Abstract
Background context Traumatic thoracolumbar (TL) fractures are frequently encountered in emergency rooms. Sagittal and anteroposterior radiographs are the first step in the trauma routine imaging. Up to 30% of TL fractures are missed in this imaging modality, thus requiring a CT and/or MRI to confirm the diagnosis. A delay in treatment leads to increased morbidity, mortality, exposure to ionizing radiation and financial burden. Fracture detection with Machine Learning models has achieved expert level performance in previous studies. Reliably detecting vertebral fractures in simple radiographic projections would have a significant clinical and financial impact.
Purpose To develop a deep learning model that detects traumatic fractures on sagittal radiographs of the TL spine.
Study design/setting Retrospective Cohort study.
Methods We collected sagittal radiographs, CT and MRI scans of the TL spine of 362 patients exhibiting traumatic vertebral fractures. Cases were excluded when CT and/or MRI where not available. The reference standard was set by an expert group of three spine surgeons who conjointly annotated the sagittal radiographs of 171 cases. CT and/or MRI were reviewed to confirm the presence and type of the fracture in all cases. 302 cropped vertebral images were labelled ‘fracture’ and 328 ‘no fracture’. After augmentation, this dataset was then used to train, validate, and test deep learning classifiers based on ResNet18 and VGG16 architectures. To ensure that the model’s prediction was based on the correct identification of the fracture zone, an Activation Map analysis was conducted.
Results Vertebras T12 to L2 were the most frequently involved, accounting for 48% of the fractures. A4, A3 and A1 were the most frequent AO Spine fracture types. Accuracies of 88% and 84% were obtained with ResNet18 and VGG16 respectively. The sensitivity was 89% with both architectures but ResNet18 showed a higher specificity (88%) compared to VGG16 (79%). The fracture zone was precisely identified in 81% of the heatmaps.
Conclusions Our AI model can accurately identify anomalies suggestive of vertebral fractures in sagittal radiographs by precisely identifying the fracture zone within the vertebral body.
Clinical significance Clinical implementation of a diagnosis aid tool specifically trained for TL fracture identification is anticipated to reduce the rate of missed vertebral fractures in emergency rooms.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study was partially financed by the AO Foundation, Davos, Switzerland
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The Ethical Committee approval was granted via the Comitato Etico Milano Area 3 under the Ref. No. 359-24062020.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Financial Disclosure: This study was performed with the assistance of the AO Foundation.
Data Availability
The data that support the findings of this study are available from the corresponding author, GSR, upon reasonable request.