Correction of measurement error in a commercial multiple-breath washout device

View ORCID ProfileFlorian Wyler, View ORCID ProfileMarc-Alexander Oestreich, View ORCID ProfileBettina S. Frauchiger, View ORCID ProfileKathryn Ramsey, View ORCID ProfilePhilipp Latzin
doi: https://doi.org/10.1101/2021.02.06.21251250
Florian Wyler
1Pediatric Respiratory Medicine, Inselspital, University Children’s Hospital of Bern, University of Bern, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Florian Wyler
Marc-Alexander Oestreich
1Pediatric Respiratory Medicine, Inselspital, University Children’s Hospital of Bern, University of Bern, Switzerland
2Graduate School for Health Sciences, University of Bern, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Marc-Alexander Oestreich
Bettina S. Frauchiger
1Pediatric Respiratory Medicine, Inselspital, University Children’s Hospital of Bern, University of Bern, Switzerland
3Graduate School of Cellular and Biomedical Sciences, University of Bern, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Bettina S. Frauchiger
Kathryn Ramsey
1Pediatric Respiratory Medicine, Inselspital, University Children’s Hospital of Bern, University of Bern, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Kathryn Ramsey
Philipp Latzin
1Pediatric Respiratory Medicine, Inselspital, University Children’s Hospital of Bern, University of Bern, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Philipp Latzin
  • For correspondence: philipp.latzin@insel.ch
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Rationale Nitrogen multiple-breath washout (N2MBW) is an established technique to assess functional residual capacity (FRC) and ventilation inhomogeneity in the lung. Accurate measurement of gas concentrations is essential for the appropriate calculation of clinical outcomes.

Objectives We investigated the accuracy of oxygen and carbon dioxide measurements used for the indirect calculation of nitrogen concentration in a commercial MBW device (Exhalyzer D, Eco Medics AG, Duernten, Switzerland) and its impact on FRC and lung clearance index (LCI).

Methods High precision calibration gas mixtures and mass spectrometry were used to evaluate sensor output. We assessed the impact of corrected signal processing on FRC and LCI in a dataset of healthy children and children with cystic fibrosis using custom analysis software.

Results We found inadequate correction for the cross sensitivity of the oxygen and carbon dioxide sensors in the Exhalyzer D device. This results in an overestimation of expired nitrogen concentration, and consequently FRC and LCI outcomes. Breath-by-breath correction of this error reduced mean (SD) FRC by 8.9 (2.2)% and LCI by 11.9 (4.0)%. It also resulted in almost complete disappearance of the tissue nitrogen signal at the end of measurements.

Conclusions Inadequate correction for cross sensitivity between the oxygen and carbon dioxide gas sensors of the Exhalyzer D device leads to an overestimation of FRC and LCI. Correction of this error is possible and could be applied by re-analysing the measurements breath-by-breath in an updated software version.

Grants, Gifts, Equipment, Drugs Eco Medics AG (Duernten, Switzerland) provided a research version of their commercial software Spiroware 3.2.1 including insight on signal processing algorithms and helped with the acquisition of mass spectrometry measurements. This project was funded by the Swiss National Science Foundation, Grant Nr. 182719 (P. Latzin) and 168173 (K. Ramsey)

Competing Interest Statement

All authors are in regular contact with manufacturers of multiple breath washout (MBW) devices including Ecomedics AG (Duernten, Switzerland). The authors contacted Ecomedics AG in the process of this study to obtain further information on current signal processing and algorithms for the computation of MBW outcomes and present results. There were no changes to the manuscript by the Ecomedics AG.The authors declare no conflict of interest. Prof. Latzin: personal fees from Vertex, Novartis, Roche, Polyphor, Vifor, Gilead, Schwabe, Zambon, Santhera, grants from Vertex, all outside this work. All other authors declare no conflicts of interest.

Funding Statement

This project was funded by the Swiss National Science Foundation, Grant Nr. 182719 (P. Latzin) and 168173 (K. Ramsey).

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The Ethics Committee of the Canton of Bern, Switzerland approved the study protocol (PB_2017-02139).

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • Title and abstract revised.

Data Availability

Due to the nature of this research, participants of this study did not agree for their data to be shared publicly, so supporting data is not available.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted February 12, 2021.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Correction of measurement error in a commercial multiple-breath washout device
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Correction of measurement error in a commercial multiple-breath washout device
Florian Wyler, Marc-Alexander Oestreich, Bettina S. Frauchiger, Kathryn Ramsey, Philipp Latzin
medRxiv 2021.02.06.21251250; doi: https://doi.org/10.1101/2021.02.06.21251250
Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
Citation Tools
Correction of measurement error in a commercial multiple-breath washout device
Florian Wyler, Marc-Alexander Oestreich, Bettina S. Frauchiger, Kathryn Ramsey, Philipp Latzin
medRxiv 2021.02.06.21251250; doi: https://doi.org/10.1101/2021.02.06.21251250

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Respiratory Medicine
Subject Areas
All Articles
  • Addiction Medicine (70)
  • Allergy and Immunology (168)
  • Anesthesia (50)
  • Cardiovascular Medicine (451)
  • Dentistry and Oral Medicine (83)
  • Dermatology (55)
  • Emergency Medicine (157)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (191)
  • Epidemiology (5258)
  • Forensic Medicine (3)
  • Gastroenterology (195)
  • Genetic and Genomic Medicine (757)
  • Geriatric Medicine (80)
  • Health Economics (213)
  • Health Informatics (698)
  • Health Policy (358)
  • Health Systems and Quality Improvement (224)
  • Hematology (99)
  • HIV/AIDS (163)
  • Infectious Diseases (except HIV/AIDS) (5872)
  • Intensive Care and Critical Care Medicine (362)
  • Medical Education (104)
  • Medical Ethics (25)
  • Nephrology (83)
  • Neurology (764)
  • Nursing (43)
  • Nutrition (130)
  • Obstetrics and Gynecology (142)
  • Occupational and Environmental Health (233)
  • Oncology (479)
  • Ophthalmology (152)
  • Orthopedics (39)
  • Otolaryngology (95)
  • Pain Medicine (39)
  • Palliative Medicine (20)
  • Pathology (141)
  • Pediatrics (223)
  • Pharmacology and Therapeutics (136)
  • Primary Care Research (96)
  • Psychiatry and Clinical Psychology (862)
  • Public and Global Health (2012)
  • Radiology and Imaging (348)
  • Rehabilitation Medicine and Physical Therapy (158)
  • Respiratory Medicine (285)
  • Rheumatology (94)
  • Sexual and Reproductive Health (74)
  • Sports Medicine (76)
  • Surgery (109)
  • Toxicology (25)
  • Transplantation (29)
  • Urology (39)