Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Automated measurement of the foveal avascular zone in healthy eyes on Heidelberg Spectralis Optical Coherence Tomography Angiography

View ORCID ProfileLaura Gutierrez-Benitez, Yolanda Palomino, View ORCID ProfileNoe Casas, Mouafk Asaad
doi: https://doi.org/10.1101/2020.08.06.20169672
Laura Gutierrez-Benitez
1Ophthalmology department. Consorci Sanitari de Terrassa. Terrassa, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Laura Gutierrez-Benitez
  • For correspondence: laura.gutierrez.benitez@gmail.com
Yolanda Palomino
1Ophthalmology department. Consorci Sanitari de Terrassa. Terrassa, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Noe Casas
2Polytechnic University of Catalonia. Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Noe Casas
Mouafk Asaad
1Ophthalmology department. Consorci Sanitari de Terrassa. Terrassa, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

ABSTRACT

Purpose To develop and evaluate an automated method to measure the foveal avascular zone (FAZ) area in healthy eyes on Heidelberg Spectralis Optical Coherence Tomography Angiography (HS-OCTA). This method is referred to as the modified Kanno-Saitama macro (mKSM) and it is an evolution of the original Kanno-Saitama macro (KSM) approach.

Methods This cross-sectional study included 29 eyes of 25 healthy volunteers who underwent HS-OCTA at the macular area twice at the same time. Regardless of the quality of the images, all of them were included. Macular data on the superficial vascular plexus, intermediate capillary plexus and deep capillary plexus were processed by mKSM. The FAZ area was measured twice automatically using the mKSM and KSM and twice manually by two independent examiners.

Results From 174 images, KSM could not measure correctly 31% while mKSM could successfully measure all of them. Intrascan intraclass coefficient ranged from 0,948 to 0,993 for manual measurements and was 1 for mKSM method, which means that mKSM FAZ area value is always the same for the same OCTA image. Despite that the difference between human examiners is smaller than between human examiners and mKSM according to Bland-Altman plots, the scatterplots show a strong correlation between human and automatic measurements. The best results are obtained in intermediate capillary plexus.

Conclusions With mKSM, the automated determination of the FAZ area in HS-OCTA is feasible and less human-dependent. It solves the inability of KSM to measure the FAZ area in suboptimal quality images which are frequent in daily clinical practice. Therefore, the mKSM processing could contribute to our understanding of the three vascular plexuses.

Competing Interest Statement

The authors declare that there is no conflict of interests related to this work. Laura Gutierrez-Benitez has collaborated as a consultant for Alcon Healthcare, S.A. and Bayer Hispania, S.L.

Funding Statement

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Consorci Sanitari de Terrassa Research Ethics Committee

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • Purpose To develop and evaluate an automated method to measure the foveal avascular zone (FAZ) area in healthy eyes on Heidelberg Spectralis Optical Coherence Tomography Angiography (HS-OCTA). This method is referred to as the modified Kanno-Saitama macro (mKSM) and it is an evolution of the original Kanno-Saitama macro (KSM) approach. Methods This cross-sectional study included 29 eyes of 25 healthy volunteers who underwent HS-OCTA at the macular area twice at the same time. Regardless of the quality of the images, all of them were included. Macular data on the superficial vascular plexus, intermediate capillary plexus and deep capillary plexus were processed by mKSM. The FAZ area was measured twice automatically using the mKSM and KSM and twice manually by two independent examiners. Results From 174 images, KSM could not measure correctly 31% while mKSM could successfully measure all of them. Intrascan intraclass coefficient ranged from 0,948 to 0,993 for manual measurements and was 1 for mKSM method, which means that mKSM FAZ area value is always the same for the same OCTA image. Despite that the difference between human examiners is smaller than between human examiners and mKSM according to Bland-Altman plots, the scatterplots show a strong correlation between human and automatic measurements. The best results are obtained in intermediate capillary plexus. Conclusions With mKSM, the automated determination of the FAZ area in HS-OCTA is feasible and less human-dependent. It solves the inability of KSM to measure the FAZ area in suboptimal quality images which are frequent in daily clinical practice. Therefore, the mKSM processing could contribute to our understanding of the three vascular plexuses.

Data Availability

The current study is a cross-sectional study

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted February 08, 2021.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Automated measurement of the foveal avascular zone in healthy eyes on Heidelberg Spectralis Optical Coherence Tomography Angiography
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Automated measurement of the foveal avascular zone in healthy eyes on Heidelberg Spectralis Optical Coherence Tomography Angiography
Laura Gutierrez-Benitez, Yolanda Palomino, Noe Casas, Mouafk Asaad
medRxiv 2020.08.06.20169672; doi: https://doi.org/10.1101/2020.08.06.20169672
Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
Citation Tools
Automated measurement of the foveal avascular zone in healthy eyes on Heidelberg Spectralis Optical Coherence Tomography Angiography
Laura Gutierrez-Benitez, Yolanda Palomino, Noe Casas, Mouafk Asaad
medRxiv 2020.08.06.20169672; doi: https://doi.org/10.1101/2020.08.06.20169672

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Ophthalmology
Subject Areas
All Articles
  • Addiction Medicine (70)
  • Allergy and Immunology (168)
  • Anesthesia (51)
  • Cardiovascular Medicine (453)
  • Dentistry and Oral Medicine (83)
  • Dermatology (55)
  • Emergency Medicine (158)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (191)
  • Epidemiology (5270)
  • Forensic Medicine (3)
  • Gastroenterology (196)
  • Genetic and Genomic Medicine (759)
  • Geriatric Medicine (80)
  • Health Economics (213)
  • Health Informatics (700)
  • Health Policy (360)
  • Health Systems and Quality Improvement (224)
  • Hematology (99)
  • HIV/AIDS (164)
  • Infectious Diseases (except HIV/AIDS) (5889)
  • Intensive Care and Critical Care Medicine (363)
  • Medical Education (105)
  • Medical Ethics (25)
  • Nephrology (83)
  • Neurology (767)
  • Nursing (43)
  • Nutrition (131)
  • Obstetrics and Gynecology (143)
  • Occupational and Environmental Health (234)
  • Oncology (480)
  • Ophthalmology (152)
  • Orthopedics (39)
  • Otolaryngology (95)
  • Pain Medicine (39)
  • Palliative Medicine (20)
  • Pathology (141)
  • Pediatrics (223)
  • Pharmacology and Therapeutics (136)
  • Primary Care Research (98)
  • Psychiatry and Clinical Psychology (864)
  • Public and Global Health (2023)
  • Radiology and Imaging (349)
  • Rehabilitation Medicine and Physical Therapy (158)
  • Respiratory Medicine (287)
  • Rheumatology (94)
  • Sexual and Reproductive Health (74)
  • Sports Medicine (77)
  • Surgery (110)
  • Toxicology (25)
  • Transplantation (29)
  • Urology (39)