Abstract
Background Highly pathogenic avian influenza (HPAI) A(H5N1) clade 2.3.4.4b was first detected in birds in the United States in 2021 and an ongoing outbreak in dairy cattle began in early 2024. At least 70 U.S. cases have been identified in humans with exposure to infected cattle, poultry, and wild birds. No human-to-human transmission has been documented. However, as part of diagnostic preparedness, we evaluated the ability of currently available influenza tests to detect 2024 U.S. H5N1 strains.
Methods Contrived nasal swab samples were prepared using live or inactivated 2024 H5N1 and used to test twelve rapid antigen tests (lateral flow assays, or LFA), including 10 commercially-available influenza A LFAs and two H5-specific LFAs. Five point-of-care (POC) molecular assays were also tested. An inclusivity testing protocol was used, wherein a predetermined dilution series is used to evaluate each assay, enabling head-to-head comparison of assay performance.
Results All lateral flow assays and POC molecular tests were able to detect bovine 2024 H5N1 (genotype B3.13). Sensitivity for the POC molecular tests (heat-inactivated virus) ranged from 1.55 to 7.75 TCID50/swab. For 11/12 LFAs, including 10 commercial influenza A tests and an RUO H5 assay, sensitivity (live virus) ranged from 78-1550 TCID50/swab. Testing of four LFAs confirmed inclusivity for a genotype D1.1 strain.
Conclusions Available rapid antigen and point-of-care molecular influenza tests can detect 2024 U.S. H5N1 strains in contrived samples, with a wide range of analytical sensitivity. In the event of human-to-human transmission, clinical performance and optimal sample types would need to be established.
Summary Recent human infections with H5N1 influenza necessitate diagnostic preparedness. Reassuringly, commercially available rapid antigen and point-of-care molecular influenza tests detected the 2024 U.S. bovine H5N1 strain in contrived specimens. Clinical performance should be evaluated if human-to-human transmission is observed.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The research reported in this publication was supported by the National Institutes of Health contract number [75N92022D00015/75N92023F00001] and grant number [3U54EB027690-05S1] as part of the Rapid Acceleration of Diagnostics (RADx®) initiative.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
IRB of Emory University School of Medicine gave ethical approval for this work.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Footnotes
↵+ Co-first authors.
Data Availability
All data produced in the present study are available upon reasonable request to the authors