
All Articles
  • Addiction Medicine (638)
  • Allergy and Immunology (917)
  • Anesthesia (350)
  • Cardiovascular Medicine (5000)
  • Dentistry and Oral Medicine (495)
  • Dermatology (428)
  • Emergency Medicine (676)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (1690)
  • Epidemiology (16253)
  • Forensic Medicine (36)
  • Gastroenterology (1241)
  • Genetic and Genomic Medicine (7274)
  • Geriatric Medicine (751)
  • Health Economics (1093)
  • Health Informatics (5284)
  • Health Policy (1467)
  • Health Systems and Quality Improvement (1832)
  • Hematology (599)
  • HIV/AIDS (1381)
  • Infectious Diseases (except HIV/AIDS) (16484)
  • Intensive Care and Critical Care Medicine (1203)
  • Medical Education (700)
  • Medical Ethics (156)
  • Nephrology (751)
  • Neurology (7586)
  • Nursing (377)
  • Nutrition (1129)
  • Obstetrics and Gynecology (1295)
  • Occupational and Environmental Health (1040)
  • Oncology (3742)
  • Ophthalmology (1093)
  • Orthopedics (409)
  • Otolaryngology (465)
  • Pain Medicine (501)
  • Palliative Medicine (143)
  • Pathology (721)
  • Pediatrics (1858)
  • Pharmacology and Therapeutics (755)
  • Primary Care Research (786)
  • Psychiatry and Clinical Psychology (6124)
  • Public and Global Health (9986)
  • Radiology and Imaging (2529)
  • Rehabilitation Medicine and Physical Therapy (1516)
  • Respiratory Medicine (1268)
  • Rheumatology (658)
  • Sexual and Reproductive Health (804)
  • Sports Medicine (595)
  • Surgery (803)
  • Toxicology (109)
  • Transplantation (318)
  • Urology (307)