First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging

View ORCID ProfileLeening P. Liu, View ORCID ProfileNadav Shapira, Pooyan Sahbaee, View ORCID ProfileMitchell Schnall, View ORCID ProfileHarold I. Litt, View ORCID ProfilePeter B. Noël
doi: https://doi.org/10.1101/2021.11.17.21266432
Leening P. Liu
1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
2Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Leening P. Liu
  • For correspondence: leening@seas.upenn.edu pbnoel@upenn.edu
Nadav Shapira
1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Nadav Shapira
Pooyan Sahbaee
3Siemens Medical Solutions, Malvern, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mitchell Schnall
1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Mitchell Schnall
Harold I. Litt
1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Harold I. Litt
Peter B. Noël
1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Peter B. Noël
  • For correspondence: leening@seas.upenn.edu pbnoel@upenn.edu
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Objective Evaluation of quantification capabilities at ultra-low radiation dose levels of a first-generation dual-source Photon-Counting Computed Tomography (PCCT) compared to a dual-source dual-energy CT (DECT) scanner.

Methods A multi-energy CT phantom was imaged with and without extension ring on both scanners over a range of radiation dose levels (CTDIvol 0.4 - 15.0 mGy). Scans were performed in different modes of acquisition for PCCT with 120 kVp and DECT with 70/Sn150 kVp and 100/Sn150 kVp. Various tissue inserts were used to characterize the precision and repeatability of Hounsfield Units (HUs) on virtual mono-energetic images between 40 and 190 keV. Image noise was additionally investigated at ultra-low radiation dose to illustrate PCCT’s ability to remove electronic background noise.

Results Our results demonstrate high precision of HU measurements for a wide range of inserts and radiation exposure levels with PCCT. We report high performance for both scanners across a wide range of radiation exposure levels with PCCT outperforming at low exposures compared to DECT. PCCT scans at lowest radiation exposures illustrate significant reduction in electronic background noise, with a mean percent reduction of 74% (p-value ∼10−8) compared to the 70/Sn150 kVp and 60% (p-value ∼10−6) compared to the 100/Sn150 kVp.

Conclusions This paper reports first experiences with a clinical dual-source PCCT scanner with Quantum technology. PCCT provides reliable HUs without disruption from electronic background noise for a wide range of dose values. Diagnostic benefits are not only for quantification at ultra-low-dose but also for imaging of obese patients.

Key Points

  • PCCT scanners with Quantum technology provide precise and reliable quantitative Hounsfield Units at ultra-low-dose levels.

  • Influence of electronic background noise can be removed at ultra-low dose acquisitions with PCCT.

  • Both spectral platforms have high performance along a wide range of radiation exposure levels with PCCT outperforming at low radiation exposures.

Competing Interest Statement

Harold I. Litt, Peter B. Noël, and Mitch Schnall have a research agreement with Siemens Healthineers. Pooyan Sahbaee is an employee of Siemens Healthineers.

Funding Statement

This study was funded by the National Institutes of Health (R01EB030494).

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

All data produced in the present study are available upon reasonable request to the authors.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted November 21, 2021.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging
Leening P. Liu, Nadav Shapira, Pooyan Sahbaee, Mitchell Schnall, Harold I. Litt, Peter B. Noël
medRxiv 2021.11.17.21266432; doi: https://doi.org/10.1101/2021.11.17.21266432
Digg logo Reddit logo Twitter logo Facebook logo Google logo LinkedIn logo Mendeley logo
Citation Tools
First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging
Leening P. Liu, Nadav Shapira, Pooyan Sahbaee, Mitchell Schnall, Harold I. Litt, Peter B. Noël
medRxiv 2021.11.17.21266432; doi: https://doi.org/10.1101/2021.11.17.21266432

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (216)
  • Allergy and Immunology (495)
  • Anesthesia (106)
  • Cardiovascular Medicine (1099)
  • Dentistry and Oral Medicine (196)
  • Dermatology (141)
  • Emergency Medicine (274)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (502)
  • Epidemiology (9781)
  • Forensic Medicine (5)
  • Gastroenterology (481)
  • Genetic and Genomic Medicine (2317)
  • Geriatric Medicine (223)
  • Health Economics (462)
  • Health Informatics (1563)
  • Health Policy (737)
  • Health Systems and Quality Improvement (606)
  • Hematology (238)
  • HIV/AIDS (506)
  • Infectious Diseases (except HIV/AIDS) (11655)
  • Intensive Care and Critical Care Medicine (617)
  • Medical Education (239)
  • Medical Ethics (67)
  • Nephrology (258)
  • Neurology (2146)
  • Nursing (134)
  • Nutrition (338)
  • Obstetrics and Gynecology (427)
  • Occupational and Environmental Health (518)
  • Oncology (1183)
  • Ophthalmology (365)
  • Orthopedics (128)
  • Otolaryngology (220)
  • Pain Medicine (147)
  • Palliative Medicine (50)
  • Pathology (312)
  • Pediatrics (698)
  • Pharmacology and Therapeutics (302)
  • Primary Care Research (267)
  • Psychiatry and Clinical Psychology (2187)
  • Public and Global Health (4672)
  • Radiology and Imaging (781)
  • Rehabilitation Medicine and Physical Therapy (457)
  • Respiratory Medicine (624)
  • Rheumatology (274)
  • Sexual and Reproductive Health (226)
  • Sports Medicine (210)
  • Surgery (252)
  • Toxicology (43)
  • Transplantation (120)
  • Urology (94)