Abstract
For the control of immunity in COVID-19 survivors and vaccinated subjects there is an urgent need for reliable and rapid serological assays.
Based on samples from 63 COVID-19 survivors up to seven months after symptom onset, and on 50 serum samples taken before the beginning of the pandemic, we compared the performance of three commercial immunoassays for the detection of SARS-CoV-2 IgA and IgG antibodies (Euroimmun SARS-COV-2 IgA/IgG, Mikrogen recomWell SARS-CoV-2 IgA/IgG, and SERION ELISA agile SARS-CoV-2 IgA/IgG) and three rapid lateral flow (immunochromatographic) tests (Abbott Panbio COVID-19 IgG/IgM, NADAL COVID-19 IgG/IgM, and Cleartest Corona 2019-nCOV IgG/IgM) with a plaque-reduction neutralization test (PRNT50) representing the gold standard. In addition, we report and validate a novel, non-commercial flow cytometry bead-based surrogate test.
57 out of 63 PCR-confirmed COVID-19 patients (90 %) showed neutralizing antibodies. The sensitivity of the seven assays ranged from 7.0 % to 98.3 %, the specificity from 86.0 % to 100.00 %. Only one commercial immunoassay showed a sensitivity and specificity of greater than 98 %. These data indicate abundant interassay variability.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study was funded by the Federal Ministry for Education and Science (BMBF) within the program InfectControl (project COVMon, grant-No 03COV26A) and the Free State of Bavaria with COVID-research funds provided to the University of Wuerzburg, Germany.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethics Committee University Hospital Wuerzburg
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
The data shown in the manuscript is available upon request from the corresponding author.