Abstract
Purpose To test whether the mean curvature of isophotes (MCI), a geometric image transformation, can be used to improve automatic detection on chest CT of Usual Interstitial Pneumonia (UIP), a determining radiological pattern in the diagnosis of Interstitial Lung Diseases (ILD).
Materials and methods This retrospective study included chest CT scans from 234 patients (123 female,111 male; mean age: 61.6 years; age range: 18-90 years) obtained at two independent institutions between 2007 and 2024.
Three different classification models were trained on the original CT images and separately on MCI-transformed CT images: (1) a previously published deep learning model for classifying fibrotic lung disease on chest CT, (2) a simplified version of the same, and (3) a non-deep-learning model based on the functional principal component analysis (FPCA) of density functions of voxel intensity.
All models were trained on data from the first institution and evaluated on data from the second institution with the recall-macro, precision-macro and F1-macro scores. Performance difference between classifier pairs was tested with the Stuart-Maxwell marginal homogeneity test.
Results For a fixed model architecture and training algorithm, MCI-transformed images yield comparable or better classification performance than the original CT images. The best performance improvement achieved with MCI compared to CT was: recall-macro 0.83 vs 0.57, precision-macro 0.81 vs 0.50, F1-macro 0.80 vs 0.49, p=4.2e-5.
Conclusion MCI may be a valuable addition to existing AI systems for screening for UIP on chest CT.
Summary statement Machine learning methods for identifying usual interstitial pneumonia on chest CT perform better when the input CT images are transformed via the mean curvature of isophotes (MCI), a geometric transformation method known from classical computer vision.
Key Points
Three machine learning models were trained on a dataset of 158 patients from one institution and tested on another dataset of 76 patients from an independent institution to discriminate for usual interstitial pneumonia (UIP) on chest CT in a 3-group classification task.
When keeping the network architecture and parameters fixed, changing the input image domain from the original CT to MCI-transformed images improved classification performance (Stuart-Maxwell test, p < .001)
MCI may be a valuable addition to existing machine learning systems for screening for UIP on chest CT, whether based on deep learning or on simpler shallow classifiers.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
PS acknowledges funding from NSERC Discovery Grant RGPIN-2018-05636. SB acknowledges funding from NSERC Discovery Grant RGPIN-2020-05133.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The McGill University Health Centre (MUHC) Research Ethics Committee (REB) gave ethical approval for this work. The Comité d'éthique è la recherche (CÉR) of the Centre Hospitalier de l'Université de Montréal (CHUM) gave ethical approval for this work.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
The images and data used in this study are hospital patient records, containing protected healthcare information (PHI). As such, we do not have the authority to share them or make them public.