Abstract
Purpose To assess the efficacy and safety of repeated low-level red-light (RLRL) therapy in controlling myopia progression among multi-ethnic school-aged children. This report focuses on 3-month interim analysis.
Design Multi-ethnic, parallel controlled randomized trial
Participants A total of 34 children aged 8-13 years with myopia of cycloplegic spherical equivalent (SE) of −0.50 to – 5.00 (inclusive) diopters (D), astigmatism of 2.50 D or less, anisometropia of 1.50 D or less, and monocular best-corrected visual acuity (BCVA) of 20/20 or better were enrolled.
Methods Participants were randomly assigned to the RLRL group (n = 16) or the single-vision spectacles (SVS) group (n = 18). RLRL therapy was administered twice daily on weekdays for 3-minute sessions, while the SVS group continued routine activities. Assessments were scheduled at baseline and follow-up visits at 1, 3, 6, and 12 months, with compliance monitoring and safety assessments throughout.
Main Outcome Measures The primary outcome and a key secondary outcome included axial length (AL) change and cycloplegic spherical equivalent (SE) change.
Results A total of 31 (91.2%) participated in the 3-month follow-up visit. The RLRL group demonstrated a significant shortening in AL (−0.07 ± 0.07 mm) compared to the SVS group (0.03 ± 0.05 mm, P<0.001). Similarly, SE progression was hyperopic shift in the RLRL group (0.26 ± 0.14 D) while the SVS group exhibited a myopic shift (−0.03 ± 0.38 D, P=0.009). No severe adverse events were reported.
Conclusions The 3-month interim analysis shows that the efficacy of RLRL therapy in controlling myopia progression among multi-ethnic children is comparable to, or even better than, that idenfied in Chinese patients in previous trials.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Trial
ACTRN12622000526774p
Funding Statement
This work was supported by Eyernising international.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The study protocol was approved by the Ethics Committee of The Royal Children's Hospital (Identifier, HREC 82296), and adhered to the tenets of the Declaration of Helsinki.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Footnotes
Financial Support: This work was supported by Eyernising international.
Competing Interests: No conflicting relationship exists for any author.
Data Availability
Data will be made available upon reasonable request. To request access, please contact the corresponding author (ndeen{at}aco.org.au).
Abbreviations and Acronyms
- RLRL=
- repeated low-level red-light
- SVS=
- single-vision spectacles
- SE=
- spherical equivalent
- D=
- diopters
- AL=
- axial length
- VA=
- visual acuit
- BCVA=
- best-corrected visual acuity
- UCVA=
- uncorrected visual acuity
- RCT=
- randomized Controlled Trial
- DSMC=
- data and safety monitoring committee
- ACD=
- anterior chamber depth
- CC=
- corneal curvature
- WTW=
- white-to-white
- OCT=
- optical coherence tomography
- AE=
- adverse event