Abstract
Purpose This study assesses the feasibility of deep learning detection and classification of 3 retrievable inferior vena cava filters with similar radiographic appearances and emphasizes the importance of visualization methods to confirm proper detection and classification.
Materials and Methods The fast.ai library with ResNet-34 architecture was used to train a deep learning classification model. A total of 442 fluoroscopic images (N=144 patients) from inferior vena cava filter placement or removal were collected. Following image preprocessing, the training set included 382 images (110 Celect, 149 Denali, 123 Günther Tulip), of which 80% were used for training and 20% for validation. Data augmentation was performed for regularization. A random test set of 60 images (20 images of each filter type), not included in the training or validation set, was used for evaluation. Total accuracy and receiver operating characteristic area under the curve were used to evaluate performance. Feature heatmaps were visualized using guided backpropagation and gradient-weighted class activation mapping.
Results The overall accuracy was 80.2% with mean receiver operating characteristic area under the curve of 0.96 for the validation set (N=76), and 85.0% with mean receiver operating characteristic area under the curve of 0.94 for the test set (N=60). Two visualization methods were used to assess correct filter detection and classification.
Conclusions A deep learning model can be used to automatically detect and accurately classify inferior vena cava filters on radiographic images. Visualization techniques should be utilized to ensure deep learning models function as intended.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The Titan Xp used for this research was donated by NVIDIA Corporation.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
University of Pennsylvania
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data may be available upon request. No external datasets were used.
Abbreviations
- CNN
- convolutional neural network
- EKG
- electrocardiogram
- Grad-CAM
- gradient-weighted class activation mapping
- GBP
- guided backpropagation
- IVC
- inferior vena cava
- ML
- machine learning
- ROC AUC
- receiver operating characteristic area under the curve