Abstract
Objective Blood pressure (BP) is an important physiological index reflecting cardiovascular function. Continuous blood pressure monitoring helps to reduce the prevalence and mortality of cardiovascular diseases. In this study, we aim to estimate systolic blood pressure (SBP) and diastolic blood pressure (DBP) values continuously based on fingertip photoplethysmogram (PPG) waveforms using deep neural network models.
Methods Two models were proposed and both models consisted of three stages. The only difference between them was the method of extracting features from PPG signals in the first stage. Model 1 adopted Bidirectional Long Short-Term Memory (BiLSTM), while the other used convolutional neural network. Then, the residual connection was applied to multiple stacked LSTM layers in the second stage, following by the third stage with two fully connected layers.
Results Our proposed models outperformed other methods based on similar dataset or framework, while in our proposed models, the model 2 was superior to model 1. It satisfied the standard of Association for the Advancement of the Medical Instrumentation (AAMI) and obtained grade A for SBP and DBP estimation according to the British Hypertension Society (BHS) standard. The mean error (ME) and standard deviation (STD) for SBP and DBP estimations were 0.21 ± 6.40 mmHg and 0.19 ±4.71 mmHg, respectively.
Conclusion Our proposed models could extract important features of fingertip PPG waveforms automatically and realize cuff-less continuous BP monitoring, which can be helpful in the identification and early treatment of abnormal blood pressure, thus may reduce the occurrence of cardiovascular malignant events.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study did not receive any funding
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
https://www.kaggle.com/mkachuee/BloodPressureDataset
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes