Fluctuating High Throughput Serological Assay Results in Recurrent Convalescent Plasma Donors

View ORCID ProfileLarry L. Luchsinger, Shiraz Rehmani, Andrew Opalka, View ORCID ProfileDonna Strauss, Christopher D. Hillyer, View ORCID ProfilePatricia Shi, View ORCID ProfileBruce S. Sachais
doi: https://doi.org/10.1101/2020.10.25.20219147
Larry L. Luchsinger
1Lindsley F. Kimball Research Institute, New York Blood Center, New York, NY, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Larry L. Luchsinger
  • For correspondence: bsachais@nybc.org lluchsinger@nybc.org
Shiraz Rehmani
1Lindsley F. Kimball Research Institute, New York Blood Center, New York, NY, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andrew Opalka
1Lindsley F. Kimball Research Institute, New York Blood Center, New York, NY, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Donna Strauss
1Lindsley F. Kimball Research Institute, New York Blood Center, New York, NY, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Donna Strauss
Christopher D. Hillyer
1Lindsley F. Kimball Research Institute, New York Blood Center, New York, NY, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patricia Shi
1Lindsley F. Kimball Research Institute, New York Blood Center, New York, NY, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Patricia Shi
Bruce S. Sachais
1Lindsley F. Kimball Research Institute, New York Blood Center, New York, NY, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Bruce S. Sachais
  • For correspondence: bsachais@nybc.org lluchsinger@nybc.org
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

The clinical and scientific communities rely on serology testing to analyze the degree of antibody-mediated immunity afforded to recovered patients from SARS-CoV-2 infection. Neutralizing antibodies present in COVID-19 convalescent plasma (CCP) remains a practical therapy to treat COVID-19 patients requiring hospitalization. However, it remains unclear how long antibody levels persist in CCP donors after recovery. An accurate estimation of antibody kinetics in CCP donors provide an important observation to further define the extent of long-term immunity in recovered patient and simultaneously inform CCP collection processes in efforts to improve CCP dosing and therapeutic outcome. In this study, we analyzed 63 donors and measured antibody levels using two high throughput screening assays (HTSA) designed to detect antibodies targeting the spike protein (S1) and nucleocapsid protein (NP) of SARS-CoV-2 and monitored antibody levels between 2-8 consecutive donations. We show that anti-S1 antibody levels, as measured using the Ortho Total Ig HTSA, increased over time in repeat CCP donors while anti-NP antibody levels, as measured using the Abbott IgG HTSA, were unchanged or decreased over time. When we normalized these data, we found that both the absolute levels of anti-S1 antibodies and the ratio between S1 and NP antibodies tends to increase over time. These data have important implications for the convalescent donation process, patient protection from future infection and characterization of the SARS-CoV-2 immune response.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

Donor collection and performance of the HTSA and LFA serological assays was funded through the New York Blood Center and the Rockefeller University.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The New York Blood Center IRB has determined this project does not meet the definition of human subject research under the purview of the IRB according to federal regulations. IRB Reference ID: 1596981-1 IRB Reference Title: COVID19 Convalescent Plasma Serology Testing All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

All raw data is available upon request to the corresponding authors.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted October 27, 2020.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Fluctuating High Throughput Serological Assay Results in Recurrent Convalescent Plasma Donors
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Fluctuating High Throughput Serological Assay Results in Recurrent Convalescent Plasma Donors
Larry L. Luchsinger, Shiraz Rehmani, Andrew Opalka, Donna Strauss, Christopher D. Hillyer, Patricia Shi, Bruce S. Sachais
medRxiv 2020.10.25.20219147; doi: https://doi.org/10.1101/2020.10.25.20219147
Digg logo Reddit logo Twitter logo Facebook logo Google logo LinkedIn logo Mendeley logo
Citation Tools
Fluctuating High Throughput Serological Assay Results in Recurrent Convalescent Plasma Donors
Larry L. Luchsinger, Shiraz Rehmani, Andrew Opalka, Donna Strauss, Christopher D. Hillyer, Patricia Shi, Bruce S. Sachais
medRxiv 2020.10.25.20219147; doi: https://doi.org/10.1101/2020.10.25.20219147

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Infectious Diseases (except HIV/AIDS)
Subject Areas
All Articles
  • Addiction Medicine (216)
  • Allergy and Immunology (495)
  • Anesthesia (106)
  • Cardiovascular Medicine (1096)
  • Dentistry and Oral Medicine (196)
  • Dermatology (141)
  • Emergency Medicine (274)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (500)
  • Epidemiology (9767)
  • Forensic Medicine (5)
  • Gastroenterology (480)
  • Genetic and Genomic Medicine (2308)
  • Geriatric Medicine (222)
  • Health Economics (462)
  • Health Informatics (1559)
  • Health Policy (735)
  • Health Systems and Quality Improvement (603)
  • Hematology (236)
  • HIV/AIDS (503)
  • Infectious Diseases (except HIV/AIDS) (11641)
  • Intensive Care and Critical Care Medicine (617)
  • Medical Education (237)
  • Medical Ethics (67)
  • Nephrology (257)
  • Neurology (2142)
  • Nursing (134)
  • Nutrition (336)
  • Obstetrics and Gynecology (427)
  • Occupational and Environmental Health (517)
  • Oncology (1176)
  • Ophthalmology (364)
  • Orthopedics (128)
  • Otolaryngology (220)
  • Pain Medicine (146)
  • Palliative Medicine (50)
  • Pathology (311)
  • Pediatrics (695)
  • Pharmacology and Therapeutics (300)
  • Primary Care Research (267)
  • Psychiatry and Clinical Psychology (2180)
  • Public and Global Health (4657)
  • Radiology and Imaging (778)
  • Rehabilitation Medicine and Physical Therapy (457)
  • Respiratory Medicine (623)
  • Rheumatology (274)
  • Sexual and Reproductive Health (225)
  • Sports Medicine (210)
  • Surgery (251)
  • Toxicology (43)
  • Transplantation (120)
  • Urology (94)