Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct (2H) and indirect (1H) detection of deuterium labeled compounds at 7T and clinical 3T

View ORCID ProfileFabian Niess, View ORCID ProfileBernhard Strasser, View ORCID ProfileLukas Hingerl, View ORCID ProfileEva Niess, View ORCID ProfileStanislav Motyka, View ORCID ProfileGilbert Hangel, View ORCID ProfileMartin Krššák, View ORCID ProfileStephan Gruber, View ORCID ProfileBenjamin Spurny-Dworak, View ORCID ProfileSiegfried Trattnig, View ORCID ProfileThomas Scherer, View ORCID ProfileRupert Lanzenberger, View ORCID ProfileWolfgang Bogner
doi: https://doi.org/10.1101/2023.04.17.23288672
Fabian Niess
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Fabian Niess
  • For correspondence: fabian.niess@meduniwien.ac.at
Bernhard Strasser
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Bernhard Strasser
Lukas Hingerl
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Lukas Hingerl
Eva Niess
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
2Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Eva Niess
Stanislav Motyka
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
2Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Stanislav Motyka
Gilbert Hangel
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
3Department of Neurosurgery, Medical University of Vienna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Gilbert Hangel
Martin Krššák
4Department of Medicine III, Division of Endocrinology and Metabolism, Medical University of Vienna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Martin Krššák
Stephan Gruber
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
2Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Stephan Gruber
Benjamin Spurny-Dworak
5Department of Psychiatry and Psychotherapy, Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Benjamin Spurny-Dworak
Siegfried Trattnig
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
6Institute for Clinical Molecular MRI, Karl Landsteiner Society, 3100 St. Pölten, Austria
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Siegfried Trattnig
Thomas Scherer
4Department of Medicine III, Division of Endocrinology and Metabolism, Medical University of Vienna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Thomas Scherer
Rupert Lanzenberger
5Department of Psychiatry and Psychotherapy, Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Rupert Lanzenberger
Wolfgang Bogner
1High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna
2Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Wolfgang Bogner
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Introduction Deuterium metabolic imaging (DMI) and quantitative exchange label turnover (QELT) are novel MR spectroscopy techniques for non-invasive imaging of human brain glucose and neurotransmitter metabolism with high clinical potential. Following oral or intravenous administration of non-ionizing [6,6’-2H2]-glucose, its uptake and synthesis of downstream metabolites can be mapped via direct or indirect detection of deuterium resonances using 2H MRSI (DMI) and 1H MRSI (QELT), respectively.

The purpose of this study was to compare the dynamics of spatially resolved brain glucose metabolism, i.e., estimated concentration enrichment of deuterium labeled Glx (glutamate+glutamine) and Glc (glucose) acquired repeatedly in the same cohort of subjects using DMI at 7T and QELT at clinical 3T.

Methods Five volunteers (4m/1f) were scanned in repeated sessions for 60 min after overnight fasting and 0.8g/kg oral [6,6’-2H2]-glucose administration using time-resolved 3D 2H FID-MRSI with elliptical phase encoding at 7T and 3D 1H FID-MRSI with a non-Cartesian concentric ring trajectory readout at clinical 3T.

Results One hour after oral tracer administration regionally averaged deuterium labeled Glx4 concentrations and the dynamics were not significantly different over all participants between 7T 2H DMI and 3T 1H QELT data for GM (1.29±0.15 vs. 1.38±0.26 mM, p=0.65 & 21±3 vs. 26±3 µM/min, p=0.22) and WM (1.10±0.13 vs. 0.91±0.24 mM, p=0.34 & 19±2 vs. 17±3 µM/min, p=0.48). Also, the observed time constants of dynamic Glc6 data in GM (24±14 vs. 19±7 min, p=0.65) and WM (28±19 vs. 18±9 min, p=0.43) dominated regions showed no significant differences.

Between individual 2H and 1H data points a weak to moderate negative correlation was observed for Glx4 concentrations in GM (r=-0.52, p<0.001), and WM (r=-0.3, p<0.001) dominated regions, while a strong negative correlation was observed for Glc6 data GM (r=- 0.61, p<0.001) and WM (r=-0.70, p<0.001).

Conclusion This study demonstrates that indirect detection of deuterium labeled compounds using 1H QELT MRSI at widely available clinical 3T without additional hardware is able to reproduce absolute concentration estimates of downstream glucose metabolites and the dynamics of glucose uptake compared to 2H DMI data acquired at 7T. This suggests significant potential for widespread application in clinical settings especially in environments with limited access to ultra-high field scanners and dedicated RF hardware.

Competing Interest Statement

R. Lanzenberger received investigator-initiated research funding from Siemens Healthcare regarding clinical research using PET/MR. He is a shareholder of the start-up company BM Health GmbH since 2019.

Clinical Trial

DRKS00013218

Funding Statement

This work was supported by the National Institute of Health NIH R01EB031787 and the Austrian Science Fund: WEAVE I 6037 & KLI 1106 and Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK)

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

I confirm that the current study was approved by the ethic commission of the Medical University of Vienna and written informed consent was obtained from all participants.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Footnotes

  • Institutional address: High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Lazarettgasse 14, A-1090 Vienna, Austria

  • Funders: This work was supported by the National Institute of Health NIH R01EB031787 and the Austrian Science Fund: WEAVE I 6037 & KLI 1106 and Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK)

  • Declaration of interest: R. Lanzenberger received investigator-initiated research funding from Siemens Healthcare regarding clinical research using PET/MR. He is a shareholder of the start-up company BM Health GmbH since 2019.

Data Availability

Data generated by postprocessing methods (i.e., metabolic maps, LCModel basis sets, script files for data handling) are available online at: (https://github.com/MRSI-HFMR-Group-Vienna/DMIvsQELT.git). Raw data files are too large to be shared publicly and are available from the corresponding author on reasonable request for research purposes only. Due to data protection policy 3D high resolution images are only available upon reasonable request from the corresponding author if approved by the requesting researchers local ethics committee. Link: https://github.com/MRSI-HFMR-Group-Vienna/DMIvsQELT.git).

https://github.com/MRSI-HFMR-Group-Vienna/DMIvsQELT.git

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC 4.0 International license.
Back to top
PreviousNext
Posted April 17, 2023.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct (2H) and indirect (1H) detection of deuterium labeled compounds at 7T and clinical 3T
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct (2H) and indirect (1H) detection of deuterium labeled compounds at 7T and clinical 3T
Fabian Niess, Bernhard Strasser, Lukas Hingerl, Eva Niess, Stanislav Motyka, Gilbert Hangel, Martin Krššák, Stephan Gruber, Benjamin Spurny-Dworak, Siegfried Trattnig, Thomas Scherer, Rupert Lanzenberger, Wolfgang Bogner
medRxiv 2023.04.17.23288672; doi: https://doi.org/10.1101/2023.04.17.23288672
Reddit logo Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct (2H) and indirect (1H) detection of deuterium labeled compounds at 7T and clinical 3T
Fabian Niess, Bernhard Strasser, Lukas Hingerl, Eva Niess, Stanislav Motyka, Gilbert Hangel, Martin Krššák, Stephan Gruber, Benjamin Spurny-Dworak, Siegfried Trattnig, Thomas Scherer, Rupert Lanzenberger, Wolfgang Bogner
medRxiv 2023.04.17.23288672; doi: https://doi.org/10.1101/2023.04.17.23288672

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (269)
  • Allergy and Immunology (549)
  • Anesthesia (135)
  • Cardiovascular Medicine (1749)
  • Dentistry and Oral Medicine (238)
  • Dermatology (172)
  • Emergency Medicine (310)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (654)
  • Epidemiology (10785)
  • Forensic Medicine (8)
  • Gastroenterology (584)
  • Genetic and Genomic Medicine (2935)
  • Geriatric Medicine (286)
  • Health Economics (531)
  • Health Informatics (1919)
  • Health Policy (833)
  • Health Systems and Quality Improvement (743)
  • Hematology (290)
  • HIV/AIDS (627)
  • Infectious Diseases (except HIV/AIDS) (12501)
  • Intensive Care and Critical Care Medicine (685)
  • Medical Education (299)
  • Medical Ethics (86)
  • Nephrology (323)
  • Neurology (2786)
  • Nursing (150)
  • Nutrition (431)
  • Obstetrics and Gynecology (556)
  • Occupational and Environmental Health (597)
  • Oncology (1458)
  • Ophthalmology (441)
  • Orthopedics (172)
  • Otolaryngology (255)
  • Pain Medicine (190)
  • Palliative Medicine (56)
  • Pathology (380)
  • Pediatrics (865)
  • Pharmacology and Therapeutics (362)
  • Primary Care Research (334)
  • Psychiatry and Clinical Psychology (2633)
  • Public and Global Health (5342)
  • Radiology and Imaging (1004)
  • Rehabilitation Medicine and Physical Therapy (595)
  • Respiratory Medicine (724)
  • Rheumatology (329)
  • Sexual and Reproductive Health (289)
  • Sports Medicine (278)
  • Surgery (327)
  • Toxicology (47)
  • Transplantation (149)
  • Urology (125)