Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Glaucoma home-monitoring using a tablet-based visual field test (Eyecatcher): An assessment of accuracy and adherence over six months

View ORCID ProfilePete R. Jones, View ORCID ProfilePeter Campbell, View ORCID ProfileTamsin Callaghan, Lee Jones, View ORCID ProfileDaniel S. Asfaw, David F. Edgar, View ORCID ProfileDavid P. Crabb
doi: https://doi.org/10.1101/2020.05.28.20115725
Pete R. Jones
1Division of Optometry and Visual Sciences, School of Health Science, City, University of London, London, England, EC1V 0HB;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Pete R. Jones
  • For correspondence: Peter.Jones@city.ac.uk
Peter Campbell
1Division of Optometry and Visual Sciences, School of Health Science, City, University of London, London, England, EC1V 0HB;
2Department of Ophthalmology, Guy’s and St Thomas’ NHS Foundation Trust, London, England, SE1 7EH;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Peter Campbell
  • For correspondence: Peter.Jones@city.ac.uk Peter.Campbell@city.ac.uk
Tamsin Callaghan
1Division of Optometry and Visual Sciences, School of Health Science, City, University of London, London, England, EC1V 0HB;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Tamsin Callaghan
  • For correspondence: Peter.Jones@city.ac.uk
Lee Jones
1Division of Optometry and Visual Sciences, School of Health Science, City, University of London, London, England, EC1V 0HB;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: Peter.Jones@city.ac.uk
Daniel S. Asfaw
1Division of Optometry and Visual Sciences, School of Health Science, City, University of London, London, England, EC1V 0HB;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Daniel S. Asfaw
  • For correspondence: Peter.Jones@city.ac.uk
David F. Edgar
1Division of Optometry and Visual Sciences, School of Health Science, City, University of London, London, England, EC1V 0HB;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: Peter.Jones@city.ac.uk
David P. Crabb
1Division of Optometry and Visual Sciences, School of Health Science, City, University of London, London, England, EC1V 0HB;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for David P. Crabb
  • For correspondence: Peter.Jones@city.ac.uk
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Purpose To assess accuracy and adherence of visual field (VF) home-monitoring in a pilot sample of glaucoma patients.

Design Prospective longitudinal observation.

Methods Twenty adults (median 71 years) with an established diagnosis of glaucoma were issued a tablet-perimeter (Eyecatcher), and were asked to perform one VF home-assessment per eye, per month, for 6 months (12 tests total). Before and after home-monitoring, two VF assessments were performed in-clinic using Standard Automated Perimetry (SAP; 4 tests total, per eye).

Results All 20 participants could perform monthly home-monitoring, though one participant stopped after 4 months (Adherence: 98%). There was good concordance between VFs measured at home and in the clinic (r = 0.94, P < 0.001). In 21 of 236 tests (9%) Mean Deviation deviated by more than ±3dB from the median. Many of these anomalous tests could be identified by applying machine learning techniques to recordings from the tablets’ front-facing camera (Area Under the ROC Curve = 0.78). Adding home-monitoring data to 2 SAP tests made 6 months apart reduced measurement error (between-test measurement variability) in 97% of eyes, with mean absolute error more than halving in 90% of eyes. Median test duration was 4.5mins (Quartiles: 3.9−5.2mins). Substantial variations in ambient illumination had no observable effect on VF measurements (r = 0.07, P = 0.320).

Conclusions Home-monitoring of VFs is viable for some patients, and may provide clinically useful data.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This study was funded by a Fight for Sight (UK) project grant (#1854/1855) and by the International Glaucoma Association/College of Optometrists 2019 Award (which is funded by the IGA and administered by the IGA in conjunction with the College of Optometrists). Author DA was supported by the European Union's Horizon 2020 research and innovation program under Marie Sklodowska-Curie grant agreement No. 675033. The funding organizations had no role in the design or conduct of this research.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The study was approved by the Ethics Committee for the School of Health Sciences, City, University of London (#ETH1819-0532), and carried out in accordance with the tenets of the Declaration of Helsinki.

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

Data available upon request.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted June 01, 2020.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Glaucoma home-monitoring using a tablet-based visual field test (Eyecatcher): An assessment of accuracy and adherence over six months
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Glaucoma home-monitoring using a tablet-based visual field test (Eyecatcher): An assessment of accuracy and adherence over six months
Pete R. Jones, Peter Campbell, Tamsin Callaghan, Lee Jones, Daniel S. Asfaw, David F. Edgar, David P. Crabb
medRxiv 2020.05.28.20115725; doi: https://doi.org/10.1101/2020.05.28.20115725
Reddit logo Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Glaucoma home-monitoring using a tablet-based visual field test (Eyecatcher): An assessment of accuracy and adherence over six months
Pete R. Jones, Peter Campbell, Tamsin Callaghan, Lee Jones, Daniel S. Asfaw, David F. Edgar, David P. Crabb
medRxiv 2020.05.28.20115725; doi: https://doi.org/10.1101/2020.05.28.20115725

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Ophthalmology
Subject Areas
All Articles
  • Addiction Medicine (227)
  • Allergy and Immunology (504)
  • Anesthesia (110)
  • Cardiovascular Medicine (1238)
  • Dentistry and Oral Medicine (206)
  • Dermatology (147)
  • Emergency Medicine (282)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (531)
  • Epidemiology (10020)
  • Forensic Medicine (5)
  • Gastroenterology (499)
  • Genetic and Genomic Medicine (2452)
  • Geriatric Medicine (236)
  • Health Economics (479)
  • Health Informatics (1642)
  • Health Policy (752)
  • Health Systems and Quality Improvement (636)
  • Hematology (248)
  • HIV/AIDS (533)
  • Infectious Diseases (except HIV/AIDS) (11864)
  • Intensive Care and Critical Care Medicine (626)
  • Medical Education (252)
  • Medical Ethics (74)
  • Nephrology (268)
  • Neurology (2280)
  • Nursing (139)
  • Nutrition (352)
  • Obstetrics and Gynecology (454)
  • Occupational and Environmental Health (536)
  • Oncology (1245)
  • Ophthalmology (377)
  • Orthopedics (134)
  • Otolaryngology (226)
  • Pain Medicine (157)
  • Palliative Medicine (50)
  • Pathology (324)
  • Pediatrics (730)
  • Pharmacology and Therapeutics (312)
  • Primary Care Research (282)
  • Psychiatry and Clinical Psychology (2280)
  • Public and Global Health (4832)
  • Radiology and Imaging (837)
  • Rehabilitation Medicine and Physical Therapy (491)
  • Respiratory Medicine (651)
  • Rheumatology (285)
  • Sexual and Reproductive Health (238)
  • Sports Medicine (227)
  • Surgery (267)
  • Toxicology (44)
  • Transplantation (125)
  • Urology (99)