ABSTRACT
Introduction A controversy remains worldwide regarding the transmission routes of SARS-CoV-2 in hospital settings. We reviewed the current evidence on the air contamination with SARS-CoV-2 in hospital settings, and the factors associated to the contamination including the viral load and the particles size.
Methods The MEDLINE, Embase, Web of Science databases were systematically interrogated for original English-language articles detailing COVID-19 air contamination in hospital settings between 1 December 2019 and 21 July 2020. This study was conducted in accordance with the PRISMA-ScR guidelines. The positivity rate of SARS-CoV-2 viral RNA and culture were described and compared according to the setting, clinical context, air ventilation system, and distance from patient. The SARS-CoV-2 RNA concentrations in copies per m3 of air were pooled and their distribution were described by hospital areas. Particle sizes and SARS-CoV-2 RNA concentrations in copies or TCID50 per m3 were analysed after categorization of sizes in < 1 µm, 1–4 µm, and > 4 µm.
Results Among 2,034 records identified, 17 articles were included in the review. Overall, 27.5% (68/247) of air sampled from close patients’ environment were positive for SARS-CoV-2 RNA, without difference according to the setting (ICU: 27/97, 27.8%; non-ICU: 41/150, 27.3%; p = 0.93), the distance from patients (< 1 meter: 1/64, 1.5%; 1–5 meters: 4/67, 6%; p = 0.4). In other areas, the positivity rate was 23.8% (5/21) in toilets, 9.5% (20/221) in clinical areas, 12.4% (15/121) in staff areas, and 34.1% (14/41) in public areas. A total of 78 viral cultures were performed in three studies, and 3 (4%) were positive, all from close patients’ environment. The median SARS-CoV-2 RNA concentrations varied from 1.103 copies per m3 (IQR: 0.4.103-9.103) in clinical areas to 9.7.103 (5.1.103-14.3.103) in the air of toilets or bathrooms. The protective equipment removal and patients’ rooms had high concentrations/titre of SARS-CoV-2 with aerosol size distributions that showed peaks in the < 1 µm region, and staff offices in the > 4µm region.
Conclusion In hospital, the air near and away from COVID-19 patients is frequently contaminated with SARSCoV-2 RNA, with however, rare proofs of their viability. High viral loads found in toilet/bathrooms, staff and public hallways suggests to carefully consider these areas.
Competing Interest Statement
None
Funding Statement
The research was funded by the National Institute for Health Research Health Protection Research Unit (NIHR HPRU) in Healthcare Associated Infection and Antimicrobial Resistance at Imperial College London in partnership with Public Health England (PHE). The views expressed are those of the author(s) and not necessarily those of the NHS, the NIHR, the Department of Health or Public Health England. GB has received an Early Career Research Fellowship from the Antimicrobial Research Collaborative at Imperial College London, and acknowledges the support of the Welcome trust. RA is supported by a NIHR Fellowship in knowledge mobilisation. The support of ESRC as part of the Antimicrobial Cross Council initiative supported by the seven UK research councils, and also the support of the Global Challenges Research Fund, is gratefully acknowledged.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
not applicable
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data are available