Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Adapting Lot Quality Assurance Sampling to accommodate imperfect tests: application to COVID-19 serosurveillance in Haiti

View ORCID ProfileIsabel R. Fulcher, Mary Clisbee, Wesler Lambert, Fernet Renand Leandre, Bethany Hedt-Gauthier
doi: https://doi.org/10.1101/2020.09.11.20193052
Isabel R. Fulcher
1Department of Global Health and Social Medicine, Harvard Medical School 641 Huntington Ave, Boston, MA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Isabel R. Fulcher
  • For correspondence: isabel_fulcher@hms.harvard.edu
Mary Clisbee
2Zanmi Lasante Santo 18A, Croix-des-Bouquets, Haïti
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wesler Lambert
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fernet Renand Leandre
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bethany Hedt-Gauthier
5Department of Global Health and Social Medicine, Harvard Medical School Department of Biostatistics, Harvard T.H. Chan School of Public Health 641 Huntington Ave, Boston, MA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Background Lot Quality Assurance Sampling (LQAS), a tool used for monitoring health indicators in low resource settings resulting in “high” or “low” classifications, assumes that determination of the trait of interest is perfect. This is often not true for diagnostic tests, with imperfect sensitivity and specificity. Here, we develop Lot Quality Assurance Sampling for Imperfect Tests (LQAS-IMP) to address this issue and apply it to a COVID-19 serosurveillance study in Haiti.

Development As part of the standard LQAS procedure, the user specifies allowable classification errors for the system, which is defined by a sample size and decision rule. We show that when an imperfect diagnostic test is used, the classification errors are larger than specified. We derive a modified procedure, LQAS-IMP, that accounts for the sensitivity and specificity of a diagnostic test to yield correct classification errors.

Application At Zanmi Lasante health facilities in Haiti, the goal was to assess the prior circulation of COVID-19 among healthcare workers (HCWs) using a limited number of antibody tests. As the COVID-19 antibody tests were known to have imperfect diagnostic accuracy, we used the LQAS-IMP procedure to define valid systems for sampling at eleven hospitals in Haiti.

Conclusions The LQAS-IMP procedure accounts for imperfect sensitivity and specificity in system design; if the accuracy of a test is known, the use of LQAS-IMP extends LQAS to applications for indicators that are based on laboratory tests, such as COVID-19 antibodies.

Key Messages

  • It is imperative to account for the sensitivity and specificity of the diagnostic test in serosurveillance studies.

  • For prevalence estimation and inference, adjustments for imperfect testing properties are available to researchers. However, no adjustments currently exist for the design of Lot Quality Assurance Sampling systems, resulting in invalid classification systems when used with an imperfect diagnostic test.

  • When sensitivity and specificity of a diagnostic test is known, Lot Quality Assurance Sampling for Imperfect Tests should be used to determine the sample size and decision rule for a system as it will result in valid classification errors.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

No external funding was received for this research.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

This work did not require IRB approval.

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

Not applicable

https://github.com/isabelfulcher/lqas_imp

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted September 13, 2020.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Adapting Lot Quality Assurance Sampling to accommodate imperfect tests: application to COVID-19 serosurveillance in Haiti
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Adapting Lot Quality Assurance Sampling to accommodate imperfect tests: application to COVID-19 serosurveillance in Haiti
Isabel R. Fulcher, Mary Clisbee, Wesler Lambert, Fernet Renand Leandre, Bethany Hedt-Gauthier
medRxiv 2020.09.11.20193052; doi: https://doi.org/10.1101/2020.09.11.20193052
Reddit logo Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Adapting Lot Quality Assurance Sampling to accommodate imperfect tests: application to COVID-19 serosurveillance in Haiti
Isabel R. Fulcher, Mary Clisbee, Wesler Lambert, Fernet Renand Leandre, Bethany Hedt-Gauthier
medRxiv 2020.09.11.20193052; doi: https://doi.org/10.1101/2020.09.11.20193052

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Infectious Diseases (except HIV/AIDS)
Subject Areas
All Articles
  • Addiction Medicine (227)
  • Allergy and Immunology (502)
  • Anesthesia (110)
  • Cardiovascular Medicine (1234)
  • Dentistry and Oral Medicine (206)
  • Dermatology (147)
  • Emergency Medicine (282)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (530)
  • Epidemiology (10015)
  • Forensic Medicine (5)
  • Gastroenterology (499)
  • Genetic and Genomic Medicine (2449)
  • Geriatric Medicine (236)
  • Health Economics (479)
  • Health Informatics (1638)
  • Health Policy (751)
  • Health Systems and Quality Improvement (636)
  • Hematology (248)
  • HIV/AIDS (532)
  • Infectious Diseases (except HIV/AIDS) (11862)
  • Intensive Care and Critical Care Medicine (625)
  • Medical Education (252)
  • Medical Ethics (74)
  • Nephrology (268)
  • Neurology (2278)
  • Nursing (139)
  • Nutrition (350)
  • Obstetrics and Gynecology (453)
  • Occupational and Environmental Health (535)
  • Oncology (1245)
  • Ophthalmology (375)
  • Orthopedics (133)
  • Otolaryngology (226)
  • Pain Medicine (155)
  • Palliative Medicine (50)
  • Pathology (324)
  • Pediatrics (729)
  • Pharmacology and Therapeutics (311)
  • Primary Care Research (282)
  • Psychiatry and Clinical Psychology (2280)
  • Public and Global Health (4829)
  • Radiology and Imaging (834)
  • Rehabilitation Medicine and Physical Therapy (490)
  • Respiratory Medicine (651)
  • Rheumatology (283)
  • Sexual and Reproductive Health (237)
  • Sports Medicine (226)
  • Surgery (266)
  • Toxicology (44)
  • Transplantation (125)
  • Urology (99)