Abstract
Computed tomography (CT) is an extensively used imaging modality capable of generating detailed images of a patient’s internal anatomy for diagnostic and interventional procedures. High-resolution volumes are created by measuring and combining information along many radiographic projection angles. In current medical practice, single and dual-view two-dimensional (2D) topograms are utilized for planning the proceeding diagnostic scans and for selecting favorable acquisition parameters, either manually or automatically, as well as for dose modulation calculations. In this study, we develop modified 2D to three-dimensional (3D) encoder-decoder neural network architectures to generate CT-like volumes from single and dual-view topograms. We validate the developed neural networks on synthesized topograms from publicly available thoracic CT datasets. Finally, we assess the viability of the proposed transformational encoder-decoder architecture on both common image similarity metrics and quantitative clinical use case metrics, a first for 2D-to-3D CT reconstruction research. According to our findings, both single-input and dual-input neural networks are able to provide accurate volumetric anatomical estimates. The proposed technology will allow for improved (i) planning of diagnostic CT acquisitions, (ii) input for various dose modulation techniques, and (iii) recommendations for acquisition parameters and/or automatic parameter selection. It may also provide for an accurate attenuation correction map for positron emission tomography (PET) with only a small fraction of the radiation dose utilized.
Competing Interest Statement
We acknowledge support through the National Institutes of Health (R01EB030494) and Philips Healthcare.
Funding Statement
We acknowledge support through the National Institutes of Health (R01EB030494) and Philips Healthcare.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Only existing public datasets were used
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors