Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Estimation of free water-corrected microscopic fractional anisotropy

View ORCID ProfileNico J. J. Arezza, Mohammad Omer, View ORCID ProfileCorey A. Baron
doi: https://doi.org/10.1101/2022.10.27.22281560
Nico J. J. Arezza
1Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
2Centre for Functional and Metabolic Mapping (CFMM), Robarts Research Institute, Western University, London, Ontario, Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Nico J. J. Arezza
  • For correspondence: narezza@uwo.ca
Mohammad Omer
1Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Corey A. Baron
1Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
2Centre for Functional and Metabolic Mapping (CFMM), Robarts Research Institute, Western University, London, Ontario, Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Corey A. Baron
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Water diffusion anisotropy MRI is sensitive to microstructural changes in the brain that are hallmarks of various neurological conditions. However, conventional metrics like fractional anisotropy are confounded by neuron fiber orientation dispersion, and the relatively low resolution of diffusion-weighted MRI gives rise to significant free water partial volume effects in many brain regions. Microscopic fractional anisotropy is a recent metric that can report water diffusion anisotropy independent of neuron fiber orientation dispersion but is still susceptible to free water contamination. In this paper, we present a free water elimination (FWE) technique to estimate microscopic fractional anisotropy and other related diffusion indices by implementing a model in which the MRI signal within a voxel is assumed to come from two distinct sources: a tissue compartment and a free water compartment. A two-part algorithm is proposed to rapidly fit a set of diffusion-weighted MRI volumes containing both linear- and spherical-tensor encoding acquisitions to the model. Simulations and in vivo acquisitions with four healthy volunteers indicated that the FWE method may be a feasible technique for measuring microscopic fractional anisotropy and other indices with greater specificity to neural tissue characteristics than conventional methods.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This work was supported by the Natural Sciences and Engineering Research Council of Canada (NSERC) under Grant Number RGPIN-2018-05448, Canada Research Chairs (950-231993), Canada First Research Excellence Fund to BrainsCAN, and the NSERC Postgraduate Doctoral Scholarship (PGS-D) program.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The Institutional Review Board at Western University gave ethical approval for this work.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • Conflict of Interest The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Data Availability

All data produced are available online at https://osf.io/etkgx/

https://osf.io/etkgx/

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted November 01, 2022.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Estimation of free water-corrected microscopic fractional anisotropy
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Estimation of free water-corrected microscopic fractional anisotropy
Nico J. J. Arezza, Mohammad Omer, Corey A. Baron
medRxiv 2022.10.27.22281560; doi: https://doi.org/10.1101/2022.10.27.22281560
Digg logo Reddit logo Twitter logo Facebook logo Google logo LinkedIn logo Mendeley logo
Citation Tools
Estimation of free water-corrected microscopic fractional anisotropy
Nico J. J. Arezza, Mohammad Omer, Corey A. Baron
medRxiv 2022.10.27.22281560; doi: https://doi.org/10.1101/2022.10.27.22281560

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Neurology
Subject Areas
All Articles
  • Addiction Medicine (215)
  • Allergy and Immunology (495)
  • Anesthesia (106)
  • Cardiovascular Medicine (1094)
  • Dentistry and Oral Medicine (195)
  • Dermatology (141)
  • Emergency Medicine (274)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (500)
  • Epidemiology (9760)
  • Forensic Medicine (5)
  • Gastroenterology (480)
  • Genetic and Genomic Medicine (2304)
  • Geriatric Medicine (222)
  • Health Economics (462)
  • Health Informatics (1554)
  • Health Policy (734)
  • Health Systems and Quality Improvement (602)
  • Hematology (236)
  • HIV/AIDS (501)
  • Infectious Diseases (except HIV/AIDS) (11636)
  • Intensive Care and Critical Care Medicine (616)
  • Medical Education (236)
  • Medical Ethics (67)
  • Nephrology (257)
  • Neurology (2140)
  • Nursing (134)
  • Nutrition (336)
  • Obstetrics and Gynecology (426)
  • Occupational and Environmental Health (517)
  • Oncology (1173)
  • Ophthalmology (363)
  • Orthopedics (128)
  • Otolaryngology (220)
  • Pain Medicine (145)
  • Palliative Medicine (50)
  • Pathology (309)
  • Pediatrics (694)
  • Pharmacology and Therapeutics (298)
  • Primary Care Research (266)
  • Psychiatry and Clinical Psychology (2173)
  • Public and Global Health (4649)
  • Radiology and Imaging (775)
  • Rehabilitation Medicine and Physical Therapy (456)
  • Respiratory Medicine (623)
  • Rheumatology (274)
  • Sexual and Reproductive Health (225)
  • Sports Medicine (210)
  • Surgery (250)
  • Toxicology (43)
  • Transplantation (120)
  • Urology (94)