Thermal Camera Detection of High Temperature for Mass COVID Screening

Richard S. Maguire, Matt Hogg, Iain D. Carrie, Maria Blaney, Antonin Couturier, Lucy Longbottom, Jack Thomson, Aimee Thompson, Craig Warren, David J. Lowe
doi: https://doi.org/10.1101/2021.05.05.21256285
Richard S. Maguire
1Electro-Optics and Algorithms Engineer with Thales UK Ltd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: iain.carrie@uk.thalesgroup.com
Matt Hogg
2Algorithms Engineer with Thales UK Ltd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Iain D. Carrie
3Algorithms Expert and Chief Autonomy Technologist with Thales UK Ltd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: iain.carrie@uk.thalesgroup.com
Maria Blaney
4Clinical Fellow Emergency Medicine with Queen Elizabeth University Hospital NHS Greater Glasgow and Clyde
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Antonin Couturier
5Senior Data Scientist with Thales UK Ltd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lucy Longbottom
6Emergency Department Queen Elizabeth University Hospital NHS Greater Glasgow and Clyde
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jack Thomson
6Emergency Department Queen Elizabeth University Hospital NHS Greater Glasgow and Clyde
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Aimee Thompson
6Emergency Department Queen Elizabeth University Hospital NHS Greater Glasgow and Clyde
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Craig Warren
6Emergency Department Queen Elizabeth University Hospital NHS Greater Glasgow and Clyde
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David J. Lowe
7Consultant Emergency Medicine with Queen Elizabeth University Hospital NHS Greater Glasgow and Clyde
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

The COVID-19 [SARS-COV-2] pandemic has had a devastating global impact, with both the human and socio economic costs being severe. One result of the COVID-19 pandemic is the emergence of an urgent requirement for effective techniques and technologies for screening individuals showing symptoms of infection in a non-invasive and non-contact way. Systems that exploit thermal imaging technology to screen individuals show promise to satisfy the desired criteria, including offering a non-contact, non-invasive method of temperature measurement. Furthermore, the potential for mass and passive screening makes thermal imaging systems an attractive technology where current ‘standard of care’ methods are not practical.

Critically, any fever screening solution must be capable of accurate temperature measurement and subsequent prediction of core temperature. This is essential to ensure a high sensitivity in identifying fever while maintaining a low rate of false positives. This paper discusses the results and analysis of a clinical trial undertaken by Thales UK Ltd and the Queen Elizabeth University Teaching Hospital in Glasgow to assess the accuracy and operation of the High Temperature Detection (HTD) system developed by Thales UK Ltd when used in a clinical setting.

Results of this single centre prospective observational cohort study show that the measured laboratory accuracy of the Thales HTD system (RMSE=0.1°C) is comparable to the accuracy when used in a clinical setting (RMSE = 0.15°C) when measuring a calibrated blackbody source at typical skin temperature. For measurement of forehead skin temperature, the system produced results commensurate with close contact measurement methods (R = 0.86, Mean error=0.05°C).. Compared to measured tympanic temperatures, measurement of the forehead skin temperature by the HTD system showed a moderate correlation (R = 0.43),), which is stronger than close contact IR forehead thermometers (R = 0.20,0.35) An improved correlation was observed between the maximum facial temperature measured by the HTD system and measured tympanic temperatures (R = 0.53), which is significantly stronger than the close contact methods. A linear predictive model for tympanic temperature based on the measured maximum facial temperatures resulted in a root mean square error (RMSE = 0.50°C) that is marginally larger than what is expected as a compound of errors in the measuring devices (RMSE=0.45°C).

The study demonstrates that the HTD could be applied in the clinical and non-clinical setting as a screening mechanism to detect citizens with raised temperature. This approach would enable high volume surveillance and identification of individuals that contribute to further spread of COVID-19. Deployment of the HTD system could be implemented as part of a screening tool to support measures to enhance public safety and confidence in areas of high throughput, such as airports, shopping centres or places of work.

  • Thermal Imaging
  • Fever Screening
  • Thermography
  • Temperature Measurement
  • COVID 19

Competing Interest Statement

Thales UK Ltd the designers of HTD camera used in study. The institution of several authors Thales UK Ltd funded the study in partnership with Thales Digital Identity and Security (another Thales Subsidiary) who are working with Thales UK Ltd to deploy the HTD system in numerous applications. Novel and inventive aspects of the HTD system are currently under application for [UK Patent Application No 2011944.2]

Clinical Trial

NCT04792450

Funding Statement

Thales UK Ltd the designers of HTD camera used in study. The institution of several authors Thales UK Ltd funded the study in partnership with Thales Digital Identity and Security (another Thales Subsidiary) who are working with Thales UK Ltd to deploy the HTD system in numerous applications.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Ethical approval was granted by Camden & Kings Cross Research and Ethics Committee (20/HRA/4413).

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • This work was supported by Thales UK Ltd; NHS Greater Glasgow and Clyde and Enterprise Scotland

  • This study was conceived by: Richard Maguire; Dr David J. Lowe; Dr Iain D. Carrie; Matt Hogg and Antonin Couturier. Dr Craig Warren; Dr Aimee Thompson; Lucy Longbottom; Dr Maria Blaney and Jack Thomson contributed to data collection and earlier user feedback during initial testing. All parties contributed to writing and subsequent revisions of the manuscript.

  • Dr Iain D. Carrie acts as technical guarantor for this study whilst Dr David J. Lowe acts as clinical Guarantor for this study.

  • 1 It is expected as per Gauss-Markov theorem that the linear model is the best performing, the rescaling gives an example of intuitive model (the distribution of forehead temperature is transformed to match the one of tympanic temperature) and compares its performance to the best simple model

Data Availability

No external data was used in the preparation of the manuscript. All trials measurements and data is held by Thales in accordance with the requirements of the Trial and GDPR. All patient consent forms are held and archived by the Queen Elizabeth University Hospital in accordance with the requirements of the trial and GDPR.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted May 07, 2021.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Thermal Camera Detection of High Temperature for Mass COVID Screening
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Thermal Camera Detection of High Temperature for Mass COVID Screening
Richard S. Maguire, Matt Hogg, Iain D. Carrie, Maria Blaney, Antonin Couturier, Lucy Longbottom, Jack Thomson, Aimee Thompson, Craig Warren, David J. Lowe
medRxiv 2021.05.05.21256285; doi: https://doi.org/10.1101/2021.05.05.21256285
Digg logo Reddit logo Twitter logo Facebook logo Google logo LinkedIn logo Mendeley logo
Citation Tools
Thermal Camera Detection of High Temperature for Mass COVID Screening
Richard S. Maguire, Matt Hogg, Iain D. Carrie, Maria Blaney, Antonin Couturier, Lucy Longbottom, Jack Thomson, Aimee Thompson, Craig Warren, David J. Lowe
medRxiv 2021.05.05.21256285; doi: https://doi.org/10.1101/2021.05.05.21256285

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (179)
  • Allergy and Immunology (431)
  • Anesthesia (99)
  • Cardiovascular Medicine (943)
  • Dentistry and Oral Medicine (178)
  • Dermatology (109)
  • Emergency Medicine (260)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (420)
  • Epidemiology (8971)
  • Forensic Medicine (4)
  • Gastroenterology (418)
  • Genetic and Genomic Medicine (1938)
  • Geriatric Medicine (190)
  • Health Economics (400)
  • Health Informatics (1323)
  • Health Policy (657)
  • Health Systems and Quality Improvement (517)
  • Hematology (212)
  • HIV/AIDS (416)
  • Infectious Diseases (except HIV/AIDS) (10772)
  • Intensive Care and Critical Care Medicine (571)
  • Medical Education (200)
  • Medical Ethics (54)
  • Nephrology (221)
  • Neurology (1819)
  • Nursing (108)
  • Nutrition (271)
  • Obstetrics and Gynecology (351)
  • Occupational and Environmental Health (469)
  • Oncology (992)
  • Ophthalmology (296)
  • Orthopedics (111)
  • Otolaryngology (182)
  • Pain Medicine (126)
  • Palliative Medicine (44)
  • Pathology (265)
  • Pediatrics (576)
  • Pharmacology and Therapeutics (275)
  • Primary Care Research (234)
  • Psychiatry and Clinical Psychology (1892)
  • Public and Global Health (4111)
  • Radiology and Imaging (674)
  • Rehabilitation Medicine and Physical Therapy (364)
  • Respiratory Medicine (548)
  • Rheumatology (224)
  • Sexual and Reproductive Health (190)
  • Sports Medicine (177)
  • Surgery (207)
  • Toxicology (38)
  • Transplantation (109)
  • Urology (80)