Abstract
During the COVID-19 public health emergency, many actions have been undertaken to help ensure that patients and health care providers had timely and continued access to high-quality medical devices to respond effectively. The development and validation of new testing supplies and equipment, including collection swab, help expand the availability and capability for various diagnostic, therapeutic, and protective medical devices in high demand during the COVID-19 emergency. Here, we report the validation of a new injection-molded anterior nasal swab, ClearTip™, that was experimentally validated in a laboratory setting as well as in independent clinical studies in comparison to gold standard flocked swabs. We have also developed an in vitro anterior nasal tissue model, that offers an efficient and clinically relevant validation tool to replicate with high fidelity the clinical swabbing workflow, while being accessible, safe, reproducible, time and cost effective. ClearTip™ displayed a greater efficiency of release of inactivated virus in the benchtop model, confirmed by greater ability to report positive samples in a clinical study in comparison to flocked swabs. We also quantified in multi-center pre-clinical and clinical studies the detection of biological materials, as proxy for viral material, that showed a statistically significant difference in one study and a slight reduction in performance in comparison to flocked swabs. Taken together these results underscore the compelling benefits of non-absorbent injected molded anterior nasal swab for COVID-19 detection, comparable to standard flocked swabs. Injection-molded swabs, as ClearTip™, could have the potential to support future swab shortage, due to its manufacturing advantages, while offering benefits in comparison to highly absorbent swabs in terms comfort, limited volume collection, and potential multiple usage.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study was funded by the NIH RADx-Tech program under 3U54HL143541-02S1, 3U54HL143541-02S2 and U54EB007958-12S1. The views expressed in this manuscript are those of the authors and do not necessarily represent the views of the National Institute of Biomedical Imaging and Bioengineering; the National Heart, Lung, and Blood Institute; the National Institutes of Health, or the U.S. Department of Health and Human Services. Salary support to YCM and JH from U54EB007958 (Center POC Technologies Research for Sexually Transmitted Diseases).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This data presented in this study were reviewed and approved by the institutional review board of Washington University School of Medicine (protocol number 7453) and University of Massachusetts Lowell (protocol number 20-149-BUC-FUL).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors