Abstract
Collecting, processing, and storing blood samples for future analysis of biomarkers can be challenging when performed in resource limited environments. The preparation of dried blood spots (DBS) from heel or finger stick collection of whole blood is a widely used and established method. DBS pose less risk of infection from blood borne pathogens, do not require immediate specimen processing and tolerate a wider range of storage temperatures, and are easier to ship. As such, DBS are commonly used in large-scale surveys to assess infectious disease status and/or micronutrient status in vulnerable populations. Recently, we reported that DBS can be used with a multiplexed immunoassay, the Q-plex™ Human Micronutrient 7-plex Array (MN 7-plex). This tool can simultaneously quantify seven protein biomarkers related to micronutrient deficiencies (iodine, iron and vitamin A), inflammation and malarial antigenemia using plasma or serum. Serum ferritin, a key iron biomarker, cannot be measured from DBS due to red blood cell (RBC) ferritin confounding the results. In this study, we demonstrate the performance of a simple and rapid blood fractionation tool that passively separates serum from cellular components via diffusion through a membrane into a plasma collection disc (PCD) to produce plasma spots. We evaluated the concordance of MN 7-plex analyte concentrations from matched panels of eighty-eight samples of PCD, DBS, and wet plasma prepared from anticoagulated venous whole blood. The results show high correlation between eluates from PCD and DBS and wet plasma for each analyte. Serum ferritin measures from the PCD eluates were highly correlated to wet plasma samples. This suggests that surveillance for iron deficiency may be improved over the current methods restricted to only measuring sTfR in DBS as when used in combination with the MN 7-plex, all seven biomarkers can be simultaneously measured using PCDs.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
OPPOPP1154343 and OPP1135483. The Bill & Melinda Gates Foundation. P2C HD042828; Eunice Kennedy Shriver National Institute of Child Health and Human Development
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The WIRB protocol number for the collection of 80 blood samples was 20161665 and all specimens were obtained only after signed consent by each participant. The PATH Office of Research Affairs deemed the use of these samples to be non-human subjects research."
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced are available online at once the manuscript has been approved for publication.