Abstract
Optical 3D surface scanning has emerged as a valuable modality for assessing spinal deformity in patients with scoliosis, avoiding radiation exposure. However, correlations remain moderate between deformation parameters obtained from radiographs and those estimated solely from the 3D back surface, referred to as the “back-shape-to-spine” approach. To improve the accuracy with which the back-shape-to-spine approach can estimate the internal spinal alignment (ISL) from 3D surface scanning, deeper understanding is required of the effect of scoliosis on the back shape. The PCdare software, which enables semi-automatic registration of 3D surface scans with the corresponding biplanar radiographs, has been used by students in a previous study to validate study protocols, generate references for estimated ISL, and evaluate correlations between the spinous process line (SPL) and ISL. This study explored the potential of the PCdare software to investigate the underlying relationship between the ISL and the 3D back shape, conducted a comparative study with 3 study protocols, and conducted an inter- and intrarater reliability (IIR) study with 6 clinicians and 10 students as raters to evaluate the applicability of PCdare when used by students. The comparative study involved 252 patients with idiopathic scoliosis from 3 studies that compared the back-shape-to-spine approach with radiography. The quality of study protocols and the relationship between internal spinal alignment and 3D back shape were both investigated by evaluating the posture alignment errors and correlations between Cobb angles. The inter- and intrarater reliability study involved 7 patients with idiopathic scoliosis and was conducted using PCdare and validated with PACS. The median Cobb angle difference (interquartile range: IQR) between students and clinicians (interclass) was 0.06° (1.5°). The ICC [confidence interval] between Cobb angles (interrater) was 0.94 [0.7,0.98]. The median absolute Cobb angle difference (IQR) between 3 repetitions (intrarater) were 4.2° (5.3°) or lower. The median Cobb angle difference (IQR) between PCdare and PACS was 1.5° (8.4°) for clinicians and 1.4° (6.9°) for students, whereas the corresponding correlation [confidence interval] was 0.94 [0.92,0.96] and 0.95 [0.93,0.96], respectively. The median RMSE (median SD) of posture alignment error ranged between 8.1 mm (5.2 mm) and 5 mm (3.5 mm), whereas the median PCC (IQR) between ISL and SPL ranged between 0.64 (0.58) and 0.99 (0.02). Students achieve outcomes comparable to clinicians when using PCdare, which underlines its reliability and ease of use. In addition, the application of PCdare to examine the quality of study protocols revealed the necessity of markers and posture alignment and delivered correlation coefficients for the relationship between internal spinal alignment and 3D back shape. These findings highlight the potential of the PCdare software to advance the non-ionizing assessment of spinal deformities and thus improve understanding of scoliosis.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
Yes
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Institutional Review Board Statement: The study at the Balgrist University Hospital was conducted in accordance with the Declaration of Helsinki and approved by the Cantonal Ethics Committee in Zurich (2022-01672, 22 November 2022).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
Data Availability Statement: The PCdare software code presented is openly available on GitHub at https://github.com/mkaisereth/PCdareSoftware including an illustrative data sample. The data for the study at the Balgrist University Hospital will be made publicly available in a separate data publication.