Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

MICRO-CT Imaging of Thiel-Embalmed and Iodine-Stained Human Temporal Bone for 3D Modeling

Halm Sebastian, Haberthuer David, Eppler Elisabeth, Djonov Valentin, Arnold Andreas
doi: https://doi.org/10.1101/2020.12.15.20247536
Halm Sebastian
1Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
Roles: Dr. med.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: sebastian.halm@ana.unibe.ch
Haberthuer David
1Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
Roles: Dr. phil. nat.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eppler Elisabeth
1Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
Roles: PD Dr. med.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Djonov Valentin
1Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
Roles: Prof. Dr. med.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arnold Andreas
2University of Bern, Hochschulstrasse 6, 3012 Bern, Switzerland
3Department of ENT, Spital Münsingen, Krankenhausweg 18/20, 3110 Münsingen
Roles: Prof. Dr. med.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

ABSTRACT

OBJECTIVE The following study investigates whether human Thiel-embalmed temporal bones are suitable for generating an accurate and complete data set with micro-computed tomography (micro-CT) and the effect of solid iodine staining for improved visualization and facilitated segmentation of middle ear structures.

METHODS One temporal bone was used to verify the accuracy of the imaging by measuring the stapes digitally on the tomography images and physically under the microscope after removal from the temporal bone. All measurements were compared with literature values.

The contralateral temporal bone was used to evaluate segmentation and 3D modeling after iodine staining and micro-CT scanning.

RESULTS The digital and physical stapes measurements differ up to 0.17 mm and 24% but correlate well with the literature values. Soft tissue structures were visible in the unstained scan. However, iodine staining increased the contrast-to-noise ratio by a factor 3.7 on average. The 3D model depicts all ossicles and soft tissue structures in detail, including the chorda tympani, which was not visible in the unstained scan.

CONCLUSION Micro-CT imaging of Thiel-embalmed temporal bones accurately represents the entire anatomy. Iodine staining considerably increases the contrast of soft tissues, simplifies segmentation and enables detailed 3D modeling of the middle ear, which is suitable for further use as a finite element model (FEM).

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

no external funding was received

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Human cadaveric material was used according to the current Swiss Federal Act on Research in-volving Human Beings (Human Research Act, HRA) (Federal Act on Research involving Human Beings) and the current guidelines of the Swiss Academy of Medical Sciences (https://www.samw.ch). Donors formally consent to the post-mortem use of body parts for re-search purposes. Approval by swissethics was granted (PB_2018-00113).

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

sebastian.halm@ana.unibe.ch

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted December 17, 2020.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
MICRO-CT Imaging of Thiel-Embalmed and Iodine-Stained Human Temporal Bone for 3D Modeling
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
MICRO-CT Imaging of Thiel-Embalmed and Iodine-Stained Human Temporal Bone for 3D Modeling
Halm Sebastian, Haberthuer David, Eppler Elisabeth, Djonov Valentin, Arnold Andreas
medRxiv 2020.12.15.20247536; doi: https://doi.org/10.1101/2020.12.15.20247536
Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
Citation Tools
MICRO-CT Imaging of Thiel-Embalmed and Iodine-Stained Human Temporal Bone for 3D Modeling
Halm Sebastian, Haberthuer David, Eppler Elisabeth, Djonov Valentin, Arnold Andreas
medRxiv 2020.12.15.20247536; doi: https://doi.org/10.1101/2020.12.15.20247536

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Otolaryngology
Subject Areas
All Articles
  • Addiction Medicine (62)
  • Allergy and Immunology (142)
  • Anesthesia (44)
  • Cardiovascular Medicine (408)
  • Dentistry and Oral Medicine (67)
  • Dermatology (47)
  • Emergency Medicine (141)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (171)
  • Epidemiology (4815)
  • Forensic Medicine (3)
  • Gastroenterology (177)
  • Genetic and Genomic Medicine (671)
  • Geriatric Medicine (70)
  • Health Economics (187)
  • Health Informatics (621)
  • Health Policy (314)
  • Health Systems and Quality Improvement (200)
  • Hematology (85)
  • HIV/AIDS (155)
  • Infectious Diseases (except HIV/AIDS) (5282)
  • Intensive Care and Critical Care Medicine (326)
  • Medical Education (91)
  • Medical Ethics (24)
  • Nephrology (73)
  • Neurology (677)
  • Nursing (41)
  • Nutrition (111)
  • Obstetrics and Gynecology (124)
  • Occupational and Environmental Health (203)
  • Oncology (438)
  • Ophthalmology (138)
  • Orthopedics (36)
  • Otolaryngology (88)
  • Pain Medicine (35)
  • Palliative Medicine (15)
  • Pathology (128)
  • Pediatrics (193)
  • Pharmacology and Therapeutics (129)
  • Primary Care Research (84)
  • Psychiatry and Clinical Psychology (769)
  • Public and Global Health (1799)
  • Radiology and Imaging (321)
  • Rehabilitation Medicine and Physical Therapy (138)
  • Respiratory Medicine (255)
  • Rheumatology (86)
  • Sexual and Reproductive Health (69)
  • Sports Medicine (61)
  • Surgery (100)
  • Toxicology (23)
  • Transplantation (28)
  • Urology (37)