Abstract
Purpose In 1H MRS-based thermometry of brain, averaging temperatures measured from more than one reference peak offers several advantages including improving the reproducibility, i.e., precision, of the measurement. This paper proposes theoretically and empirically optimal weighting factors to improve the weighted average of temperatures measured from three references.
Methods We first proposed concepts of equivalent noise and equivalent signal-to-noise ratio in terms of frequency measurement and a concept of relative frequency that allows the combination of different peaks in a spectrum for improving the precision of frequency measurement. Based on these, we then derived a theoretically optimal weighting factor and proposed an empirical weighting factor, both involving equivalent noise levels, for a weighted average of temperatures measured from three references, i.e., the singlets of NAA, Cr, and Ch, in 1H MR spectrum. We assessed these two weighting factors by comparing their errors in measurement of temperatures with the errors of temperatures measured from individual references; we also compared these two new weighting factors with two previously proposed weighting factors. These errors were defined as the standard deviations (SDs) in repeated measurements or in Monte Carlo studies.
Results Both the proposed theoretical and empirical weighting factors outperformed the two previously proposed weighting factors as well as the three individual references in all phantom and in vivo experiments. In phantom experiments with 4 Hz or 10 Hz line broadening, the theoretical weighting factor outperformed the empirical one, but the latter was superior in all other repeated and Monte Carlo tests performed on phantom and in vivo data.
Conclusion The proposed weighting factors are superior to the two previously proposed weighting factors and can improve the reproducibility of temperature measurement using the 1H MRS-based thermometry.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
No external funding was received.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
IRB of the New York State Psychiatric Institute
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data is available subject to the regulations of the New York State Psychiatric Institute and Columbia University.No
Abbreviations and syllables
- A
- amplitude
- Ch
- choline
- Cr
- creatine
- CRLB
- Cramer-Rao Lower Bound
- MC
- Monte Carlo
- MRS
- magnetic resonance spectroscopy
- NAA
- N-acetyl-aspartate
- NMR
- nuclear magnetic resonance
- ppm
- part per million
- R2B
- ratio to the best
- SD
- standard deviation
- SNR
- signal to noise ratio
- SNRe
- equivalent signal to noise ratio
- TA/σ
- weighted average temperature using weighting factor A/σ
- Tc
- combined or average temperature
- TNAA
- temperature measured using NAA as a reference
- δ
- frequency in ppm
- σe
- equivalent noise