Abstract
Background Recently, radiofrequency catheter ablation (RFCA) has become an important treatment strategy for atrial fibrillation (AF). During this procedure, achieving first-pass pulmonary vein (PV) isolation–PV isolation in which no residual conduction gap remains following initial circumferential lesion is created around the PV–has proven to lead better results in terms of AF recurrence. Although various risk factors for the creation of residual conduction gap have been proposed, the relationship between the transseptal puncture location on fossa ovalis and first-pass PV isolation success rate has not been clarified. Therefore, we investigate the relationship through this investigation.
Methods Overall, 102 consecutive patients who had undergone their first RFCA for AF were included. These patients were divided based on the transseptal puncture location (infero-anterior, infero-posterior, supero-anterior, and supero-posterior), which was confirmed by imaging of three-dimensional structure of the anatomical fossa ovalis creating intracardiac echocardiography. The relationship between transseptal puncture location and the first-pass PV isolation success rate was analyzed.
Results Among all 102 patients, number of transseptal puncture location were located in infero-anterior, infero-posterior, supero-anterior, and supero-posterior were 26, 61, 6, and 9 respectively. Among these, first-pass PV isolation success rate in the infero-posterior group exhibited the highest 79% (48/61 patients) compared to that in other locations [infero-anterior 61% (16/26 patients), supero-anterior 33% (2/6 patients), and supero-posterior 44% (4/9 patients); P=0.02]. Regarding ablation parameters, although the ablation index was not significantly different between each group (infero-anterior 401.6±7.6, infero-posterior 401.9±5.2, supero-anterior 397.5±4.7, and supero-posterior 398.6±5.3; P = 0.176). The P-vector, which represents insufficient catheter contact, was significantly observed lower frequency in the infero-posterior group (8.6%; P < 0.01) than in the other groups.
Conclusion The transseptal puncture location in PV isolation is an important factor to achieve first-pass PV isolation, and it might affect AF recurrence.
Non-standard Abbreviations and Acronyms AF, atrial fibrillation; AI, ablation index; FAM, fast anatomical map; PV, pulmonary vein; RFCA, radiofrequency catheter ablation
Clinical Perspective
What is Known?
Although transseptal puncture is an essential technique in atrial fibrillation ablation, the relationship between the transseptal puncture location on the fossa ovalis and first-pass pulmonary vein isolation success rate has not been fully evaluated so far.
What the Study Adds
Transseptal puncture at the infero-posterior region on the fossa ovalis was shown to result in a higher first-pass PV isolation proportion than that in other locations, owing to the better catheter contact situation.
When performing catheter ablation for atrial fibrillation, it should be kept in mind that the transseptal puncture location might affect atrial fibrillation recurrence.
Competing Interest Statement
Dr Tsujita has received honoraria from AMI Co., Ltd., Bayer Yakuhin, Ltd., Bristol-Myers K.K., EA Pharma Co.,Ltd., Mochida Pharmaceutical Co., Ltd., and scholarship fund from AMI Co., Ltd., Bayer Yakuhin, Ltd., Boehringer Ingelheim Japan, Chugai Pharmaceutical Co, Ltd., Daiichi Sankyo Co., Ltd., Edwards Lifesciences Corporation, Johnson & Johnson K.K., Ono Pharmaceutical Co., Ltd., Otsuka Pharmaceutical Co.,Ltd., Takeda Pharmaceutical Co., Ltd., and honoraria from Amgen K.K., Bayer Yakuhin, Ltd., Daiichi Sankyo Co., Ltd., Kowa Pharmaceutical Co. Ltd., Novartis Pharma K.K., Otsuka Pharmaceutical Co.,Ltd., Pfizer Japan Inc., and belongs to the endowed departments donated by Abbott Japan Co., Ltd., Boston Scientific Japan K.K., Fides-one, Inc., GM Medical Co., Ltd., ITI Co.,Ltd., Kaneka Medix Co., Ltd., Nipro Corporation, Terumo Co, Ltd., Abbott Medical Co., Ltd., Cardinal Health Japan, Fukuda Denshi Co., Ltd., Japan Lifeline Co.,Ltd., Medical Appliance Co., Ltd., Medtoronic Japan Co., Ltd.
Clinical Trial
This study is retrospective study. Therefore, no clinical trial ID was assigned.
Funding Statement
This investigation was supported by the Johnson & Johnson Medical Research Grant and Takeda Science Foundation.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study adhered to the Declaration of Helsinki principles and received approval from the Institutional Review Board and Ethics Committee of Kumamoto University (approval number 2772).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
The datasets used and analyzed during the current study available from the corresponding author on reasonable request.