Amyotrophic lateral sclerosis (ALS) lacks a validated blood-based diagnostic, and the field is increasingly moving from single-molecule markers toward integrative, multi-component signatures. Here we present a liquid-biopsy strategy that transduces disease-dependent serum–nanoparticle interactions into a learnable near-infrared spectral phenotype. A sensor array of twelve DNA-functionalized single-walled carbon nanotube (SWCNT) chiralities, functionalized with (GT)6 ssDNA coupled with a deep learning model was tested on serum from 20 ALS patients and 19 age- and sex-matched controls (n = 39, TargetALS). Our multiplexed sensor design (12 SWCNT chiralities) and data acquisition strategy based on excitation–emission matrices acquired at three timepoints (0, 6, 24 h) was conceived to maximize sensor carried information. Indeed, we show that the array generates partially independent temporal dynamics across chiralities governed primarily by tube diameter. To decode this multiplexed, time-resolved signal, we trained a dual-objective convolutional autoencoder that jointly optimizes reconstruction and classification, achieving 84.6% cross-validated accuracy (AUC = 0.87). Selected latent features were reproducible across an independent same-subject experimental batch and correlated with serum neurofilament light chain, linking the spectral phenotype to a clinically relevant neurodegeneration marker. Mass spectrometry supported a molecular basis for discrimination, revealing an ALS-biased protein corona enriched in adaptive-immune and inflammatory proteins. Together, these results establish proof of principle that time-resolved, multi-chirality SWCNT spectral sensing can compress complex serum composition into a reproducible near-infrared biomarker signature for ALS.
Competing Interest Statement
The authors have declared no competing interest.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Samples were obtained from TargetALS. The biospecimens were collected according to 45 CFR Part 46, "Protection of Human Subjects" and de-identified according to 45 CFR 164.514 by TargetALS. IRB of University of Rhode Island waived ethical approval for this work
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors