Abstract
Nocturnal glucose regulation is modulated by autonomic and circadian mechanisms, yet their dynamic interplay in apparently healthy, free-living populations remains poorly studied. Here, we assessed 227,860 nights of concurrent sleep data from Ultrahuman AIR ring and M1 continuous glucose monitoring (CGM) system across 5849 adults globally to examine nocturnal cardio-metabolic coupling. We found that higher sleep consistency was inversely associated with glucose variability, and vice versa. Unsupervised clustering of metrics characterizing nightly sleep quality and demographic factors revealed phenotypes corresponding to better vs poorer metabolic management. Clustering on aggregated sleep scores differentiated users on metabolic metrics with larger effect sizes, rather than on base sleep metrics. A subgroup analysis of sleep sessions in the upper and lower quartiles of the sleep-metabolic spectrum, revealed an asymmetric coupling between metabolic and sleep factors in determining phenotype. Nights corresponding to poorer sleep-metabolic management displayed greater shape similarity between nightly heart rate (HR) and glucose curves, compared to sleep sessions with better sleep-metabolic management. These findings demonstrate that multi-sensor digital phenotyping can improve the profiling of sleep and metabolic alignment in largely healthy adults, with simple sleep/wake regularity emerging as a behaviorally tractable determinant of cardio-metabolic homeostasis.
Introduction
Sleep plays a central role in maintaining physiological homeostasis, coordinating both autonomic and metabolic processes. Through its influence on the autonomic nervous system, the sleeping brain regulates heart rate, pancreatic activity, and thereby glucose dynamics 1–6. Experimental and epidemiological evidence show that disruptions in these pathways, reflected in reduced heart rate variability or elevated resting heart rate, are linked to impaired insulin sensitivity 4,7, greater nocturnal glucose variability 2, and adverse metabolic outcomes over time 7–9. Together, these findings establish sleep as a key mediator between autonomic function and glucose metabolism, with broader implications for cardio-metabolic health (CMH) and non-communicable diseases (NCDs).
In conditions with glycemic impairment, sleep is often reported to be impaired 10–12. Treatments for Type 2 Diabetes (T2D), pre-diabetes etc. have largely prescribed lifestyle changes that focus on diet and exercise. The idea that sleep can also be leveraged as a therapeutic intervention has recently emerged and is a focus of active clinical investigation 13. Several population-level sleep studies show that sleep quality has declined in recent decades with at least 30% of the American population reporting less than six hours of nightly sleep 14,15 and similar patterns observed globally 16,17. These metrics include individuals who are largely disease-free and not receiving chronic care. Given the established adverse effects of insufficient sleep on CMH 16,18, it is important to clarify how day-to-day variation in sleep quality shapes these processes in free-living populations.
Night-to-night fluctuations in sleep duration, timing, and architecture may disrupt the stability of autonomic and metabolic regulation, yet this aspect has received relatively little attention compared to chronic sleep restriction. Much of the existing literature has instead focused on identifying individuals at heightened risk of diabetes 11,16,18, cardiovascular disease and NCD 18–20, or sleep apnea 21 based on average sleep heart rate, or glucose patterns separately. While valuable, this disease-oriented perspective offers limited insight into the subtle dynamics of sleep–metabolic regulation for preventative health. With the larger numbers of global citizens grappling with early stages of metabolic dysfunction or looking for optimising healthspan, this paucity of information becomes critical. Prior studies have often been constrained by small sample sizes 22 or reliance on tightly controlled clinical cohorts 23. Although wearable devices now enable longitudinal data collection in free-living populations, previous studies have combined wearables and continuous glucose monitoring (CGM) in prescribed dietary protocols or with specific sleep interventions 24. As such, there is a need for cataloging the natural variability in sleep and CMH in diverse populations during everyday behaviors.
Fluctuations in nocturnal heart rate may index underlying metabolic demands and autonomic regulation of glycemia via vagal–sympathetic balance, which modulates heart rate, hepatic glucose output, and pancreatic hormone secretion 25–27. Recent human studies further demonstrate that sleep microarchitecture and autonomic state transitions are temporally coupled with changes in interstitial glucose levels 22,23, underscoring the mechanistic plausibility of a dynamic link between cardiac and glycemic rhythms across the night. Despite these insights, empirical characterization of HR–glucose co-regulation in free-living populations remains extremely limited.
Prior work has focused primarily on heart rate variability (HRV) and glucose in small laboratory cohorts, reporting modest inverse associations 2 but constrained by sample size, controlled environments, and narrow physiological diversity. To our knowledge, no studies have systematically evaluated how heart rate and glucose respond together during naturalistic sleep in a large cohort of ostensibly healthy individuals. Such analyses could reveal early signatures of autonomic–metabolic instability and shed light on how subtle variations in sleep physiology contribute to emerging disparities in metabolic health.
In this study, we derived free living condition data from a cohort of 5849 smart Ultrahuman Ring AIR smart ring users who concurrently wore CGMs over 227,860 nights. This dataset provided an opportunity to examine how individuals in real-world settings regulate sleep and glucose dynamics. Specifically, we investigated, a) how metabolic factors and sleep patterns relate to changes in nocturnal heart rate and glucose variability, and b) whether nightly HR and glucose coupling is affected by distinct metabolic and sleep profiles.
Methods
Study Design, Participant Consent and Demographics
Study Design and Consent
Between January 2024 and June 2025, we identified 5849 concurrent users of the Ultrahuman Ring AIR and M1 CGM platform (using the Abbott Freestyle Libre 2, Pro and 3 models, Abbott 28) across ∼100 countries, contributing 227,860 nights of overlapping CGM and HR data. This was a real world, retrospective, observational survey based on data derived from Ultrahuman platform users and adhered to the Ultrahuman’s terms of use 29 and privacy policy 30, which allows for analysis of de-identified grouped data for scientific research. Thus, participants consented via the onboarding process on the Ultrahuman platform and continued product use. As the study was non-invasive and involved no dietary, sleep, or exercise interventions, with all reported data de-identified, explicit institutional ethics board approval was not required. A separate set of analysts extracted the data, ran computational approaches and then reviewed the results to ensure blinding.
For participant details for the data reported in Supplementary Figure S1 refer to Supplementary methods. For participant details of the comparison of nightly HR time-series data from Ultrahuman ring AIR with the SleepImage ring 31, referenced in the supplement, refer to Krishnan et al, 2025 32.
Filtering Criteria for Participant Demographics
To define a dataset that eliminated measurement errors and outliers, we applied filters as shown in Figure 1. Analyses were restricted to users aged 20–60 years with a body mass index (BMI) between 18 and 40 kg/m², and to those self-identifying as male or female. Nights were retained if total sleep duration was between 4 to 14 h to exclude fragmented or extremely lengthy sleep sessions of unclear origin.
Participant flow chart and selection criteria for all analyses. SS refers to Sleep Score, MS refers to Metabolic Score, HMS refers to High Metabolic Scorers, LMS to Low Metabolic Scorers, HSS to High Sleep Scorers, LSS to Low Metabolic Scorers, BHMS to Before Sleep high Metabolic scorers, and BLMS to Before Sleep low Metabolic scorers.
To exclude clinical populations, we only considered sessions where daily average glucose fell between 50-250 mg/dL and glucose variability was between 7-40% based on reference values for nominally healthy populations 33,34. Similarly, sessions where average sleep HR fell outside the 40-100 bpm range 35,36 and average sleep HRV was outside the 10-100 ms 37,38 range were also excluded.
To further restrict outliers, we removed sessions where the Ultrahuman score for sleep consistency was not defined, and where Ultrahuman’s derived metrics of Sleep score, and the night-time Metabolic score lay outside 1.5 times their IQR range (all Ultrahuman metrics defined below). We also simultaneously applied the IQR-filter for lowest sleep HR, retaining nights corresponding to lowest HR in the range of 40-82 bpm.
The Ultrahuman Sleep Consistency factor is a proprietary score (0-100) that serves as an input factor to the Sleep Score and quantifies consistency in sleep onset and offset times relative to a 14-session prior baseline. Higher scores refer to greater night-to-night consistency in sleep onset/offset times.
The Ultrahuman Sleep Score (SS) is a proprietary, aggregated score which ranges between 0-100 and includes contributors such as sleep duration (non-awake sleep time), sleep efficiency, number of awakenings, skin temperature, consistency in terms of timing of sleep onset and offset, fraction of non-light sleep, HR minimum time, average sleep heart rate and movements during sleep. Higher scores indicate better sleep. Based on the IQR rule with a factor of 1.5, only sessions with sleep scores between 47.5-100 were retained.
The Ultrahuman Metabolic score (MS) is a proprietary, aggregated daily score ranging between 0-100 with contributions from Glucose Variability (coefficient of variation; CV), mean glucose, and time in range (70-110 mg/dL) as described previously 39. Higher scores indicate better glucose metabolism. In this paper, we calculated MS over 24hrs (Fig. 2 and 3), in the time-window between sleep onset and offset (night MS, Figs. 4 & 5, supplementary tables S2 and S3), or in a 3hr window prior to sleep onset (supplementary figure S2, supplementary table S4). Night MS and 3-hour before sleep MS is calculated from the CGM data, which has a variable sampling rate of 1, 5, or 15 minutes, depending on CGM operation mode and model. In order to standardize the glucose time series, we interpolated the glucose data to a nominal sampling interval of 15 minutes using a time-weighted linear interpolation scheme where the data density is defined as the ratio of actual to expected data points within the time period, where expected data points were calculated as total time duration divided by the nominal sampling interval. All sessions with data density below 80% were excluded from the final dataset. Any gap in data greater than 32 minutes was treated as missing data. Based on the IQR rule with a factor of 1.5, only sessions with night MS scores between 38.5 - 100 were retained.
Coupling between central measures and variability of sleep and metabolic scores. a) Individual-level median sleep scores were binned in increments of 5 and plotted against the median of the individual-level interquartile range (IQR) of metabolic scores (blue dots). b) Medians of the individual-level IQR sleep score vs the mid-points of the binned median metabolic score (blue dots). Grey bars refer to the number of individuals in each bin, and the weighted least squares regressions are shown as dashed red lines in both plots.
k-means clustering to identify sleep-metabolic phenotypes. Scatter (t-SNE) plot of participants colour-coded as high scoring (blue) and low scoring (grey) from a k-means unsupervised clustering over (a) demographic, sleep score, and activity features and another (b) done over demographic, total sleep contributor, sleep consistency factor, and activity features, leaving out the aggregated sleep score variable. Silhouette score graphs for both clustering analysis in supplementary table S1. c, d) Metabolic and glucose metrics for the high and low scorer group from the clusters corresponding to a) and b) respectively. Tables show median and IQR values per CGM-derived metric for each cluster with p-values and associated effect size for difference between the clusters from a Mann-Whitney U test.
Sleep-metabolic characteristics of sleep sessions separated by one IQR of SS and night MS. Boxplots of (a) nocturnal average glucose, (b) nocturnal glucose variability, and (c) nocturnal time in range for sessions in HSS (green) and LSS (purple) groups. Boxplots of (c) average sleep HR, (d) average sleep HRV, and (e) lowest nocturnal HR for HMS (blue) and LMS (yellow) groups. In all boxplots, central horizontal lines represent medians, boxes denote IQR range, whiskers extend to 1.5 times the IQR range and circles represent outliers. Statistics on differences between groups in supplementary tables S2 and S3. Data on sleep metrics and demographic factors for BHMS and BLMS sessions in supplementary figure S2 and supplementary table S4.
HR-glucose coupling through correlation and DTW analysis. (a) Representative plot of amplitude-normalized and time-normalized glucose (blue) and HR (red) traces overlaid with DTW associations marked in light grey for each grid point. (b) Boxplots of Spearman correlation coefficients for each time lag (-15min, 0min, +15min) for HMS (blue) and LMS (yellow) groups. (c) Boxplots of Spearman correlation coefficients for each time lag (-15min, 0min, +15min) for HSS (green) and LSS (purple) groups. (d) Box plots of normalized DTW distances for HMS (blue) and LMS (yellow) groups (e) Box plots of normalized DTW distances for HSS (green) and LSS (purple) groups. In all boxplots, black lines represent medians, boxes represent IQR, and whiskers extend to 1.5 times IQR. Spearman correlations and DTW distances between nocturnal HR and glucose traces for the BHMS and BLMS groups reported in supplementary figure S3.
To ensure sufficient representation of each participant’s habitual health behaviors, only users with at least ten nights of valid data (ring and CGM) were included in the analysis. This threshold accommodated the most common CGM usage period of 14 days 40 and accounted for missing data due to real-world factors such as ring charging gaps or unsynced CGM sessions for users with only Near-Field-Communication (NFC) capable models.
After applying all filters, the final base dataset comprised 105,615 nights from 2,651 users, which was used for sleep–metabolic consistency and clustering analyses shown in Figures 2 & 3.
To produce a dataset to characterize high and low scoring sessions within the normal range (Fig. 4) and for the correlation and DTW analysis (Fig. 5), we computed quantiles of the sleep score and night metabolic score across all sessions. Sessions in the upper and lower quartiles of the SS and night MS distributions were labelled as High Sleep Scorers (HSS, SS >= 85), Low Sleep Scorers (LSS, SS <= 71), High Metabolic Scorers (HMS, night MS >= 94), and Low Metabolic Scorers (LMS, night MS <= 73) sessions, respectively. Additionally, for the analysis in supplementary figures S2 and S3, and supplementary table S4, we computed quantiles of the Metabolic score in a 3-hour period before sleep onset (before sleep) and picked sessions in the upper quartile to generate, BHMS (before sleep MS >= 90), and in the lower quartile to generate BLMS (before sleep MS <= 63) groups. Datasets were balanced by sampling down the more populous group to ensure an equal number of users between low and high groups, and by randomly sampling 14 sessions per user to ensure that users with greater number of sessions didn’t bias the analysis, ensuring that all selected sessions had greater than 80% HR data density.
Device and additional feature characteristics for Data Gathering
Ultrahuman Ring AIR
The Ultrahuman Ring AIR 41 aggregates HR, accelerometer, and temperature data every 5 minutes. These are used to derive sleep metrics like sleep onset and offset, sleep duration, HR metrics including average sleep HR, lowest sleep HR, and sleep HRV; and movement metrics like tosses and turns in sleep or daily step counts while awake.
Users input their age, gender, and BMI when they are onboarded on the Ultrahuman platform, and BMI can be user-updated at any later time point as well.
Additional Derived Ring AIR metrics
Apart from the Ultrahuman Sleep Score and Sleep Consistency factor, these are other proprietary algorithmic outputs that were used in our analyses.
The Ultrahuman Total Sleep contributor is a proprietary score (0-100) that serves as an input factor to the SS and is calculated as a linear transformation of sleep duration adjusted for subsequent daytime naps (if any).
The Ultrahuman Movement Score is a proprietary, dynamic score that ranges from 0-100 and is calculated as a composite of waking hours where sufficient activity is recorded, intensity of the activity, total steps and workout frequency. Higher movement scores reflect better movement habits while lower scores reflect longer periods of inactivity.
Comparisons of sleep metrics with medical grade devices are discussed in supplementary methods and supplementary Figure S1.
Metrics derived from parsing nocturnal CGM data using Glucose 360
Glucose360 is an open-source Python-based framework for event-based integration and analysis of CGM data and was made available by collaboration (prior to publication) 42 by the Snyder Laboratory, Stanford University School of Medicine. We utilized the Glucose360 to evaluate the CGM metrics of the nocturnal glucose dataset including mean glucose, glucose CV, and Time in Range (TIR). To ensure similar definitions to TIR used in metabolic score, the range 70–110 mg/dL was used for defining TIR 39. We modified the time window for computation of the above metrics from the standard 14-day window 40,43 to shorter windows appropriate to testing our hypotheses; namely a during sleep session (Figs 4 & 5, supplementary tables S2 and S3), and a period three hours prior to sleep onset (supplementary figures S2 and S3, supplementary table S4).
Unsupervised Clustering analysis
We segmented the filtered data of 2,651 users by performing unsupervised k-means clustering using MiniBatchKMeans implemented in scikit-learn v1.7.1 44. Features included age, gender, BMI, and the medians and IQRs of movement score, sleep score, total sleep contributor, and sleep consistency factor. Medians and IQRs for each feature were computed across sleep sessions per individual. All features were z-score normalized, and the number of features was reduced via principal component analysis (PCA) to retain ≥85% of the variance following established norms for real-world data 45,46. The number of clusters was chosen based on silhouette analysis. Visualization of clusters was done using a t-SNE plot 44 using the reduced PCA components with the cluster ids as the data group labels.
Pre-processing of HR and glucose time series
Nightly HR and glucose level data for the HMS, LMS, HSS, and LSS users were extracted to perform a correlation and dynamic time warping (DTW) analysis described below. Pre-processing prior to these analyses involved aligning overnight HR and glucose data between sleep onset and offset. Since the M1 CGM data was already interpolated onto a 15-min grid between sleep onset and offset, the HR data from the Ultrahuman ring AIR, recorded at 5-min intervals, was interpolated onto the glucose data grid while ensuring gaps of > 32 minutes in the HR data stream are treated as missing data. Multiple HR readings associated with a fixed grid point were mapped onto the grid using a time-weighted linear interpolation scheme. Nights with <80% coverage of both data streams on the common grid were excluded.
Statistics Approach and Packages Used
Central tendencies were reported as medians and variability as interquartile ranges unless otherwise specified due to the non-normal distribution of many metrics (e.g., bounded metrics like metabolic and sleep scores). Where appropriate, Mann-Whitney U tests were used to assess differences, with non-parametric cliff’s delta effect sizes reported. Outliers were defined as values lying beyond 1.5 times the interquartile range.
Weighted least squares regression for metabolic score and sleep score variability analysis
Weighted least squares (WLS) regression was used to assess associations between sleep and daily metabolic score variability on the base dataset of 2,651 users (Fig. 2). Per-user median and interquartile range (IQR) values for sleep and metabolic score were calculated and binned in 5-point intervals. The bin midpoints of the IQR sleep score were regressed against the median metabolic score values, and vice versa for IQR metabolic score versus median sleep score. Each bin was weighted by its user count using WLS with the aid of Python’s statsmodels package 47 to account for heteroscedasticity due to unequal sample sizes. Model fit was summarized using R² adjusted to sample size, and standard errors were computed under the default (non-robust) covariance structure.
Correlation analysis of HR and glucose
Associations between the pre-processed nightly HR and glucose levels for the HMS, LMS, HSS, and LSS groups were evaluated using Spearman’s rank correlation (SciPy v1.16.1; 48), at both zero lag and with a one-grid lag. Correlation coefficients were computed at a session-level across all groups. Statistical differences between groups were determined using the Mann-Whitney U test.
Dynamic Time Warping (DTW) analysis of HR and glucose
To quantify temporal alignment between HR and glucose time-series beyond monotonic association, we computed DTW distances between the pre-processed and z-scored HR and glucose traces. DTW was implemented with a Euclidean distance metric and Sakoe–Chiba window of two steps (±30 min). To account for differences in sleep duration, DTW distances were normalized by dividing by the number of grid points (DTW per step). Nightly DTW-per-step values were computed at a session-level and then compared between groups using the Mann–Whitney U test. Analyses were conducted in Python with custom functions built on the dtaidistance library 49.
Results
Userbase Profiles
The cohort comprised a larger fraction of men as compared to women (M/F ratio = 2.93), spanning a wide range of ages (20-60 y) and BMI (18-40). Participants self-reported no history of metabolic or cardiovascular disease or medication use. Table 1 provides the demographics information as well as sleep and glucose metrics. Median average sleep HR was within the normal range of 40-75 bpm 50,51. Since multiple factors affect HRV, establishing a normal range was challenging 52. However, the median HRV value of 36 ms was associated with most categorizations of healthy individuals 53. Sleep duration median fell just within the recommended range of 7-9 hours 54, though on the shorter side of the range, reflecting global trends 16,17. The median sleep score of 79 also reflected this trend of fair sleep quality but with scope for improvement. Median average glucose and median glucose CV values fell within the normal range found in other CGM studies on non-diabetic populations, i.e. 92-105 mg/dL, 13%-21% 34. Median TIR values were outside the 82%-91% range 34 however that was likely attributable to the tighter 70-110 mg/dL glucose range we used in this study compared to the standardized 70-180 mg/dL range 34. Taken together, the metrics indicated that a largely healthy cohort was included in this analysis.
Sleep consistency was linked to improved glycemic control and vice versa
We initially investigated the coupling between the daily metabolic score (MS) and sleep score (SS) variables as they provided broad insights into the interplay between sleep habits and daily glucose control. We found that higher median SS were negatively correlated with the interquartile range of MS (slope = –0.067, 95% CI [-0.111, -0.023], adjusted R² = 0.56, Figure 2a), and that higher median MS were negatively correlated with the interquartile range of SS (slope = –0.032, 95% CI [-0.050, -0.015], adjusted R² = 0.52, Figure 2b). Thus, not only was sleep consistency associated with better metabolic outcomes and vice versa, but because of the shallow slope in both graphs, relatively small improvements in consistency in one variable led to relatively large returns in terms of improved median scores of the other variable.
Determining sleep-metabolic phenotypes via unsupervised learning revealed consistency of total sleep duration and sleep start/end times to be the key driver of nocturnal metabolic control
We next investigated whether we could identify metabolic profiles using only sleep, demographic and activity features given that smart ring usage far exceeds CGM wear. To allow the data to dictate the phenotypic identity, we performed an unsupervised k-means clustering over 7 features; age, gender, BMI, median SS, IQR SS, median movement score, and IQR movement score (with medians and IQR computed across sleep sessions per individual) reduced to 5 principal components which captured 87.2% of total variance. This analysis revealed two groups based on maximizing silhouette score (supplementary table S1). A consistently higher scoring group on all metrics, comprising 57.4% of users, and a lower scoring group comprised of the remainder (Figure 3a, c). Median values of higher scoring users were median SS = 82, IQR SS = 9.5, median movement score = 65.5, IQR movement score = 16.5, gender ratio (M/F) = 1.94, median age = 42, BMI = 24.8.
While the lower scoring users were characterized by median SS = 74, IQR SS = 13.3, median movement score = 65.0, IQR movement score = 18.1, gender ratio (M/F) = 6.2, median age = 41, and median BMI = 29.3. These differences in the median and IQR of SS suggested that higher-scoring individuals displayed more typical and homogeneous profiles than lower-scoring ones with an altered BMI and gender distribution.
We used an importance score metric, defined as the ratio of the variance in the feature between clusters to total variance, to determine which set of features distinguished the clusters most strongly. The two groups were primarily distinguished by their median SS (importance score = 0.38), IQR SS (importance score = 0.29), median BMI (importance = 0.24), and gender (importance score = 0.23). Median and IQR of movement score and age had importance scores of 0.01 or less.
Given the primary importance of SS in discriminating between user phenotypes, we unpacked the aggregated score and investigated the effect of its primary contributors, namely total sleep contributor (which reflects sleep duration) and sleep consistency factor (which reflects consistency of sleep onset/offset times), in determining cluster identity (Figure 3b). These are also factors that individuals trying to impact their health can readily adjust in their lifestyle habits. For this analysis, we performed an unsupervised k-means clustering of the data on 9 features; age, gender, BMI, median total sleep contributor and IQR total sleep contributor, median sleep consistency factor and IQR sleep consistency factor, median movement score, and IQR movement score, where median and IQR were calculated across sessions for each user. Principal component analysis reduced the feature set to 6 features which captured 87.9% of the variance. The 2 clusters that emerged from this analysis (supplementary table S1) were also characterized by low and high scoring users (cluster proportion = 65.1% for high scoring users). High scoring users were characterized by median values of median sleep consistency factor = 97.5, IQR sleep consistency factor = 12.1, median total sleep contributor = 88.5, IQR total sleep contributor = 12.5, median movement score = 68, IQR movement score = 17.5, median BMI = 25.5, age = 42, gender ratio = 2.5. Low scoring users were characterized by median sleep consistency factor = 89.4, IQR sleep consistency factor = 24.9, median total sleep contributor = 84.5, IQR total sleep contributor = 18, median movement score = 60.5, IQR movement score = 16.9, median BMI = 28.8, age = 42, gender ratio = 4.2. The clusters were most uniquely identified by the IQR and median of sleep consistency factor (importance scores of 0.36 and 0.27, respectively), while IQR total sleep contributor and median BMI were next in importance (importance scores of 0.19 and 0.12, respectively). Gender, age, median and IQR of movement score, and median total sleep contributor had low to negligible discriminatory power (importance score of 0.10 and lower). Taken together, the consistency of sleep onset and offset as well as variability of sleep duration were key in distinguishing higher scoring users from lower scoring ones, consistent with the results shown in Fig. 2.
Interestingly, when we profiled the glycemic properties of these groups using CGM360 for both approaches, we found significant differences in MS, average glucose, CV, TIR although all glucose metrics were mostly in the normal range 39,55 (Figure 3c,d). Glucose metrics differences between groups showed small effect sizes for the clusters generated using the component sleep consistency contributor and total sleep contributor (Cliff’s delta of 0.11, 0.10, 0.14 for average glucose, GV, and TIR, respectively. Fig 3d) compared to clusters generated using the aggregated sleep score, where effect sizes were moderate (Cliff’s delta of 0.21, 0.16, 0.26 for average glucose, GV, and TIR, respectively. Fig 3c). Median metabolic scores for lower scoring groups, particularly those generated using aggregate sleep scores, approached the values of pre-diabetic populations 39. Taken together, the clustering analysis identified a primary role for sleep factors, specifically consistency in sleep metrics, in determining metabolic phenotype. Metabolic phenotypes were more robustly defined using the aggregated Ultrahuman sleep score versus its key contributing factors as well.
Sleep-metabolic phenotypes showed differing nightly Heart Rate and Glucose Coupling
After establishing directional associations between sleep and metabolic measures, we next examined how variability in one domain manifests when the other is at its extremes, while still drawing from a cohort of nominally healthy adults. Specifically, we sought to characterize the real-world limits of variation in sleep quality and nocturnal metabolic regulation, and to understand how deviations in one domain systematically influence the other. This approach was intended to provide interpretable, actionable insights into lifestyle-driven sleep–metabolic interactions. Absolute medians and IQRs are found in supplementary tables S2 and S3.
When sessions were stratified by sleep quality, high sleep score (HSS) and low sleep score (LSS) groups showed consistent differences in nocturnal glucose regulation. Sessions with higher sleep quality were characterized by lower overnight glucose levels, more stable glucose profiles, and a greater proportion of spent within the target glucose range. In contrast, poorer sleep quality was associated with higher and more variable nocturnal glucose and reduced time in range (Fig 4a, b,c, supplementary table S2). These glucose-related differences were larger than differences observed in other domains with expected median differences between HSS and LSS sessions of 6.4 mg/dL, 0.6, 13.9% for average nocturnal glucose, nocturnal CV, and nocturnal TIR, respectively. The two sleep-defined groups also differed in demographic characteristics, with lower age and BMI in the higher sleep quality group, and higher activity levels relative to the lower sleep quality group.
To enable symmetric comparisons, the dataset was similarly stratified using upper and lower quartiles of nocturnal metabolic quality, yielding high metabolic score (HMS) and low metabolic score (LMS) sessions. Here the emphasis was to see changes in sleep HR and HRV metrics. Higher metabolic quality nights were associated with lower average and minimum nocturnal HR and higher HRV (Fig 4c,d,e, supplementary table S3), indicating a more favourable autonomic profile with expected median differences between HMS and LMS sessions of 9 bpm, 7 ms, and 6 bpm for average sleep HR, average sleep HRV and lowest nocturnal HR, respectively. Sleep duration but not sleep consistency differed statistically between metabolic groups. However, the absolute median difference in sleep duration between the groups was small (10 min), suggesting that cardiovascular distinctions were not primarily driven by time asleep. As with sleep-based stratification, metabolic groups also differed in BMI, and activity levels, but not with age, with healthier metabolic profiles corresponding to lower BMI, and higher activity.
The effect sizes for differences between HR factors for the MS separated groups were larger than the effect sizes for differences between glucose metrics from the SS separated groups (supplementary tables S3 and S4) highlighting an asymmetric coupling between sleep and metabolism.
Given the relationship between glucose and HR observed above, we next tested whether those differences reflected in the coupling between nocturnal HR and glucose dynamics (Figure 5a). Spearman rank correlation coefficients between the glucose and HR traces of the metabolic score stratified sessions across all investigated lags, showed that the lower metabolic scoring group had significantly higher correlation coefficients of r = 0.26 ± 0.52, 0.29 ± 0.53, 0.29 ± 0.53 (median ± IQR); compared to the higher metabolic scoring group, r = 0.11 ± 0.42, 0.14 ±0.44, 0.13 ± 0.44 (median ± IQR), across time lags of -15 min, 0 min, +15 min (Fig. 5b). Coefficient values were significantly different between the groups with modest effect sizes of rrb = 0.20; rrb = 0.21; rrb = 0.23, (p < 0.001 for all, Mann-Whitney U test) for lags -15min, 0min, +15 min, respectively. Thus, nights with poorer metabolic management were associated with a relatively tighter synchronous coupling between nocturnal HR and glucose traces compared to nights with better metabolic management.
The HSS and LSS groups, separated on the basis of SS, did not show similar trends. Spearman rank correlation coefficients between glucose and HR traces for LSS were r = 0.18 ± 0.50, 0.21 ± 0.51, 0.20 ± 0.52 (median ± IQR); while HSS were, r = 0.16 ± 0.45, 0.18 ± 0.45, 0.17 ± 0.46 (median ± IQR) for lags -15min, 0min, +15 min, respectively. Effect sizes for differences in medians were rrb = 0.03, rrb = 0.04, rrb = 0.05 (p < 0.001, Mann-Whitney U test) for lags -15min, 0min, +15 min, respectively. Hence, there was no effective difference in correlation coefficients for glucose and HR traces between the sleep score segregated groups.
Since HR and glucose levels are subject to both intrinsic feedback loops and are affected independently by the autonomic nervous system, their coupling may be subject to variable time lags 2,25,56 that may not be captured by a simple correlation analysis. To account for this, we performed a Dynamic Time Warping (DTW) analysis between the z-score normalized HR and glucose traces. Since DTW associates points between traces by minimizing a distance measure which accounts for both timestamp and signal value, it complements the correlation analysis which associates points between traces purely on the basis of their timestamp (Fig 5a).
Path-length normalized DTW distances between HR and glucose traces for the HMS group was 0.17 ± 0.06 (median ± IQR) , and 0.16 ± 0.07 (median ± IQR) for LMS, with LMS significantly lower than the HMS group (p < 0.001) albeit with a small effect size of rrr= 0.10. For groups separated on SS, DTW distances were 0.16 ± 0.06 (median ± IQR) for HSS and 0.18 ± 0.07 (median ± IQR). DTW distances for HSS and LSS were significantly different from each other (p < 0.001) in the opposite direction, albeit with a small effect size of rrb= 0.16. However, in both cases, the low scoring group was marginally more variable, reflected in the greater IQR values (Fig 5 d,e).
Thus, while the HR and glucose traces did undergo greater simultaneous directional changes in sessions with poorer metabolic management compared to better metabolic management, sleep score-based session selection did not reflect this difference. When exploring HR-glucose coupling using a more lag-flexible association scheme via the DTW analysis, both SS and MS-based session selection criteria found marginally greater variability in lower control users, with only a small effective difference in their distributions. This is consistent with our previous results on the central role of consistency being a foundational feature segregating individuals on the sleep-metabolic spectrum.
Discussion
Leveraging a larger real-world database of concurrent sleep, HR, and CGM, we show that day-to-day sleep consistency is a central feature for glucose stability. Further, we found that simple, real-world features can partition individuals into reproducible sleep–metabolic profiles that are associated with distinctive patterns of nocturnal HR–glucose coupling. Practically, these associations reinforced the notion that sleep regularity is a low-cost, and behaviorally tractable intervention that can serve as a multiplier when improving metabolic stability in non-clinical populations, complementing diet and exercise guidance. Importantly, the fact that these relationships were observed in unselected, real-world behavior rather than in trial-induced routines enhances their ethological validity.
We interrogated the importance of consistent habits in a variety of ways in this project. Our first result on consistency of habits was garnered on the most relaxed inclusion criteria (Fig. 2). This analysis aimed to test whether simple, interpretable sleep-metabolic relationships could be identified in a large, real-world free-living dataset. The finding that consistency of habits in one domain (such as sleep) reflected in better control in another (glycemic control) is an easy takeaway that has to our knowledge only been demonstrated in small cohort studies within clinical populations 57–59. The steepness of the relationships also implies that using wearables that promote directionality by documenting habits would be uniquely suited to this kind of endeavour regardless of the algorithm used to map the changes in sleep and glycemic control.
We initially adopted an unsupervised clustering approach to understand the trends within the largely heterogenous and unlabelled dataset we had, based on recommended guidance from large scale longevity and health studies published previously 60–62. In the first k-means clustering we incorporated demographic, aggregated sleep metrics, and activity features. This segregated the population into two groups: high scoring cluster (median SS = 82; IQR SS = 9.5; BMI =24.8; M/F = 1.94) which can be thought of as those who either already had an optimized stereotypical daily lifestyle and were actively engaged in achieving it, and a lower-scoring cluster (median SS = 74; IQR SS = 13.3; BMI =29.3; M/F = 6.2) who perhaps due to various life pressures were unable to wield such control. The metabolic scores of the low scorers approached those of pre-diabetic populations while high scorers had metabolic scores of healthy or athletic populations based on earlier CGM-based characterization reports 39. The feature importance revealed median and IQR sleep score as the most discriminative variables. Movement score contributed little to between-cluster separation and perhaps merits further investigation based on known positive associations between long-term health and movement 60,61.
Our analysis comparing the effect of using aggregated sleep score versus primary drivers such as sleep duration and consistency was initially motivated by the question: whether sleep scoring complexity using multiple, weighted metrics provides an edge over simple metrics that are easier to understand for a lay person. In both cases, we could reproduce low- and high-scoring groups with similar demographic and glucose profiles, however the differences between high and low scorers were muted in the simple metrics compared to groups yielded by the aggregated sleep score clustering (Figure 3c,d). Interestingly, the aggregated sleep score was marginally better at identifying users on the cusp of pre-diabetes relative to just using sleep duration and consistency derived scores on their own. This is in-line with our expectation of small metabolic separations within the self-declared healthy populations and consistent with early-stage risk stratification rather than overt disease segregation. Additionally, this has implications for devising preventative health strategies that require future refinements. The largest effect size for differences in metabolic metrics was seen in the %TIR metric, likely due to the tight guidance range used by the Ultrahuman platform.
In the follow-up analysis, wherein we examined the metabolic profiles of sleep sessions separated by 1 IQR of sleep score, we found significant differences in glucose metrics, however with relatively small effect sizes (supplementary table S2). As a result of generating these groups based on session-level metrics, rather than at a user-level, we had 186 users out of 541 that appeared in both HSS and LSS groups. The overlap is likely owed to the fact that sleep quality is more variable from night-to-night as it is affected by a host of environmental factors that work independently and alongside innate physiological factors 63,64. On the other hand, glucose metabolism is more phenotypic 65,66 . This could potentially underlie the reduced strength of the differences seen in glucose metrics due to the significant fraction of users featuring in both HSS and LSS groups. Conversely, separating sessions by 1 IQR of night metabolic score, lead to differences in sleep HR metrics with larger effect sizes (supplementary table S3) likely due to the fact that the HMS and LMS sessions comprised of comparatively more distinct user profiles; only 56 users out of 431 appeared in both HMS and LMS groups.
While the HMS and LMS groups had large effective differences in HR metrics, they had similar sleep duration and equally consistent sleep onset/offset times (supplementary table S3). This stands in contrast to the primary role played by sleep duration and sleep consistency in identifying metabolic health in the user-based clustering analysis (Fig. 3). This highlights subtle characteristics of large cohort, real-world data, such as ours, wherein a user-based analysis across the entire dataset revealed significant directional improvements in metabolic health based on variation in sleep metrics such as increased sleep duration and sleep onset/wake time consistency. But these are likely washed out when analyzing nights at the far ends of the healthy metabolic spectrum; where demographic factors such as age or BMI emerge as stronger determinants of metabolic health (supplementary table S3) compared to lifestyle related factors such as sleep duration or sleep onset/wake time consistency. Thus, the set of primary factors that regulate metabolic health, and therefore guide its management, appear to be context dependent; lifestyle factors attain centrality for those closer to the healthy end of the metabolic health spectrum, such as athletes, who may be looking to optimize their health, whereas those approaching disease would more greatly benefit from interventions such as an altering BMI, that more directly affect physiology. Future longitudinal studies would be required to clarify how changes in sleep regularity and metabolic health interact over time. Building a refined predictive model leveraging these features would also be immensely beneficial in the context of wellness and preventative medicine. Taken together, these findings have strong implications on public health monitoring since wearables such as smart rings and watches, which are easier to use, can continuously monitor sleep, which can be highly variable, while CGMs can serve as a periodic in-depth assessment and to characterize metabolic profiles.
The time series analysis of HMS, LMS, HSS, and LSS users at the far ends of the healthy sleep-metabolic spectrum was an attempt to locate levers of autonomic tone via HR that coincide with glycemic changes in the night. We found that the LMS users exhibited stronger synchronous HR–glucose correlations across all time lags compared to HMS users (Figures 5b,c). However, HSS and LSS users, who were separated on SS, showed relatively similar correlations across all measured HR-glucose lags. Based on the greater number of overlap users in the sleep score segregated group, this would appear to indicate that correlation measures are more sensitive to phenotype than to environmental factors like variability in arousals, or stressors that simultaneously affect sleep quality, HR, and glucose. In contrast, the central finding from the DTW analysis, which aligned signals while allowing for variable lags, was that the difference between the groups segregated on either sleep or metabolic factors was small, however the lower scoring groups (LMS, LSS) had marginally more variable DTW scores compared to higher scoring groups (HMS, HSS). Better metabolic management in a 3 hour time window prior to sleep onset was associated with lower average sleep HR and lowest HR, as well as higher average sleep HRV (supplementary figure S2, supplementary table S4), similar to the trends seen for HMS and LMS sessions, suggesting a predictive role for pre-sleep metabolic factors in determining nocturnal autonomic tone. However, the high and low pre-sleep MS scores had similar nocturnal HR-glucose coupling (supplementary figure S3) measures indicating that HR-glucose coupling was not predicted by pre-sleep metabolic management. Further studies would be needed to examine the drivers of HR-glucose coupling such as meal times and other stressors prior to sleep onset. These results reflect a muted yet significant role for sleep and metabolic consistency even at the granular level. Given the paucity of studies that investigate this coupling, we believe that much additional work is required to parse out any tangible leverage from these signals, The results serve as an initial framework for understanding nocturnal sleep related synchrony at the organ level. Mechanistically, consistent sleep likely stabilizes autonomic tone, circadian phase, and feeding rhythms, thereby damping glycemic volatility through improved insulin sensitivity and predictable hepatic glucose output 67–70. Conversely, metabolically “stable” nights may reduce arousals and nocturnal sympathetic surges that fragment sleep.
This being an observational study of a self-selected cohort of wearable/CGM users in free-living conditions, does carry several limitations. Firstly, given the recruitment method, the Ultrahuman user base may not represent the general population wherein men were over-represented and residual confounding by unmeasured factors (chronotype, shift work, alcohol/caffeine, menstrual/menopausal status, undiagnosed sleep apnea, ad hoc and regular medications) is possible. Secondly, device-level constraints such as proprietary PPG-derived HR/HRV, CGM algorithms and computation of ‘sleep’ and ‘metabolic’ scores limit extrapolation with other wearable devices and platforms. However, given that these proprietary scores are designed to correlate with commonly measured sleep and glucose metrics and serve a directional trend detection goal, we expect broad agreement with the more commonly used component metrics of the proprietary scores. Effect sizes for some between-group differences were modest and most CGM metrics were in the normal range, consistent with early stratification rather than clinical separation. Correlation and DTW analyses remain descriptive and cannot establish directionality. In particular, as the DTW algorithm associates points with variable time lags, establishing physiological correlates to this measure remains challenging. We computed CGM metrics such as time in range over shorter windows—single nights or the 3 hours before bed—rather than the standard 14-day period 71. While this may increase within-person variability, shorter windows are better suited to capture dynamic, day-to-day coupling between sleep and glycemic control that we focus on in this paper. Because our analyses aggregate data across 10–14 nights and hundreds to thousands of participants, any added noise at the nightly level is unlikely to bias the overall findings. Our study benefits from the dual use of the ring and CGM in that we can objectively identify sleep onset and offset in order to characterize nocturnal glucose as opposed to only CGM-based studies that assume a fixed bedtime start and end, which may not be consistent with the natural variability of sleep 63,64.
In summary, we provide a first tandem analysis of smart ring and CGM use in a large, real-world and free-living data set of highly diverse composition to identify and reinforce relationships of glucose metabolism and sleep quality that work in a potential positive feedback loop. Users naturally segregate into phenotypes that leverage this bi-drectional association and are associated with distinct patterns of nocturnal HR-glucose coupling. This should be an area of active research to not only provide insights on a “generally” healthy population but also to offer avenues of new biomarker development that can develop into robust indications of lifestyle and well-being.
Author Contributions
A.B. (Aditi Bhattacharya) and H.-P.K. (Hans-Peter Kubis) conceived and designed the study. M.P. S. (Micheal P. Snyder) and T.W. (Tao Wang) provided expert advisory input, reviewed results, provided access to CGM 360 algorithm and advised on interpretation of results. D.G. (Dhruv Gandhi) performed the majority of the data analyses, was involved in interpretation of the results and contributed to manuscript drafting. N.D. (Nihav Dhawale) conducted additional analyses and led manuscript writing in collaboration with A.B. A.S. (Aditi Shanmugan) contributed to the design of the subgroup analyses. M.D. (Mathew Driller) collected validation data for the Ultrahuman Ring AIR sleep metrics. Anahi Reddy (A.R.) was involved in manuscript writing. All authors reviewed, edited, and approved the final manuscript.
Funding statement
The study was supported by Ultrahuman Healthcare Pvt. Ltd internal research funds.
Competing interests
At the time of data analysis and manuscript preparation. A.B., N.D., D.G., A.S., were employees of Ultrahuman Healthcare Pvt. Ltd; A.R. was an intern; H.-P.K. was and remains an advisor to Ultrahuman Healthcare Pvt. Ltd.; M.D. was retained on a contract for specific research analysis and collaborative activities; M.P. S. and T.W did not receive any material or fiduciary support from Ultrahuman for this project.
T.W. declares no other conflict of interest.
M.P.S. is a cofounder and scientific advisor of Xthera, Exposomics, Filtricine, Fodsel, iollo, InVu Health, January AI, Marble Therapeutics, Mirvie, Next Thought AI, Orange Street Ventures, Personalis, Protos Biologics, Qbio, RTHM, SensOmics. M.P.S is a scientific advisor of Abbratech, Applied Cognition, Enovone, Jupiter Therapeutics, M3 Helium, Mitrix, Neuvivo, Onza, Sigil Biosciences, Captify Inc, WndrHLTH, Yuvan Research, Ovul, Erudio and Lyten. MPS is an investor and scientific advisor of R42 and Swaza. MPS is an investor in Repair Biotechnologies. These positions are not related to this paper.
Data Availability
Study outcomes data can be made available upon reasonable request. The SS and MS platform codes and technical details are proprietary assets of Ultrahuman and will not be disclosed. A.B. stands guarantee of the veracity of the study data. For inquiries please contact Aditi Bhattacharya: aditi{at}ultrahuman.com.
Code Availability
Analysis code, apart from that containing proprietary information, can be available upon reasonable request. Please contact Nihav Dhawale: nihav{at}ultrahuman.com.
Ethics Declarations
This is a retrospective, observational study of users of the Ultrahuman ring AIR and M1 CGM, and adhered to the Ultrahuman’s terms of use 29 and privacy policy 30, which allows for analysis of de-identified grouped data for scientific research. Participants consented via the onboarding process on the Ultrahuman platform and continued product use. As the study was non-invasive and involved no dietary, sleep, or exercise interventions, with all reported data de-identified, explicit institutional ethics board approval was not required.
Acknowledgements
The authors would like to thank Aditya Patwari, Nishanth Kirshnan, and members of Ultrahuman backend and data analytics team for support in harnessing the user database. Special thanks to Neeraj Kumar, Adhit Shet and Bhuvan Srinivasan for infrastructural support. Authors also appreciate Dr. Sahil Chopra of Empower Sleep for helpful discussions around early ideation.