Assessing the effectiveness of portable HEPA air cleaners for reducing particulate matter exposure in King County, Washington homeless shelters during the COVID-19 pandemic: implications for community congregate settings

View ORCID ProfileChing-Hsuan Huang, Thu Bui, Daniel Hwang, Jeffry Shirai, Elena Austin, Martin Cohen, Timothy Gould, Timothy Larson, Igor Novosselov, Shirlee Tan, Edmund Seto
doi: https://doi.org/10.1101/2023.01.20.23284493
Ching-Hsuan Huang
aDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States 98195
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Ching-Hsuan Huang
  • For correspondence: hsuan328{at}uw.edu
Thu Bui
bPublic Health – Seattle and King County, Seattle, Washington, United States 98104
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Daniel Hwang
bPublic Health – Seattle and King County, Seattle, Washington, United States 98104
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jeffry Shirai
aDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States 98195
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elena Austin
aDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States 98195
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Cohen
aDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States 98195
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Timothy Gould
dDepartment of Civil and Environmental Engineering, College of Engineering, University of Washington, Seattle, Washington, United States 98195
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Timothy Larson
aDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States 98195
dDepartment of Civil and Environmental Engineering, College of Engineering, University of Washington, Seattle, Washington, United States 98195
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Igor Novosselov
cDepartment of Mechanical Engineering, College of Engineering, University of Washington, Seattle, Washington, United States 98195
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shirlee Tan
bPublic Health – Seattle and King County, Seattle, Washington, United States 98104
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Edmund Seto
aDepartment of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States 98195
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Over four thousand portable air cleaners (PACs) with high-efficiency particulate air (HEPA) filters were distributed by Public Health - Seattle & King County to homeless shelters during the COVID-19 pandemic. This study aimed to evaluate the real-world effectiveness of these HEPA PACs in reducing indoor particles and understand the factors that affect their use in homeless shelters. Four rooms across three homeless shelters with varying geographic locations and operating conditions were enrolled in this study. At each shelter, multiple PACs were deployed based on the room volume and PAC’s clean air delivery rate rating. The energy consumption of these PACs was measured using energy data loggers at 1-min intervals to allow tracking of their use and fan speed for three two-week sampling rounds, separated by single-week gaps, between February and April 2022. Total optical particle number concentration (OPNC) was measured at 2-min intervals at multiple indoor locations and an outdoor ambient location. The empirical indoor and outdoor total OPNC were compared for each site. Additionally, linear mixed-effects regression models (LMERs) were used to assess the relationship between PAC use time and indoor/outdoor total OPNC ratios (I/OOPNC). Based on the LMER models, one percent increase in the hourly, daily and total time PACs were used significantly reduced I/OOPNC by 0.34 [95% CI: 0.28, 0.40], 0.51 [95% CI: 0.20, 0.78], 2.52 [95% CI: 1.50, 3.28], respectively, indicating that keeping PACs on resulted in significantly lower I/OOPNC or relatively lower indoor total OPNC than outdoors. The survey suggested that keeping PACs on and running was the main challenge when operating them in shelters. These findings suggested that HEPA PACs were an effective short-term strategy to reduce indoor particle levels in community congregate living settings during non-wildfire seasons and the need for formulating practical guidance for using them in such an environment.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This project was supported by cooperative agreement EH20-2005 funded by the Centers for Disease Control and Prevention.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Human Subjects Division of University of Washington gave ethical approval for this work. Institutional Review Board of Washington State gave ethical approval for this work.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

Data not available due to participant consent.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC 4.0 International license.
Back to top
PreviousNext
Posted January 22, 2023.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Assessing the effectiveness of portable HEPA air cleaners for reducing particulate matter exposure in King County, Washington homeless shelters during the COVID-19 pandemic: implications for community congregate settings
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Assessing the effectiveness of portable HEPA air cleaners for reducing particulate matter exposure in King County, Washington homeless shelters during the COVID-19 pandemic: implications for community congregate settings
Ching-Hsuan Huang, Thu Bui, Daniel Hwang, Jeffry Shirai, Elena Austin, Martin Cohen, Timothy Gould, Timothy Larson, Igor Novosselov, Shirlee Tan, Edmund Seto
medRxiv 2023.01.20.23284493; doi: https://doi.org/10.1101/2023.01.20.23284493
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Assessing the effectiveness of portable HEPA air cleaners for reducing particulate matter exposure in King County, Washington homeless shelters during the COVID-19 pandemic: implications for community congregate settings
Ching-Hsuan Huang, Thu Bui, Daniel Hwang, Jeffry Shirai, Elena Austin, Martin Cohen, Timothy Gould, Timothy Larson, Igor Novosselov, Shirlee Tan, Edmund Seto
medRxiv 2023.01.20.23284493; doi: https://doi.org/10.1101/2023.01.20.23284493

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Public and Global Health
Subject Areas
All Articles
  • Addiction Medicine (430)
  • Allergy and Immunology (756)
  • Anesthesia (221)
  • Cardiovascular Medicine (3294)
  • Dentistry and Oral Medicine (364)
  • Dermatology (279)
  • Emergency Medicine (479)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (1171)
  • Epidemiology (13376)
  • Forensic Medicine (19)
  • Gastroenterology (899)
  • Genetic and Genomic Medicine (5153)
  • Geriatric Medicine (482)
  • Health Economics (783)
  • Health Informatics (3268)
  • Health Policy (1140)
  • Health Systems and Quality Improvement (1190)
  • Hematology (431)
  • HIV/AIDS (1017)
  • Infectious Diseases (except HIV/AIDS) (14627)
  • Intensive Care and Critical Care Medicine (913)
  • Medical Education (477)
  • Medical Ethics (127)
  • Nephrology (523)
  • Neurology (4925)
  • Nursing (262)
  • Nutrition (730)
  • Obstetrics and Gynecology (883)
  • Occupational and Environmental Health (795)
  • Oncology (2524)
  • Ophthalmology (724)
  • Orthopedics (281)
  • Otolaryngology (347)
  • Pain Medicine (323)
  • Palliative Medicine (90)
  • Pathology (543)
  • Pediatrics (1302)
  • Pharmacology and Therapeutics (550)
  • Primary Care Research (557)
  • Psychiatry and Clinical Psychology (4212)
  • Public and Global Health (7504)
  • Radiology and Imaging (1705)
  • Rehabilitation Medicine and Physical Therapy (1013)
  • Respiratory Medicine (980)
  • Rheumatology (480)
  • Sexual and Reproductive Health (497)
  • Sports Medicine (424)
  • Surgery (548)
  • Toxicology (72)
  • Transplantation (236)
  • Urology (205)