ABSTRACT
Objective Synchronising positive pressure inflations with an infant’s own breathing is considered lung protective, but the ventilation patterns within the infant lung during synchronous and asynchronous inflations are unknown. The aim of this study was to describe the regional distribution patterns of tidal ventilation within the lung during mechanical ventilation that is synchronous or asynchronous with an infant’s own breathing effort.
Methods Intubated infants receiving synchronised mechanical ventilation at The Royal Children’s Hospital NICU were studied. During four 10-minute periods of routine care, regional distribution of tidal volume (VT; Electrical Impedance Tomography), delivered pressure and airway flow (Florian Respiratory Monitor) were measured for every inflation. Post hoc, each inflation was then classified as synchronous or asynchronous from video data of the ventilator screen, and the distribution of absolute VT and delivered ventilation characteristics determined.
Results 2749 inflations (2462 synchronous) were analysed in 19 infants; mean (SD) age 28 (30) day, GA 35 (5) weeks. Synchronous inflations were associated with a shorter respiratory cycle (p=0.004) and more homogenous VT (centre of ventilation) along the right (0%) to left (100%) lung plane; 45.3 (8.6)% vs 48.8 (9.4)% (uniform ventilation 46%). The gravity dependent centre of ventilation was a mean (95% CI) 2.1 (−0.5, 4.6)% more towards the dependent lung during synchronous inflations. Tidal ventilation relative to anatomical lung size was more homogenous during synchronised inflations in the dependent lung.
Conclusion Synchronous mechanical ventilator lung inflations generate more gravity dependent lung ventilation and more uniform right to left ventilation than asynchronous inflations.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study is supported by the Victorian Government Operational Infrastructure Support Program (Melbourne, Australia). GD and NS received an MCRI Honours student scholarship. DGT is supported by a National Health and Medical Research Council Clinical Career Development Fellowship (Grant ID 1053889). SenTec AG (Landquart, Switzerland) manufactured custom-built EIT belts for infants. All EIT hardware was purchased by MCRI without any restrictions.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Royal Children's Hospital Human Research Ethics Committee (HREC 36159A)
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Financial Support: This study is supported by the Victorian Government Operational Infrastructure Support Program (Melbourne, Australia). GD and NS received an MCRI Honours student scholarship. DGT is supported by a National Health and Medical Research Council Clinical Career Development Fellowship (Grant ID 1053889). SenTec AG (Landquart, Switzerland) manufactured custom-built EIT belts for infants. All EIT hardware was purchased by MCRI without any restrictions.
Data sharing: Deidentified individual participant data, study protocols and statistical analysis codes are available from three months to 23 years following article publication to researchers who provide a methodologically sound proposal, with approval by an independent review committee (“learned intermediary”). Proposals should be directed to david.tingay{at}mcri.edu.au to gain access. Data requestors will need to sign a data access or material transfer agreement approved by MCRI.
Preprint: A preprint version is available at https://doi.org/10.1101/2020.06.12.20129379 (Medrxiv.org)
The manuscript has been revised following peer-review comments. Table order has been amended with Table 1 now describing the patient population and Table 2 key respiratory function findings.
Data Availability
Deidentified individual participant data, study protocols and statistical analysis codes are available from three months to 23 years following article publication to researchers who provide a methodologically sound proposal, with approval by an independent review committee (learned intermediary). Proposals should be directed to david.tingay{at}mcri.edu.au to gain access. Data requestors will need to sign a data access or material transfer agreement approved by MCRI.
Abbreviations
- CO2
- Carbon Dioxide
- CoVRL
- Centre of Ventilation along the right to left lung plane
- CoVVD
- Centre of Ventilation along the ventral dorsal lung plane
- EIT
- Electrical Impedance Tomography
- FiO2
- Fraction of inspired oxygen
- GA
- Gestational Age
- NICU
- Neonatal Intensive Care Unit PEEP Positive end-expiratory pressure
- PIP
- Positive inflation pressure
- ΔP
- Change in pressure
- ROI
- Region of Interest
- SpO2
- Peripheral oxygen saturation
- VTao
- Tidal volume at the airway opening measured by the Florian Respiratory Function Monitor
- VTEIT