Abstract
Background As pathogens such as influenza virus and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can easily cause pandemics, rapid diagnostic tests are crucial for implementing efficient quarantine measures, providing effective treatments to patients, and preventing or containing a pandemic infection. Here, we developed the immunochromatography-NanoSuit® method, an improved immunochromatography method combined with a conventional scanning electron microscope (SEM), which enables observation of immunocomplexes labeled with a colloidal metal.
Methods and Findings The detection ability of our method is comparable to that of real-time reverse transcription-polymerase chain reaction and the detection time is approximately 15 min. Our new immunochromatography-NanoSuit® method suppresses cellulose deformity and makes it possible to easily focus and acquire high-resolution images of gold/platinum labeled immunocomplexes of viruses such as influenza A, without the need for conductive treatment as with conventional SEM. Electron microscopy (EM)-based diagnosis of influenza A exhibited 94% clinical sensitivity (29/31) (95% confidence interval [95%CI]: 78.58–99.21%) and 100% clinical specificity (95%CI: 97.80–100%). EM-based diagnosis was significantly more sensitive (71.2%) than macroscopic diagnosis (14.3%), especially in the lower influenza A-RNA copy number group. The detection ability of our method is comparable to that of real-time reverse transcription-polymerase chain reaction.
Conclusions This simple and highly sensitive quantitative analysis method involving immunochromatography can be utilized to diagnose various infections in humans and livestock, including highly infectious diseases such as COVID-19.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was supported by JST START (grant number 714 [to H.K.]), by JSPS KAKENHI (grant numbers JP17K08784 [to H.K.] and JP18H01869 [to T.H.]), and by AMED (grant number A508 [to H.K.]).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
UMIN-CTR
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
The authors confirm that the data supporting the findings of this study are available within the article
Abbreviations
- EM
- Electron microscopy
- LAMP
- loop-mediated isothermal amplification
- SEM
- scanning electron microscope
- GNP
- gold nanoparticles
- INSM
- immunochromatography-NanoSuit® method
- PCR
- polymerase chain reaction
- rRT-PCR
- real-time reverse transcription-polymerase chain reaction
- IgG
- immunoglobulin G
- IgM
- immunoglobulin M