Background High incidence of life-threatening thrombotic complications is observed in severely ill COVID-19 patients. D-dimer may help evaluate disease severity and predict outcomes at hospital admission. However, its non-specificity and long analysis times strongly constrain its clinical value. Viscoelastic tests (VET) are widely available rapid point-of-care devices that have been shown to detect a hypercoagulable state (increased clot stiffness and fibrinolysis shutdown) as major contributors of the thrombotic complication in COVID-19. Nevertheless, based on the data obtained so far, definitive conclusions have not been drawn.
Objectives We aim to evaluate the association between VET parameters, standard coagulation tests and inflammation markers assessed in COVID-19 patients at hospital admission with disease severity and outcomes.
Patients/Methods A total of 69 COVID-19 patients requiring hospitalization were included in the study. The pro-inflammatory and pro-thrombotic state was analyzed by a panel of inflammation markers (IL-6, CRP, LDH, ferritin), routine coagulation tests (PT, aPTT, platelet count, fibrinogen, D-dimer) and a SEER sonorheometry VET profile (Quantra® System).
Results Inflammatory markers IL-6, CRP, LDH and ferritin were elevated in a high percentage of patients (73.6%, 89.2%, 57.1% and 52.4%), as were coagulation-related parameters such as fibrinogen (81.4%) and D-dimer levels (66.2%). Quantra® analysis revealed increased clot stiffness (CS) in 34.8%, particularly due to increased fibrinogen contribution (FCS) in 63.7%. Increased clot stability to lysis (CSL) was observed in 32.4%. Age > 65 years, elevated values of fibrinogen, D-dimer, LDH, increased clot stiffness and resistance to clot lysis were significantly associated with worsening disease. The Quantra® FCS parameter showed a particularly high prognostic value in distinguishing patients with severe symptomatology.
Conclusion The global study of hemostasis by the whole blood point-of-care Quantra® VET system may be a powerful tool for identifying poor prognosis in COVID-19 patients at hospital admission. In particular, FCS measured by Quantra® could be established as a plausible prognostic marker to aid the clinical management of COVID-19 patients.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
No external funding was received
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
local ethical committee (Instituto de Investigacion Biomedica de Malaga - IBIMA).
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
No data in external datasets